TBA - NAVSEA TECHNICAL PUBLICATION

T9074-AS-GIB-010/271 Rev 1

2 PERCENT SENSITIVITY LEVEL (2-2T)

COBALT 60

SELENIUM 75

IRIDIUM 192

0.1

0.2

.3 .4 .5 .6 .7.8 1

20

2 3 4 5 6 7 8 10

30 MeV

20 MeV

Maximum Recommended Voltage

3 MeV 4 MeV 5 MeV 6 MeV 8 MeV 10 MeV

Acceptable Region

2 MeV

300 kV 400 kV 500 kV 600 kV 800 kV 1 MeV

Minimum Recommended Voltage

200 kV

100 kV

0.1

0.2

.3 .4 .5 .6 .7.8 1

20

2 3 4 5 6 7 8 10

THICKNESS OF MATERIAL THROUGH WHICH RADIATION MUST PASS (INCHES)

Figure 3-2. Recommended X-ray Voltage Settings and Radioisotope Sources to Be Used with Various Copper-Base and Similar Alloys.

3-18