TBA - NAVSEA TECHNICAL PUBLICATION

T9074-AS-GIB-010/271 Rev 1

Figure 3-11. Examples of T m , T s , and Penetrameter Placement: Single Wall, Weld Reinforcement, Cladding Redeposited Over Weld in Base Metal.

SYMBOLS P = PENETRAMETER Sh = SHIM t = MATERIAL THICKNESS UPON WHICH THE PENETRAMETER IS BASED. t = SPECIMEN THICKNESS FOR GEOMETRIC UNSHARPNESS. t = THICKNESS OF WELD, REINFORCEMENT, AND BACKING RING (IF PRESENT) FOR OFFSET TECHNIQUE SHIM SELECTION. m s s 1

RADIATION (SUPERIMPOSED OR OFFSET TECHNIQUE)

Sh PENETRAMETER* (2% OF 2tm)

P

t s

t m

1

t s

1

t s

t m

FILM

SEE NOTE A

NOTE A. THE FILM SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE OBJECT BEING RADIOGRAPHED.

*2% OF 2t FOR 2-LEVEL, 1% OF 2t FOR 1-LEVEL, AND 4% OF 2t FOR 4-LEVEL RADIOGRAPHY. m m m

Figure 3-12. Examples of T m , T s , and Penetrameter Placement: Double Wall, Double Wall Viewing, Weld Reinforcement and Back-Up Strip.

3-25