Advance Function Setting Parameters Each individual tool encompasses these parameters that can be configured for each preset.
Function
Parameter
Description
The ability to rotate at a low speed to allow the screw to naturally reach the hole through reverse rotation before tightening the screw. Speed (rpm) Rotation speed
Free reverse rotation
Angle (turn)
Rotation angle
The ability to use a Torque higher than the Target torque in a single tightening process due to the absence of thread in the tightening or the absence of holes on the surface. Min torque (unit) Minimum torque
Max torque (unit)
Maximum torque
Thread tapping
Speed (rpm)
Rotation speed
Thread tapping end torque
Torque at the end of the function
Angles start from thread tapping
Measure the ngle again from the start of the function
Initialize and re-measure the angle value measured by detecting where the screw meets the fastening. When the screw is inserted into the fastener, it must be greater than the Free run torque when fastening, and it can be used when the screw is torque separable. Speed (rpm) Rotation speed
Engaging torque detection
Torque (%)
Set what % point of Target torque should be based on.
Angle limit (turn)
Limit number of rotations
Time limit (sec)
Time limit
Angles start from engaging Measure the Angle again from the start of the function.
Ability to add a regular or reverse rotation after the tightening is complete.
Speed (rpm)
Rotation speed
Angle after torque-up
Angle (degree)
Rotation angle
Direction
The direction of rotation
MountzCom III User Manual