Mountz Com III Software Manual

Controller Setting Parameters Each individual tool encompasses a selection of parameters that can be configured.

Model

Parameter

Description

Run time limit/Forward (sec) Run time limit/Reverse (sec) Motor stall time limit (sec) Loosening speed (rpm)

The forward motion timeout Reverse motion timeout

Motor load time-out

Reverse rotational speed.

Acceleration (ms)

Set the acceleration time to target speed Sets the output time of Fastening ok signal

Fastening OK signal out time (ms)

Driver ID

Set the tool's unique ID number

Sets the time when an error occurs that is automatically initialized.

Error display reset time (0.1sec)

Torque calibration (%)

Calibrate Torque

Set the time the Torque remains when the Target torque is reached.

Torque holding time (ms)

Initial torque preset # display when power on

Set Preset that is automatically selected after power on.

Change the model of the Tool Driver model of Driver parameter does not change. Most settings are initialized on change, and rool restarts. Set the maximum torque to use in Free Speed section. The torque can be higher than the target torque. Factory reset settings excluding some when inputting '77'. Enable the tool to be locked automatically depending on the circumstances during use of the Model feature when activated. Set the time the Torque remains when the Target torque is reached. Speed is automatically set according to Target torque when enabled. NG will not be displayed, even if the fastening is incomplete within the specified angle. Enable Model functionality on activation. Error occurs when the tool stops without torque-up during activation.

Driver model

Free speed max torque

Parameters initialize to factory setting

Automatic driver lock (model only)

Torque holding time (ms)

AD

Auto speed by torque setting

Judged fasten minimum turns

Model selection mode

Fastening stop error

Reverse lock

Reverse rotation lock on activation

COM port baudrate

Set the communication speed of the COM port Set Torque's units. Most settings are initialized on change, and the tool restarts. Set the orientation of the screw for each tightening Preset. Check: CCW/Un-Check: CW Set the information displayed on the 7-segments LED in AD.

Torque unit

Screw type

Display segments select

Synchronization

Enable Sync feature on activation When activated, the AD acts as Master

Sync master

Torque synchronization does not occur in the Free Speed section (Step 3), specifically before reaching the Seating Point (Step 3). If any of the screws reach the seating point, it will pause until all screws across all axes reach the seating point. This parameter establishes the maximum waiting time for a screw at the seating point. Synchronized fastening will begin once all the screws arrive at the Seating Point. In the Ramp-Up section (Step

Waiting before sync step (ms)

Waiting between sync step (ms)

MountzCom III User Manual