4), 10 virtual points will be created from where the torque begins to rise until it reaches the maximum (Target Torque). If one of the screws comes to the 1st virtual point first, it will wait until every screw arrives at the 1st virtual point. Once every screw arrives at the 1st virtual point, all screws will go to the next virtual point, and it will repeat until it reaches the 10th virtual point, which will be the point where torque comes to the target torque. This setting sets the maximum time for the first screw, which arrives at the virtual point first, to wait until every screw arrives at each virtual point.
Driver ID
Set the tool's unique ID number
Change the model of the Tool Driver model of Driver parameter does not change. Most settings are initialized on change, and the Tool restarts Set Torque's units. Most settings are initialized on change, and the tool restarts.
Driver model
Torque unit
Password Set the access password for the front LCD menu. Parameters initialize to factory setting Factory reset settings excluding some when inputting '77'. Auto speed by torque setting Speed is automatically set according to Target torque when enabled. Acceleration (ms) Set the acceleration time to target speed. Torque holding time (ms) Set the time the Torque remains when the Target torque is reached. Use max torque for reverse Allow up to torque set during reverse rotation when enabled. Loosening speed (rpm) Reverse rotational speed Run time limit/Forward (sec) The forward motion timeout Run time limit/Reverse (sec) Reverse motion timeout Motor stall time limit (sec) Motor load time-out Error display reset time (0.1sec) Sets the time when an error occurs that is automatically initialized. Fastening OK signal out time (ms) Sets the output time of Fastening ok signal.
EC & ECT
Set the orientation of the screw for each tightening Preset. Check: CCW/Un-Check: CW NG will not be displayed, even if the fastening is incomplete within the specified angle Error occurs when the tool stops without torque-up during activation. Buzzer sound when Error occurs during activation. Calibrate Torque. Switch must be placed in reverse direction to set it up. Prevents the use of the front LCD when deactivated. When activated, reverse rotation is prevented when manual tool is used. The screwdriver is activated by the pulse start signal from the lever, and this operation continues until the torque reaches its target value or an automatic stop is triggered based on the angle in the manual screwdriver mode. Enable or disable the F/R switch, which permits the transition between "F" (Forward) and "R" (Reverse). The driver will exclusively operate in the Forward mode when this option is disabled. Set Preset or Model that is automatically selected after power on.
Screw type
Judged fasten minimum turns
Fastening stop error
Alarm sound control
Torque calibration (%)
Selection on panel
Reverse lock (Handheld only)
Trigger start (Handheld only)
Reverse start (Handheld only)
Preset/Model when power on