Mountz Com III Software Manual

Set the RS232 communication port to MODBUS communication or Barcode communication. Sets the speed of the RS232 communication port. Automatically output tightening information into communication when activated. Select the output port of the tightening information that is automatically output. Set communication protocol to MODBUS or OPEN protocol.

RS-232 select

RS-232 baudrate

Auto data output

Auto data output port

Protocol

Model selection mode

Enable Model functionality on activation. Use front LCD to display Preset or Model.

Preset/Model selection on panel

Start the model with Barcode input in Model mode when activated. Enable the tool to be locked automatically depending on the circumstances during use of the Model feature when activated. Automatically restart when the model is terminated when activated. Sets the output time of the LED embedded in the tool.

Model start by barcode

Automatic driver lock (model only)

Model auto restart

LED on time

Holding time angle limit (degree) (EC and ECT only)

Adjust the driver's turning angle to maintain torque power.

Set the type of tightening information to export to communication. Enable the Crowfoot feature on activation.

Event data select

Crowfoot

Crowfoot ratio

Set the gear ratio of the Crowfoot. Set the efficiency of Crowfoot. Sets the reverse torque of the Crowfoot. Sets the reverse speed of the Crowfoot.

ECT

Crowfoot efficiency (%) Crowfoot reverse torque

Crowfoot reverse speed (rpm)

Screw count

Set the number of tightening.

Change the model of the Tool. Driver model of Driver parameter does not change. Most settings are initialized on change, and the Tool restarts.

Driver model

Torque unit Set Torque's units. Most settings are initialized on change, and the tool restarts. Parameters initialize to factory setting Factory reset settings excluding some when inputting '77'. Auto speed by torque setting Speed is automatically set according to Target torque when enabled. Acceleration (ms) Set the acceleration time to target speed. Torque holding time (ms) Set the time the Torque remains when the Target torque is reached. Loosening speed (rpm) Reverse rotational speed Run time limit/Forward (sec) The forward motion timeout Run time limit/Reverse (sec) Reverse motion timeout Motor stall time limit (sec) Motor load time-out Error display reset time (0.1sec) Sets the time when an error occurs that is automatically initialized.

EPT

Set the orientation of the screw for each tightening Preset. Check: CCWUn-Check:CW NG will not be displayed, even if the fastening is incomplete within the specified angle. Error occurs when the tool stops without torque-up during activation.

Screw type

Judged fasten minimum turns

Fastening stop error

Torque calibration (%)

Calibrate Torque.