Mountz Com III Software Manual

Switch must be placed in reverse direction to set it up.

Reverse control

Set lock state in reverse mode.

Initial torque preset # display when power on

Set Preset that is automatically selected after power on.

Automatically output tightening information into communication when activated.

Auto data output

Automatically lock the tool when the number of tightening reaches the tightening count during activation. Set the amount of time the LED or Light is on. Does not turn off when set to zero. Set the type of data that is stored or exported to the Tool. When activating, you can change Preset using Barcode. The ability to automatically lock the tool after the Wi-fi disconnects for a period.

Auto lock

LED/Light on time (sec)

Select backup data type Preset change by barcode

Driver lock after wi-fi disconnect (sec)

Select display preset number Fastening/Loosening switch type

Set the selectable Preset list on the LCD. Direction of the Fastening/Loosening switch.

Set the tool to enter sleep mode automatically after a set time without any action. Set the tool's lever to delay operation for a set period of time when pressed.

Sleep time (min)

Triggers start delay time (sec)

LCD button lock

Lock the LCD button when activated Enable the Crowfoot feature on activation Set the gear ratio of the Crowfoot Set the efficiency of Crowfoot Sets the reverse torque of the Crowfoot Sets the reverse speed of the Crowfoot

Crowfoot

Crowfoot ratio

EPT

Crowfoot efficiency (%) Crowfoot reverse torque

Crowfoot reverse speed (rpm)

MountzCom III User Manual

28

Made with FlippingBook Annual report maker