Data Fields for Real-Time Monitoring
Group
Data
Description
Index
The index of the data
Time
The time the data was received
Information
Preset
Preset selected when data is generated
Fastening Time
Tightening time
Target torque
Setting Torque when data is generated
Torque
Torque
Converted torque when data occurs
Speed
Tightening speed when data occurs
Angle 3 (1 + 2)
Full tool motion rotation angle when data occurs
Speed/Angle
Snug angle
Angle from snug torque to the end
Angle 1
Angle from motor start to screw seating point
Angle 2
angle from screw seating point to the end
Event data types Other: Others Fastening Complete: Fastening OK Fastening Ng: Fastening NG Direction Change: Forward / Reverse change Preset Change: Preset change AlarmReset: Alarm reset Error Without NG: Error without fastening NG Barcode: Enter Barcode. (EPT only) Screw – 1: Cancel previous tightening.(EPT only)
Status
Status
Direction
Forward/reverse when data occurs.
Remain screw
Number of screws left when data occurred.
Error code
Error code when data is generated.
Barcode
Barcode
Barcode data when data is generated. (AD is not provided)
Start / Stop / Clear for Real-Time Monitoring
A. Start or stop Real-Time monitor. B. During monitoring, no other parameters are read, and warning statements are displayed at the bottom of the Software. C. Select the Auto Saving Data Check Box to collect and save fastening data results automatically.
MountzCom III User Manual
35
Made with FlippingBook Annual report maker