Mountz Com III Software Manual

Data Fields for Real-Time Monitoring

Group

Data

Description

Index

The index of the data

Time

The time the data was received

Information

Preset

Preset selected when data is generated

Fastening Time

Tightening time

Target torque

Setting Torque when data is generated

Torque

Torque

Converted torque when data occurs

Speed

Tightening speed when data occurs

Angle 3 (1 + 2)

Full tool motion rotation angle when data occurs

Speed/Angle

Snug angle

Angle from snug torque to the end

Angle 1

Angle from motor start to screw seating point

Angle 2

angle from screw seating point to the end

Event data types Other: Others Fastening Complete: Fastening OK Fastening Ng: Fastening NG Direction Change: Forward / Reverse change Preset Change: Preset change AlarmReset: Alarm reset Error Without NG: Error without fastening NG Barcode: Enter Barcode. (EPT only) Screw – 1: Cancel previous tightening.(EPT only)

Status

Status

Direction

Forward/reverse when data occurs.

Remain screw

Number of screws left when data occurred.

Error code

Error code when data is generated.

Barcode

Barcode

Barcode data when data is generated. (AD is not provided)

Start / Stop / Clear for Real-Time Monitoring

A. Start or stop Real-Time monitor. B. During monitoring, no other parameters are read, and warning statements are displayed at the bottom of the Software. C. Select the Auto Saving Data Check Box to collect and save fastening data results automatically.

MountzCom III User Manual

35

Made with FlippingBook Annual report maker