Mountz Com III Software Manual

Graph Data

Data

Description

Index

The index of the data.

Time

The time the data was received.

Channel 1

The type of chart on channel 1 when the data is generated.

Channel 2

The type of chart on channel 2 when the data is generated.

Sampling

Graph data sampling interval when data occurs.

Fastening time

Tightening time.

Target torque

Setting Torque when data is generated.

Torque

Converted torque when data occurs.

Speed

Target speed by parameter

Angle 1

Angle from motor start to screw seating point

Angle 2

Angle from screw seating point to the end

Snug angle

Angle from snug torque to the end

Error code

Error code when data is generated

Remain screw

Number of screws left when data occurred

Event data types Other: Others Fastening Complete: Fastening OK Fastening NG: Fastening NG Direction Change: Forward / Reverse change Preset Change: Preset change Alarm Reset: Alarm reset Error Without NG: Error without fastening NG Barcode: Enter Barcode (EPT only) Screw – 1: Cancel previous tightening (EPT only)

Status

Seating torque

torque at the time of sitting on the ECT+

Clamp torque

Result torque for value of clamp torque set on ECT+

Prevailing torque

Average torque in angle interval set on ECT+

Compensation torque

Final torque when using Advanced mode on ECT+

MountzCom III User Manual

38

Made with FlippingBook Annual report maker