Mountz Com III Software Manual

Monitoring Menu Bar

Auto Customize icon

Auto Customize

Press the Auto Customize icon in the top Monitoring Menu Bar.

This function can be applied by calculating speed, free angle, free speed, and speed point values from the currently selected tool's fastening data.

How to Use

A. Select the Preset you want to use and set the Target torque. B. Select joint type. (Soft joint or Hard joint) C. Press the Start button. D. Check the items in the analysis result that change during each tightening while fastening the prepared tightening. E. Press Apply to save if it progressed normally. If it is not the desired setting value, press the Stop button instead of the Apply button to cancel it. F. Checking "Editable" without starting allows you to change the Fastening setting value of the selected Preset.

MountzCom III User Manual

42

Made with FlippingBook Annual report maker