Instrument Reprocessing Guide
Does your Steri-Centre meet SciCan's SPEC ™ s?
LEADERSHIP in Infection Control
Through a sustained legacy of product innovation and refinement, SciCan has set the benchmark for sterilization and instrument reprocessing technology in over 90 countries around the world. Originally founded in 1957, SciCan develops and manufactures highly innovative infection control products that address the need for speed, flexibility, and efficiency in today’s environments. In 1989, SciCan developed and produced an internationally recognized infection control innovation,
the STAT IM ® Cassette Autoclave. Over the next quarter century, SciCan continued to be at the forefront of technology with the release of the HYDR IM ® Instrument Washers, BRAVO ™ Chamber Autoclaves, and G4 Networking Technology. SciCan’s HYDR IM ® , STAT IM ® , BRAVO ™ and STAT CLAVE ™ are designed to be some of the fastest and most efficient instrument washers and autoclaves on the market.
A well designed Steri-Centre should improve Safety , ensure Predictable results, maximize Efficiency , and maintain Compliance . ” “
Safe Dental instruments should be processed in the safest and most efficient way possible to reduce the risk of staff injury and the costs associated with exposure incidents. It is not only important to prevent exposures from sharps, but also from biologically contaminated fluids and aerosols generated by open-lid ultrasonic cleaning and cold sterile solutions. Systems should also be in place to ensure that instruments are safe for use on patients by preventing contamination of instruments after they are processed.
Predictable To avoid delays and interruptions in your clinical workflow, you need to be able to count on having clean, sterile, and dry instruments every time you need them. You also want to be confident that contaminated instruments can flow through the reprocessing steps in your sterilization area quickly and consistently every time. Automation, redundancy, and reliability are the 3 keys to ensuring that this happens.
SCICAN’S STERI-CENTRE SPEC ™ s What are they?
An often overlooked part of many dental offices is the sterilization area, which is the heart of every practice. If instruments can’t efficiently flow into and out of the sterilization area, the rest of the practice will suffer. We have created the “SciCan’s Steri-Centre SPECs” educational campaign, as well as trained Regional Infection Control Trainers nation-wide, to help offices design steri-centres that meet “SciCan’s Steri-Centre SPECs”; meaning that the Steri-Centre will improve Safety, ensure Predictable results, maximize Efficiency, and maintain Compliance. Following SciCan’s Steri-Centre SPECs will help you get the most out of your sterilization area and the equipment you put in it.
Instrument Reprocessing Zones
2 3 Preparation and Packaging
1
4
Receiving, Cleaning, and Decontamination
Sterilization
Sterile Storage
Efficient Speed comes from using processes and equipment that maximize efficiency and reduce manual labour. This applies to the way instruments flow through your office and sterilization area, as well as the equipment you use to reprocess instruments. Manual labour should be eliminated wherever possible so that dental staff can focus on tasks that can’t be automated; such as operatory clean-up and preparation.
Compliant Instrument reprocessing should meet the
manufacturer’s Instructions for Use in accordance with CSA Z314-18, and all your provincial dental guidelines or standards. This not only protects dental staff and their patients, but it also protects the office from costly and reputation-damaging infection control violations. Designing your sterilization area with compliance in mind from the start is the easiest way to make sure that you maintain compliance.
TUTORIAL
WAT TUT
DOWNLOAD BROCHURE
HYDR IM ® G4 Instrument Washers
RE EV
WATCH PRODUCT VIDEO
WAT CAS
REQUEST SAMPLE
HYDR IM G4 automated instrument washing is the first step in the sterilization process.
WATCH TUTORIAL
WAT CAS REA
Efficient The time saved by automated washing compared to manual cleaning is approximately 1 hour of labour for every nine procedural set-ups 1 . HYDR IM G4 cycle times are as fast as 40 minutes from start to dry. HYDR IM G4 ensures that every set of instruments receives the same validated cleaning process. Safe Avoid the many dangerous steps involved with manual washing or using ultrasonic cleaners. Pre-soaking, scrubbing, and drying instruments before sterilization increases the exposure to blood and bodily fluids and the risk of sharps injuries. HYDR IM G4 saves time, money and is a worthy investment for today’s standard of care.
G4 Networking Technology There is nothing like SciCan’s G4 Networking Technology. The large touch screen gives in-depth cycle information and allows users to view current operations. REQUEST SAMPLE From the networking portal, users can access cycle history and validation information. If there is ever a cycle fault, the G4 software will send an email to the office and the service technician, allowing for remote troubleshooting. Large Capacity HYDR IM L110W G4 has a 10 full-size cassette capacity allowing offices to turnover 200 instruments in as little as 44 minutes, start to dry.* HYDR IM C61W G4 has a 6 full-size cassette capacity, allowing offices to turnover 120 instruments in as little as 40 minutes, start to dry.* DOWNLOAD BROCHURE
WAT TUTO
WAT CAS
WAT CAS
Wash Test Indicators (WTIs) Think of it as a routine check-up for your washer The HYDR IM Wash Test Indicators (WTIs) have been designed to provide two-dimensional validation of HYDR IM washing efficacy. It is a simple, easy-to-use indicator that ensures instruments are effectively and consistently cleaned with HIP Cleaning Solution.
1 Tholen, Mark, 10 Ideas to Increase Production and Decrease Expenses in Sterilization. (www.dentaleconomics.com/articles/print/volume-99/issue-10/features/increase-production-and-decrease-expenses-in-sterilization.html) *Actual cycle times will vary with incoming water temperature and pressure.
WAT TUT
DOWNLOAD BROCHURE
RE EV
WATCH PRODUCT VIDEO
WAT CAS
REQUEST SAMPLE
WATCH TUTORIAL
WAT CAS REA
WAT TUTO
DOWNLOAD BROCHURE
WAT CAS
REQUEST SAMPLE
WAT CAS
Instruments Used on Patients
Transport
Store
Optional Pre-Clean or Holding
Sterilize
Rinse
HYDR IM reduces the number of instrument reprocessing steps; increasing efficiency and decreasing sharps exposure risk.
h e
Package
Clean in Ultrasonic
Pat Dry or Air Dry
Rinse
WA TUT
DOWNLOAD BROCHURE
STAT MATIC ™ Ultimate Care System for Handpieces
WA CAS
REQUEST SAMPLE
STAT MATIC automatic care and maintenance system properly cleans, lubricates, and purges up to 3 handpieces prior to sterilization. The STAT MATIC also incorporates a unique chuck cleaner to dislodge debris inside the chuck. You and your staff will profit from greater efficiency, fewer repairs, and extended durability of your handpieces.
WA CAS
Extends the Life of your Handpieces Properly cleans, lubricates, and purges your handpieces to increase their working lifetime.
Optimizes Staff Productivity
Automated process optimizes working procedures in your practice, allowing staff to focus on alternative tasks. Up to 3 handpieces can be cleaned, lubricated, and purged in less than a minute.
Chuck Cleaner Cleans and lubricates the chuck to keep burs from sticking or falling out.
10 Year Warranty Highest quality stainless steel design, long working life – you can rely on STAT MATIC .
WA TUT
DOWNLOAD BROCHURE
STAT CLAVE ™ Cutting Edge Sterilization Technology
WA CAS
REQUEST SAMPLE
STAT CLAVE is a Class B vacuum sterilizer that incorporates both pre-sterilization vacuum to improve steam penetration and post-sterilization vacuum to improve drying. Its 11” chamber and vacuum-assisted closed-door drying efficiently delivers sterilized and dried wrapped instruments.
WA CAS
Fast STAT CLAVE can efficiently turnover wrapped instruments, sterilizing and drying in as little as 38 minutes. Dry Closed-door drying and vacuum technology results in perfectly dried instruments every time. Capacity STAT CLAVE can sterilize up to 4 full-size cassettes and 4 exam cassettes or 20 pouches. G4 Technology SciCan’s G4 equipment can connect and send information to your smart devices so you can have cycle data, instructions, and maintenance notifications at your fingertips.
Gentle Fresh water is used in every cycle, reducing the buildup of oils and debris. Versatile STAT CLAVE offers a number of filling & draining options, including easily accessible and cleanable top reservoirs, front manual fill and a rear automatic fill option that can be connected to the VistaPure water filtration system for automated filling.
RE EV
WATCH PRODUCT VIDEO
WATCH TUTORIAL
REA
WAT TUTO
DOWNLOAD BROCHURE
WAT CASE
REQUEST SAMPLE
WAT CASE
WA TUT
DOWNLOAD BROCHURE
BRAVO ™ Chamber Autoclaves
WA CAS
REQUEST SAMPLE
BRAVO is a Class B fractionated vacuum sterilizer that incorporates both pre-sterilization vacuum to improve steam penetration and post-sterilization vacuum to improve drying.
WA CAS
Fast BRAVO offers the perfect blend of speed and capacity. Total cycle times, including drying, are completed in about half the time of other chamber autoclaves. BRAVO 17V and 21V are two of the fastest chamber autoclaves on the market. They produce consistently dry loads that are sterile and dry in as little as 35 minutes. Gentle The fresh water feature guarantees that fresh water is used with every cycle. Fresh water reduces the build up of oils and debris.
Dry With closed-door drying and vacuum technology, the BRAVO is able to dry faster than other chamber autoclaves. Capacity BRAVO 17V can sterilize 3 full-size cassettes or up to 20 pouches. BRAVO 21V has a deeper chamber and can sterilize 3 oral surgery cassettes or up to 25 pouches.
RE EV
WATCH PRODUCT VIDEO
WATCH TUTORIAL
REA
WAT TUTO
DOWNLOAD BROCHURE
WAT CASE
REQUEST SAMPLE
WAT CASE
WA TUT
DOWNLOAD BROCHURE
STAT IM ® G4 Cassette Autoclaves
WA CAS
REQUEST SAMPLE
STAT IM provides sterilization and dryness at speeds faster than conventional chamber autoclaves.
WA CAS
Fast Cycle Times STAT IM 2000 G4 can complete unwrapped cycles in as little as 6 minutes. Wrapped cycles, including drying, can be completed in 35 minutes. STAT IM 5000 G4 can complete unwrapped cycles in as little as 9 minutes. Wrapped cycles, including drying, can be completed in 40 minutes. Gentle The fresh water feature guarantees fresh water with every cycle. State-of-the-art steam technology is gentle on both solid and hollow instruments. Reliable For over 25 years, STAT IM ’s unmatched speed, reliability, and flexibility have made it one of the world’s best selling tabletop autoclaves.
G4 Networking Technology
SciCan’s G4 equipment can connect and send accurate information to your smart devices so that you can have cycle data, instructions, and maintenance notifications at your fingertips. Capacity STAT IM G4 autoclaves not only offer fast sterilization times but also enough capacity to meet the needs of a busy practice. The STAT IM 2000 G4 capacity allows for up to 4 pouches and the STAT IM 5000 G4 allows for up to 10 pouches.
VistaCool ™ Direct-to-Drain System
VistaCool is a validated, reliable, and maintenance- free solution that safely vents the used sterilization water directly down the drain, eliminating the need for the STAT IM ’s condenser bottle.
RE EV
WATCH PRODUCT VIDEO
WATCH TUTORIAL
REA
WAT TUTO
DOWNLOAD BROCHURE
WAT CASE
REQUEST SAMPLE
WAT CASE
VistaPure ™ Autofill Automatically refill your autoclaves Replenish any new or older-model STAT IM and BRAVO autoclave with distilled- quality water automatically, enabling truly hands-free convenience.
READ EVALUATIONS
WATCH PRODUCT VIDEO
WATCH TUTORIAL
READ STUDIES
VISTAPURE ™ Water Filtration
WATCH TUTORIAL
DOWNLOAD BROCHURE
WATCH CASE STUDY
VISTAPURE is a specialized water filtration system for STAT IM Cassette Autoclaves, BRAVO Fractionated Vacuum Sterilizers, STAT CLAVE G4 Autoclaves, HYDR IM Instrument Washers, ultrasonic cleaners, dental bottles, and other select autoclaves and instrument washers. VISTAPURE provides two grades of high-quality water for ultimate efficiency; one for use in instrument washers and for filling dental bottles and the other for filling autoclaves. The system connects directly to the city water supply and sends filtered water exactly where you need it in the Steri-Centre for easy, on-demand use. REQUEST SAMPLE
WATCH CASE STUDY
Easy to Use VistaPure’s handheld, point-and-shoot wand makes it easy for anyone to fill autoclaves no matter where they’re located. In addition, the system’s mounted faucet makes it easy to fill dental unit bottles over a sink. Convenient VistaPure provides a high volume of ready-to-use water on-demand. Its large 4.25-gallon storage tank means you don’t need to wait for the hyperfiltration process to take place. Consistent Each VistaPure features an in-line TDS meter that monitors water quality and makes it easy to know when it’s time to replace your filters.
DrainHub ™ Multi-port drain adapter The patent-pending device accepts up to eight drain connections in one small hub; saving space, cost, and time.
RE EV
WATCH PRODUCT VIDEO
VistaPure System
WATCH TUTORIAL
REA
WAT TUTO
DOWNLOAD BROCHURE
WAT CASE
REQUEST SAMPLE
WAT CASE
Distilled Quality
Bottle Quality
To Drain
Distilled Quality
Waste
Bottle Quality
VistaPure AutoFill offers an assortment of accessories:
VistaPure AutoFill for STAT IM Deliver distilled-quality water to your STAT IM autoclave automatically. You’ll never have to fill your STAT IM manually again. VistaPure AutoFill for BRAVO and STAT CLAVE Replenish the STAT CLAVE or BRAVO’s refill tank with distilled-quality water automatically—enabling truly hands-free convenience.
WA TUT
DOWNLOAD BROCHURE
EN SURE ™ Monitoring for Steam Sterilization
WA CAS
REQUEST SAMPLE
The EN SURE line of infection control monitoring products ensures your equipment is performing at its peak. It includes a range of products that are simple, easy to use, and help to ensure your patients are being kept safe with every cycle.
WA CAS
Safe Designed to help keep your patients safe with every cycle. Easy Provide the highest level of sterility assurance with easy-to-read indicators, which clearly identify if an instrument load met the expected parameters for sterilization.
Capacity The 10-well incubator allows you to monitor up to 5 sterilizers at one time, providing you with easy-to-read results that show whether sterility has been achieved or not. Reliable Meets the most stringent requirements in today’s changing regulatory environment.
Bowie Dick Test (BD) for Steam Penetration The En sure BD test is designed for steam vacuum assisted autoclaves to ensure proper steam penetration for a confirmed sterilization process. SciCan’s BD test is a unique small form factor test that is easy to use and store. The BD test is available as a starter kit that contains the unique test card holder and 31 test cards.
En sure Chemical Indicators and Integrators
En sure Type 4 and Type 5 indicators are fast and economical solutions for load monitoring. Type 5 integrators are the most accurate of all chemical indicators and contain a chemical ink which reacts to all three sterilization parameters of time, temperature and pressure (steam).
En sure Biological Indicators (BI)
En sure BIs are reliable and self-contained indicators for results in as little as 24 hours. BIs are the only method to ensure effective performance of your sterilizer. The En sure BIs are available in a starter kit system that consists of 25 BIs, the unique incubator, an easy to fill-in log book, and 100 type 5 integrators.
TUTORIAL
WA TUT
DOWNLOAD BROCHURE
OPT IM ® † 33TB One-Step Cleaner & Disinfectant
WA CAS
REQUEST SAMPLE
With a fast broad-spectrum contact time, OPT IM 33TB is one of the most effective cleaner & disinfectants. OPT IM 33TB is safe; it does not require any GHS hazard pictograms, signal words or statements. OPT IM 33TB provides you with confidence that you are compliant and protecting your patients, staff, equipment and the environment; the perfect balance.
WA CAS
Effective One-Step Cleaner Removes organic debris while disinfecting, saving you time and money. 1 Fast Broad-Spectrum Disinfectant 1 minute Tuberculocidal, Virucidal and Bactericidal, and 3 minute Fungicidal contact time ensures compliance. Safe
Sustainable Active ingredient, Hydrogen Peroxide, breaks down into water and oxygen. No active residues reduce environmental impact. Time and Cost Efficient ½ as many wipes as the leading competitor
are needed to keep your surface wet long enough to achieve disinfection. 2 Compatible Designed to be compatible with a wide range of materials. 3
No GHS hazard pictograms, signal words or statements required. No VOCs (volatile organic compounds). Non-toxic.
1 John Molinari, PhD, Peri Nelson, BS, and Devi J.V. Raghavan, BDS. Optim 1 Cleaning and Disinfection Study. Ann Arbor: Dental Advisor, 2016. 2 John A. Molinari, Ph.D., Peri Nelson, B.S., Antonia Molinari. Environmental Surface Wetness Test: Comparison of Disinfectant Wipes. Ann Arbor: Dental Advisor, 2016. 3 John Molinari, Ph.D., Peri Nelson, B.S. Effect of Optim 1 on Tensile Properties of Dental Chair Fabrics. Ann Arbor: Dental Advisor, 2016.
RE EV
WATCH PRODUCT VIDEO
WATCH TUTORIAL
REA
WAT TUTO
DOWNLOAD BROCHURE
1 MINUTE TUBERCULOCIDAL CONTACT TIME REQUEST SAMPLE
WAT CASE
WAT CASE
Active Ingredient: 0.5% Hydrogen Peroxide
Surface Disinfectant Contact Time*
Mycobacteria
Non-enveloped Viruses
Enveloped Viruses
Bacteria
Fungicidal
Product Name
Active Ingredient
HBV (Hep.B)
HCV (Hep.C)
Influenza A
TB
Adeno Polio Noro Rota
RSV
HIV
MRSA VRE E.coli
PSA
Hydrogen Peroxide
1
1
1
1
1
1
1
1
1
1
1
1
3
OPT IM 33TB
10
10
10
10
10
10
10
10
Birex SE
Phenolics
Patterson pdCare
3
2
2
2
2
2
2
3
3
Quats-alcohol
Micro- Kleen 3
3
3
3
3
3
3
3
3
3
3
3
3
Quats-alcohol
1
1
1
1
1
1
1
1
1
1
1
Caviwipes1
Quats-alcohol
3
3
3
3
3
3
3
3
3
Caviwipes
Quats-alcohol
Sanicloth Super
1
2
2
2
2
2
2
2
2
2
2
2
2
Quats-alcohol
3
3
3
3
3
3
3
3
3
3
Germicide 3
Quats-alcohol
Alcohol Anhydrous
5
3
3
Biotext
Alcohol Anhydrous Alcohol Anhydrous
1
20 sec 10 sec
BioSurf
Tb Minuteman Clorox HP Wipes
1
1
1
1
1
1
1
1
Hydrogen Peroxide
5
3
1
30 sec 30 sec 30 sec 30 sec
1
1
30 sec 30 sec 30 sec
5
* Contact time in minutes. If blank, no published information was available. Information was obtained from publicly available material in October of 2016. Information will be updated if there are changes in claims.
NETWORKING Technology
SciCan’s innovative G4 Networking Technology simplifies the way a Steri-Centre is run. It automatically records and monitors every cycle 24/7 so you can operate with the utmost efficiency. It reports human or mechanical error before it costs you time and money.
SciCan’s G4 equipment can connect and send accurate information to your smart devices so that you can have cycle data, instructions, and maintenance notifications at your fingertips.
Accurate Cycle Data Peace of mind knowing cycle data is accurately logged and will remain accessible at any time from any smart phone, tablet, or computer. Remote Technical Support Instant and accurate connection to specialized technicians allows equipment to be remotely supported. Reliable Maintenance reminders and instructions help keep your equipment in good working order. Software Updates Automatic user interface updates to your G4 connected machines.
HYDR IM L110w by
Part Number
Model
Part Number Model VistaPure V3000
STAT IM G4 Autoclaves G4-121106
STAT IM 2000 G4
VistaPure System Complete Recommended Accessories and Spare Parts R3250 2 Year Filter Package R3251 Prefilter Element (Position #1) R3252 Deionization filter (Position #2) R3253 Deionization filter (Position #3) R3254 Hyperfiltration Element (Position #4) R3255 Polishing Filter (Position #5) S9110
G4-201102 STAT IM 5000 G4 Recommended Accessories and Spare Parts 01-115325S STAT IM 2000 Service Kit 01-115326S STAT IM 5000 Service Kit 01-112406S
Cassette Complete STAT IM 2000 G4 Cassette Complete STAT IM 5000 G4 Cassette Seal & Lube Kit STAT IM 2000 Cassette Seal & Lube Kit STAT IM 5000 Air Compressor Filter STAT IM 2000 G4 Air Compressor Filter STAT IM 5000 G4
01-112384S 01-100028S 01-101649S 01-100207S 01-101652S 01-102119S
Optional 2.5 gallon net Storage Capacity Water Tank Optional 4.25 gallon net Storage Capacity Water Tank Optional 9.5 gallon net Storage Capacity Water Tank
S9111 S9113 S3010
Biological Filter STAT IM 2000 G4 and STAT IM 5000 G4
HYDR IM VistaPure Connection
VistaPure AutoFill S3020
STAT CLAVE G4 Chamber Autoclaves G4-621101
VistaPure Autofill - STAT IM VistaPure Autofill - BRAVO
STAT CLAVE G4, 120V, 10A, 60 Hz STAT CLAVE G4, 208V-240V, 12A, 60Hz
G4-622301
S3030
Recommended Accessories and Spare Parts 01-115481S Door Seal 01-115479S Bacteriological Air Filter 01-115478S Chamber Filter Kit (3 Filters) 01-115487S Chamber Rack 01-115482S Wire Instrument Tray 01-115483S Pouch Rack 01-115485S
DrainHub DH154
Drain Hub 4 Hole Drain Hub 8 Hole
DH158
All recommend fittings
DH8200
VistaCool V7501
Tray Extractor with Door Unlock Pin
VistaCool - Single Autoclave System VistaCool - Double Autoclave System VistaCool 3 - Single Autoclave System
Drying plate
01-115484S 01-115374
V7502 V7601
Automatic fill pump
BRAVO Chamber Autoclave M7A310011
STAT MATIC and Spray S30000-NA
BRAVO 17V, 120V, 15A, 60Hz, No Printer
STAT MATIC Recommended Accessories, Spare Parts and Consumables STM500-6NA STAT MATIC Spray S30102 Absorption Pad (6 pack) S30101-BA Maintenance Coupling Bien Air S30101-E Maintenance Coupling E-type S30101-KVH Maintenance Coupling KaVo Intra Head S30101-MW Maintenance Coupling Midwest Slow Speed S30101-CX Maintenance Coupling MULTIflex/Connex S30101-NSK Maintenance Coupling NSK S30101-ST1T Maintenance Coupling Sirona T1 Highspeed S30101-ST1I Maintenance Coupling Sirona T1 Instrument S30101-W&H Maintenance Coupling W&H
BRAVO 17V, 220V, 10A, 60Hz, No Printer, with Datalogger
M7A310013
M7A310014 *Special Order: No Returns or Exchanges
BRAVO 17V, 220V, Datalogger and Printer
BRAVO 21V, 120V, 15A, No Printer, with Datalogger BRAVO 21V, 220V, 10A 60Hz, No Printer, with Datalogger
M7A320011 M7A320013
M7A320012 *Special Order: No Returns or Exchanges M7A320014 *Special Order: No Returns or Exchanges
BRAVO 21V, 120V 20A, 60 Hz, with Printer and Datalogger
BRAVO 21V, 220V, 10A 60Hz, with Printer and Datalogger
Recomended Accessories and Spare Parts 47200010000 Biological Filter 48000050000 Door Gasket STXX0080000 Tray Handle 47200030000 Chamber Drain Filter 01-111774S Water Intake Pull Kit 01-111775S Direct-to-Drain Kit
HYDR IM G4 Instument Washers L110W-D01-G4
HYDR IM L110W G4 Instrument Washer
C61W-D01 HYDR IM C61W G4 Instrument Washer Recommended Accessories, Spare Parts and Consumables CS-HIPL HIP Cleaning Solution for HYDR IM L110W CS-HIPC-U HIP Ultra Solution for HYDR IM C61W 01-113277S Air Filter for HYDR IM C61W WTI-SK Wash Test Indicator (Starter Kit) WTI-RK Wash Test Indicator (Refill Kit) WTI-HOLDER Wash Test Indicator (Holder)
ENSURE SCI-BISK-20 SCI-BINC-120
Ensure BI Starter Kit Ensure Incubator
Ensure BI System Log Book
SCI-BILOG SCI-BI100
Ensure BI’s (100 count refill boxes) Ensure BI’s (25 count refill boxes) Chemical Indicator Strips (250 count)
SCI-BI25
SCI134
Ensure Bowie-Dick Starter Kit Ensure Bowie-Dick Test Cards
SCI-BDSK134V
SCI-BD134V SCI-BDCH
Ensure Bowie-Dick Test Card Holder Ensure Type 5 Integrators (100/bag)
SCI-T5
Ensure Sterilization Pouches
SCI-SCP
VistaPure ™ , VistaPure ™ Autofill, VistaCool ™ and DrainHub ™ are manufactured by:
Manufactured by: SciCan Ltd. 1440 Don Mills Road, Toronto, ON M3B 3P9 Tel: 416-445-1600 Fax: 416-445-2727 Toll free: 1-800-667-7733 customerservice@scican.com
Vista Research Group 1244 County Road 1475 Ashland, OH 44805 USA Tel: (419) 281-3927 VistaResearchGroup.com
† Distributed by: SciCan Ltd. 1440 Don Mills Rd., Toronto, ON M3B 3P9 / Canada Tel: 416 445 1600 Toll free: 1 800 667 7733 customerservice@scican.com
† Manufactured by: Virox Technologies Inc. 2770 Coventry Rd, Oakville, ON Canada, L6H 6R1 Tel: (905) 813-0110
www.scican.com
SD-551 CA EN R2. STAT IM , HYDR IM , and OPT IM are registered trademarks and SciCan SPEC, BRAVO, STAT CLAVE and STAT MATIC are trademarks of SciCan Ltd. VistaCool, VistaPure and DrainHub are trademarks of Vista Research Group.