sd-551 ca en r2-instrument processing-br-FlBo

Instrument Reprocessing Guide

Does your Steri-Centre meet SciCan's SPEC ™ s?

LEADERSHIP in Infection Control

Through a sustained legacy of product innovation and refinement, SciCan has set the benchmark for sterilization and instrument reprocessing technology in over 90 countries around the world. Originally founded in 1957, SciCan develops and manufactures highly innovative infection control products that address the need for speed, flexibility, and efficiency in today’s environments. In 1989, SciCan developed and produced an internationally recognized infection control innovation,

the STAT IM ® Cassette Autoclave. Over the next quarter century, SciCan continued to be at the forefront of technology with the release of the HYDR IM ® Instrument Washers, BRAVO ™ Chamber Autoclaves, and G4 Networking Technology. SciCan’s HYDR IM ® , STAT IM ® , BRAVO ™ and STAT CLAVE ™ are designed to be some of the fastest and most efficient instrument washers and autoclaves on the market.

A well designed Steri-Centre should improve Safety , ensure Predictable results, maximize Efficiency , and maintain Compliance . ” “

Safe Dental instruments should be processed in the safest and most efficient way possible to reduce the risk of staff injury and the costs associated with exposure incidents. It is not only important to prevent exposures from sharps, but also from biologically contaminated fluids and aerosols generated by open-lid ultrasonic cleaning and cold sterile solutions. Systems should also be in place to ensure that instruments are safe for use on patients by preventing contamination of instruments after they are processed.

Predictable To avoid delays and interruptions in your clinical workflow, you need to be able to count on having clean, sterile, and dry instruments every time you need them. You also want to be confident that contaminated instruments can flow through the reprocessing steps in your sterilization area quickly and consistently every time. Automation, redundancy, and reliability are the 3 keys to ensuring that this happens.

SCICAN’S STERI-CENTRE SPEC ™ s What are they?

An often overlooked part of many dental offices is the sterilization area, which is the heart of every practice. If instruments can’t efficiently flow into and out of the sterilization area, the rest of the practice will suffer. We have created the “SciCan’s Steri-Centre SPECs” educational campaign, as well as trained Regional Infection Control Trainers nation-wide, to help offices design steri-centres that meet “SciCan’s Steri-Centre SPECs”; meaning that the Steri-Centre will improve Safety, ensure Predictable results, maximize Efficiency, and maintain Compliance. Following SciCan’s Steri-Centre SPECs will help you get the most out of your sterilization area and the equipment you put in it.

Instrument Reprocessing Zones

2 3 Preparation and Packaging

1

4

Receiving, Cleaning, and Decontamination

Sterilization

Sterile Storage

Efficient Speed comes from using processes and equipment that maximize efficiency and reduce manual labour. This applies to the way instruments flow through your office and sterilization area, as well as the equipment you use to reprocess instruments. Manual labour should be eliminated wherever possible so that dental staff can focus on tasks that can’t be automated; such as operatory clean-up and preparation.

Compliant Instrument reprocessing should meet the

manufacturer’s Instructions for Use in accordance with CSA Z314-18, and all your provincial dental guidelines or standards. This not only protects dental staff and their patients, but it also protects the office from costly and reputation-damaging infection control violations. Designing your sterilization area with compliance in mind from the start is the easiest way to make sure that you maintain compliance.

TUTORIAL

WAT TUT

DOWNLOAD BROCHURE

HYDR IM ® G4 Instrument Washers

RE EV

WATCH PRODUCT VIDEO

WAT CAS

REQUEST SAMPLE

HYDR IM G4 automated instrument washing is the first step in the sterilization process.

WATCH TUTORIAL

WAT CAS REA

Efficient The time saved by automated washing compared to manual cleaning is approximately 1 hour of labour for every nine procedural set-ups 1 . HYDR IM G4 cycle times are as fast as 40 minutes from start to dry. HYDR IM G4 ensures that every set of instruments receives the same validated cleaning process. Safe Avoid the many dangerous steps involved with manual washing or using ultrasonic cleaners. Pre-soaking, scrubbing, and drying instruments before sterilization increases the exposure to blood and bodily fluids and the risk of sharps injuries. HYDR IM G4 saves time, money and is a worthy investment for today’s standard of care.

G4 Networking Technology There is nothing like SciCan’s G4 Networking Technology. The large touch screen gives in-depth cycle information and allows users to view current operations. REQUEST SAMPLE From the networking portal, users can access cycle history and validation information. If there is ever a cycle fault, the G4 software will send an email to the office and the service technician, allowing for remote troubleshooting. Large Capacity HYDR IM L110W G4 has a 10 full-size cassette capacity allowing offices to turnover 200 instruments in as little as 44 minutes, start to dry.* HYDR IM C61W G4 has a 6 full-size cassette capacity, allowing offices to turnover 120 instruments in as little as 40 minutes, start to dry.* DOWNLOAD BROCHURE

WAT TUTO

WAT CAS

WAT CAS

Wash Test Indicators (WTIs) Think of it as a routine check-up for your washer The HYDR IM Wash Test Indicators (WTIs) have been designed to provide two-dimensional validation of HYDR IM washing efficacy. It is a simple, easy-to-use indicator that ensures instruments are effectively and consistently cleaned with HIP Cleaning Solution.

1 Tholen, Mark, 10 Ideas to Increase Production and Decrease Expenses in Sterilization. (www.dentaleconomics.com/articles/print/volume-99/issue-10/features/increase-production-and-decrease-expenses-in-sterilization.html) *Actual cycle times will vary with incoming water temperature and pressure.

WAT TUT

DOWNLOAD BROCHURE

RE EV

WATCH PRODUCT VIDEO

WAT CAS

REQUEST SAMPLE

WATCH TUTORIAL

WAT CAS REA

WAT TUTO

DOWNLOAD BROCHURE

WAT CAS

REQUEST SAMPLE

WAT CAS

Instruments Used on Patients

Transport

Store

Optional Pre-Clean or Holding

Sterilize

Rinse

HYDR IM reduces the number of instrument reprocessing steps; increasing efficiency and decreasing sharps exposure risk.

h e

Package

Clean in Ultrasonic

Pat Dry or Air Dry

Rinse

WA TUT

DOWNLOAD BROCHURE

STAT MATIC ™ Ultimate Care System for Handpieces

WA CAS

REQUEST SAMPLE

STAT MATIC automatic care and maintenance system properly cleans, lubricates, and purges up to 3 handpieces prior to sterilization. The STAT MATIC also incorporates a unique chuck cleaner to dislodge debris inside the chuck. You and your staff will profit from greater efficiency, fewer repairs, and extended durability of your handpieces.

WA CAS

Extends the Life of your Handpieces Properly cleans, lubricates, and purges your handpieces to increase their working lifetime.

Optimizes Staff Productivity

Automated process optimizes working procedures in your practice, allowing staff to focus on alternative tasks. Up to 3 handpieces can be cleaned, lubricated, and purged in less than a minute.

Chuck Cleaner Cleans and lubricates the chuck to keep burs from sticking or falling out.

10 Year Warranty Highest quality stainless steel design, long working life – you can rely on STAT MATIC .

WA TUT

DOWNLOAD BROCHURE

STAT CLAVE ™ Cutting Edge Sterilization Technology

WA CAS

REQUEST SAMPLE

STAT CLAVE is a Class B vacuum sterilizer that incorporates both pre-sterilization vacuum to improve steam penetration and post-sterilization vacuum to improve drying. Its 11” chamber and vacuum-assisted closed-door drying efficiently delivers sterilized and dried wrapped instruments.

WA CAS

Fast STAT CLAVE can efficiently turnover wrapped instruments, sterilizing and drying in as little as 38 minutes. Dry Closed-door drying and vacuum technology results in perfectly dried instruments every time. Capacity STAT CLAVE can sterilize up to 4 full-size cassettes and 4 exam cassettes or 20 pouches. G4 Technology SciCan’s G4 equipment can connect and send information to your smart devices so you can have cycle data, instructions, and maintenance notifications at your fingertips.

Gentle Fresh water is used in every cycle, reducing the buildup of oils and debris. Versatile STAT CLAVE offers a number of filling & draining options, including easily accessible and cleanable top reservoirs, front manual fill and a rear automatic fill option that can be connected to the VistaPure water filtration system for automated filling.

RE EV

WATCH PRODUCT VIDEO

WATCH TUTORIAL

REA

WAT TUTO

DOWNLOAD BROCHURE

WAT CASE

REQUEST SAMPLE

WAT CASE

WA TUT

DOWNLOAD BROCHURE

BRAVO ™ Chamber Autoclaves

WA CAS

REQUEST SAMPLE

BRAVO is a Class B fractionated vacuum sterilizer that incorporates both pre-sterilization vacuum to improve steam penetration and post-sterilization vacuum to improve drying.

WA CAS

Fast BRAVO offers the perfect blend of speed and capacity. Total cycle times, including drying, are completed in about half the time of other chamber autoclaves. BRAVO 17V and 21V are two of the fastest chamber autoclaves on the market. They produce consistently dry loads that are sterile and dry in as little as 35 minutes. Gentle The fresh water feature guarantees that fresh water is used with every cycle. Fresh water reduces the build up of oils and debris.

Dry With closed-door drying and vacuum technology, the BRAVO is able to dry faster than other chamber autoclaves. Capacity BRAVO 17V can sterilize 3 full-size cassettes or up to 20 pouches. BRAVO 21V has a deeper chamber and can sterilize 3 oral surgery cassettes or up to 25 pouches.

RE EV

WATCH PRODUCT VIDEO

WATCH TUTORIAL

REA

WAT TUTO

DOWNLOAD BROCHURE

WAT CASE

REQUEST SAMPLE

WAT CASE

WA TUT

DOWNLOAD BROCHURE

STAT IM ® G4 Cassette Autoclaves

WA CAS

REQUEST SAMPLE

STAT IM provides sterilization and dryness at speeds faster than conventional chamber autoclaves.

WA CAS

Fast Cycle Times STAT IM 2000 G4 can complete unwrapped cycles in as little as 6 minutes. Wrapped cycles, including drying, can be completed in 35 minutes. STAT IM 5000 G4 can complete unwrapped cycles in as little as 9 minutes. Wrapped cycles, including drying, can be completed in 40 minutes. Gentle The fresh water feature guarantees fresh water with every cycle. State-of-the-art steam technology is gentle on both solid and hollow instruments. Reliable For over 25 years, STAT IM ’s unmatched speed, reliability, and flexibility have made it one of the world’s best selling tabletop autoclaves.

G4 Networking Technology

SciCan’s G4 equipment can connect and send accurate information to your smart devices so that you can have cycle data, instructions, and maintenance notifications at your fingertips. Capacity STAT IM G4 autoclaves not only offer fast sterilization times but also enough capacity to meet the needs of a busy practice. The STAT IM 2000 G4 capacity allows for up to 4 pouches and the STAT IM 5000 G4 allows for up to 10 pouches.

VistaCool ™ Direct-to-Drain System

VistaCool is a validated, reliable, and maintenance- free solution that safely vents the used sterilization water directly down the drain, eliminating the need for the STAT IM ’s condenser bottle.

RE EV

WATCH PRODUCT VIDEO

WATCH TUTORIAL

REA

WAT TUTO

DOWNLOAD BROCHURE

WAT CASE

REQUEST SAMPLE

WAT CASE

VistaPure ™ Autofill Automatically refill your autoclaves Replenish any new or older-model STAT IM and BRAVO autoclave with distilled- quality water automatically, enabling truly hands-free convenience.

READ EVALUATIONS

WATCH PRODUCT VIDEO

WATCH TUTORIAL

READ STUDIES

VISTAPURE ™ Water Filtration

WATCH TUTORIAL

DOWNLOAD BROCHURE

WATCH CASE STUDY

VISTAPURE is a specialized water filtration system for STAT IM Cassette Autoclaves, BRAVO Fractionated Vacuum Sterilizers, STAT CLAVE G4 Autoclaves, HYDR IM Instrument Washers, ultrasonic cleaners, dental bottles, and other select autoclaves and instrument washers. VISTAPURE provides two grades of high-quality water for ultimate efficiency; one for use in instrument washers and for filling dental bottles and the other for filling autoclaves. The system connects directly to the city water supply and sends filtered water exactly where you need it in the Steri-Centre for easy, on-demand use. REQUEST SAMPLE

WATCH CASE STUDY

Easy to Use VistaPure’s handheld, point-and-shoot wand makes it easy for anyone to fill autoclaves no matter where they’re located. In addition, the system’s mounted faucet makes it easy to fill dental unit bottles over a sink. Convenient VistaPure provides a high volume of ready-to-use water on-demand. Its large 4.25-gallon storage tank means you don’t need to wait for the hyperfiltration process to take place. Consistent Each VistaPure features an in-line TDS meter that monitors water quality and makes it easy to know when it’s time to replace your filters.

DrainHub ™ Multi-port drain adapter The patent-pending device accepts up to eight drain connections in one small hub; saving space, cost, and time.

RE EV

WATCH PRODUCT VIDEO

VistaPure System

WATCH TUTORIAL

REA

WAT TUTO

DOWNLOAD BROCHURE

WAT CASE

REQUEST SAMPLE

WAT CASE

Distilled Quality

Bottle Quality

To Drain

Distilled Quality

Waste

Bottle Quality

VistaPure AutoFill offers an assortment of accessories:

VistaPure AutoFill for STAT IM Deliver distilled-quality water to your STAT IM autoclave automatically. You’ll never have to fill your STAT IM manually again. VistaPure AutoFill for BRAVO and STAT CLAVE Replenish the STAT CLAVE or BRAVO’s refill tank with distilled-quality water automatically—enabling truly hands-free convenience.

WA TUT

DOWNLOAD BROCHURE

EN SURE ™ Monitoring for Steam Sterilization

WA CAS

REQUEST SAMPLE

The EN SURE line of infection control monitoring products ensures your equipment is performing at its peak. It includes a range of products that are simple, easy to use, and help to ensure your patients are being kept safe with every cycle.

WA CAS

Safe Designed to help keep your patients safe with every cycle. Easy Provide the highest level of sterility assurance with easy-to-read indicators, which clearly identify if an instrument load met the expected parameters for sterilization.

Capacity The 10-well incubator allows you to monitor up to 5 sterilizers at one time, providing you with easy-to-read results that show whether sterility has been achieved or not. Reliable Meets the most stringent requirements in today’s changing regulatory environment.

Bowie Dick Test (BD) for Steam Penetration The En sure BD test is designed for steam vacuum assisted autoclaves to ensure proper steam penetration for a confirmed sterilization process. SciCan’s BD test is a unique small form factor test that is easy to use and store. The BD test is available as a starter kit that contains the unique test card holder and 31 test cards.

En sure Chemical Indicators and Integrators

En sure Type 4 and Type 5 indicators are fast and economical solutions for load monitoring. Type 5 integrators are the most accurate of all chemical indicators and contain a chemical ink which reacts to all three sterilization parameters of time, temperature and pressure (steam).

En sure Biological Indicators (BI)

En sure BIs are reliable and self-contained indicators for results in as little as 24 hours. BIs are the only method to ensure effective performance of your sterilizer. The En sure BIs are available in a starter kit system that consists of 25 BIs, the unique incubator, an easy to fill-in log book, and 100 type 5 integrators.

TUTORIAL

WA TUT

DOWNLOAD BROCHURE

OPT IM ® † 33TB One-Step Cleaner & Disinfectant

WA CAS

REQUEST SAMPLE

With a fast broad-spectrum contact time, OPT IM 33TB is one of the most effective cleaner & disinfectants. OPT IM 33TB is safe; it does not require any GHS hazard pictograms, signal words or statements. OPT IM 33TB provides you with confidence that you are compliant and protecting your patients, staff, equipment and the environment; the perfect balance.

WA CAS

Effective One-Step Cleaner Removes organic debris while disinfecting, saving you time and money. 1 Fast Broad-Spectrum Disinfectant 1 minute Tuberculocidal, Virucidal and Bactericidal, and 3 minute Fungicidal contact time ensures compliance. Safe

Sustainable Active ingredient, Hydrogen Peroxide, breaks down into water and oxygen. No active residues reduce environmental impact. Time and Cost Efficient ½ as many wipes as the leading competitor

are needed to keep your surface wet long enough to achieve disinfection. 2 Compatible Designed to be compatible with a wide range of materials. 3

No GHS hazard pictograms, signal words or statements required. No VOCs (volatile organic compounds). Non-toxic.

1 John Molinari, PhD, Peri Nelson, BS, and Devi J.V. Raghavan, BDS. Optim 1 Cleaning and Disinfection Study. Ann Arbor: Dental Advisor, 2016. 2 John A. Molinari, Ph.D., Peri Nelson, B.S., Antonia Molinari. Environmental Surface Wetness Test: Comparison of Disinfectant Wipes. Ann Arbor: Dental Advisor, 2016. 3 John Molinari, Ph.D., Peri Nelson, B.S. Effect of Optim 1 on Tensile Properties of Dental Chair Fabrics. Ann Arbor: Dental Advisor, 2016.

RE EV

WATCH PRODUCT VIDEO

WATCH TUTORIAL

REA

WAT TUTO

DOWNLOAD BROCHURE

1 MINUTE TUBERCULOCIDAL CONTACT TIME REQUEST SAMPLE

WAT CASE

WAT CASE

Active Ingredient: 0.5% Hydrogen Peroxide

Surface Disinfectant Contact Time*

Mycobacteria

Non-enveloped Viruses

Enveloped Viruses

Bacteria

Fungicidal

Product Name

Active Ingredient

HBV (Hep.B)

HCV (Hep.C)

Influenza A

TB

Adeno Polio Noro Rota

RSV

HIV

MRSA VRE E.coli

PSA

Hydrogen Peroxide

1

1

1

1

1

1

1

1

1

1

1

1

3

OPT IM 33TB

10

10

10

10

10

10

10

10

Birex SE

Phenolics

Patterson pdCare

3

2

2

2

2

2

2

3

3

Quats-alcohol

Micro- Kleen 3

3

3

3

3

3

3

3

3

3

3

3

3

Quats-alcohol

1

1

1

1

1

1

1

1

1

1

1

Caviwipes1

Quats-alcohol

3

3

3

3

3

3

3

3

3

Caviwipes

Quats-alcohol

Sanicloth Super

1

2

2

2

2

2

2

2

2

2

2

2

2

Quats-alcohol

3

3

3

3

3

3

3

3

3

3

Germicide 3

Quats-alcohol

Alcohol Anhydrous

5

3

3

Biotext

Alcohol Anhydrous Alcohol Anhydrous

1

20 sec 10 sec

BioSurf

Tb Minuteman Clorox HP Wipes

1

1

1

1

1

1

1

1

Hydrogen Peroxide

5

3

1

30 sec 30 sec 30 sec 30 sec

1

1

30 sec 30 sec 30 sec

5

* Contact time in minutes. If blank, no published information was available. Information was obtained from publicly available material in October of 2016. Information will be updated if there are changes in claims.

NETWORKING Technology

SciCan’s innovative G4 Networking Technology simplifies the way a Steri-Centre is run. It automatically records and monitors every cycle 24/7 so you can operate with the utmost efficiency. It reports human or mechanical error before it costs you time and money.

SciCan’s G4 equipment can connect and send accurate information to your smart devices so that you can have cycle data, instructions, and maintenance notifications at your fingertips.

Accurate Cycle Data Peace of mind knowing cycle data is accurately logged and will remain accessible at any time from any smart phone, tablet, or computer. Remote Technical Support Instant and accurate connection to specialized technicians allows equipment to be remotely supported. Reliable Maintenance reminders and instructions help keep your equipment in good working order. Software Updates Automatic user interface updates to your G4 connected machines.

HYDR IM L110w by

Part Number

Model

Part Number Model VistaPure V3000

STAT IM G4 Autoclaves G4-121106

STAT IM 2000 G4

VistaPure System Complete Recommended Accessories and Spare Parts R3250 2 Year Filter Package R3251 Prefilter Element (Position #1) R3252 Deionization filter (Position #2) R3253 Deionization filter (Position #3) R3254 Hyperfiltration Element (Position #4) R3255 Polishing Filter (Position #5) S9110

G4-201102 STAT IM 5000 G4 Recommended Accessories and Spare Parts 01-115325S STAT IM 2000 Service Kit 01-115326S STAT IM 5000 Service Kit 01-112406S

Cassette Complete STAT IM 2000 G4 Cassette Complete STAT IM 5000 G4 Cassette Seal & Lube Kit STAT IM 2000 Cassette Seal & Lube Kit STAT IM 5000 Air Compressor Filter STAT IM 2000 G4 Air Compressor Filter STAT IM 5000 G4

01-112384S 01-100028S 01-101649S 01-100207S 01-101652S 01-102119S

Optional 2.5 gallon net Storage Capacity Water Tank Optional 4.25 gallon net Storage Capacity Water Tank Optional 9.5 gallon net Storage Capacity Water Tank

S9111 S9113 S3010

Biological Filter STAT IM 2000 G4 and STAT IM 5000 G4

HYDR IM VistaPure Connection

VistaPure AutoFill S3020

STAT CLAVE G4 Chamber Autoclaves G4-621101

VistaPure Autofill - STAT IM VistaPure Autofill - BRAVO

STAT CLAVE G4, 120V, 10A, 60 Hz STAT CLAVE G4, 208V-240V, 12A, 60Hz

G4-622301

S3030

Recommended Accessories and Spare Parts 01-115481S Door Seal 01-115479S Bacteriological Air Filter 01-115478S Chamber Filter Kit (3 Filters) 01-115487S Chamber Rack 01-115482S Wire Instrument Tray 01-115483S Pouch Rack 01-115485S

DrainHub DH154

Drain Hub 4 Hole Drain Hub 8 Hole

DH158

All recommend fittings

DH8200

VistaCool V7501

Tray Extractor with Door Unlock Pin

VistaCool - Single Autoclave System VistaCool - Double Autoclave System VistaCool 3 - Single Autoclave System

Drying plate

01-115484S 01-115374

V7502 V7601

Automatic fill pump

BRAVO Chamber Autoclave M7A310011

STAT MATIC and Spray S30000-NA

BRAVO 17V, 120V, 15A, 60Hz, No Printer

STAT MATIC Recommended Accessories, Spare Parts and Consumables STM500-6NA STAT MATIC Spray S30102 Absorption Pad (6 pack) S30101-BA Maintenance Coupling Bien Air S30101-E Maintenance Coupling E-type S30101-KVH Maintenance Coupling KaVo Intra Head S30101-MW Maintenance Coupling Midwest Slow Speed S30101-CX Maintenance Coupling MULTIflex/Connex S30101-NSK Maintenance Coupling NSK S30101-ST1T Maintenance Coupling Sirona T1 Highspeed S30101-ST1I Maintenance Coupling Sirona T1 Instrument S30101-W&H Maintenance Coupling W&H

BRAVO 17V, 220V, 10A, 60Hz, No Printer, with Datalogger

M7A310013

M7A310014 *Special Order: No Returns or Exchanges

BRAVO 17V, 220V, Datalogger and Printer

BRAVO 21V, 120V, 15A, No Printer, with Datalogger BRAVO 21V, 220V, 10A 60Hz, No Printer, with Datalogger

M7A320011 M7A320013

M7A320012 *Special Order: No Returns or Exchanges M7A320014 *Special Order: No Returns or Exchanges

BRAVO 21V, 120V 20A, 60 Hz, with Printer and Datalogger

BRAVO 21V, 220V, 10A 60Hz, with Printer and Datalogger

Recomended Accessories and Spare Parts 47200010000 Biological Filter 48000050000 Door Gasket STXX0080000 Tray Handle 47200030000 Chamber Drain Filter 01-111774S Water Intake Pull Kit 01-111775S Direct-to-Drain Kit

HYDR IM G4 Instument Washers L110W-D01-G4

HYDR IM L110W G4 Instrument Washer

C61W-D01 HYDR IM C61W G4 Instrument Washer Recommended Accessories, Spare Parts and Consumables CS-HIPL HIP Cleaning Solution for HYDR IM L110W CS-HIPC-U HIP Ultra Solution for HYDR IM C61W 01-113277S Air Filter for HYDR IM C61W WTI-SK Wash Test Indicator (Starter Kit) WTI-RK Wash Test Indicator (Refill Kit) WTI-HOLDER Wash Test Indicator (Holder)

ENSURE SCI-BISK-20 SCI-BINC-120

Ensure BI Starter Kit Ensure Incubator

Ensure BI System Log Book

SCI-BILOG SCI-BI100

Ensure BI’s (100 count refill boxes) Ensure BI’s (25 count refill boxes) Chemical Indicator Strips (250 count)

SCI-BI25

SCI134

Ensure Bowie-Dick Starter Kit Ensure Bowie-Dick Test Cards

SCI-BDSK134V

SCI-BD134V SCI-BDCH

Ensure Bowie-Dick Test Card Holder Ensure Type 5 Integrators (100/bag)

SCI-T5

Ensure Sterilization Pouches

SCI-SCP

VistaPure ™ , VistaPure ™ Autofill, VistaCool ™ and DrainHub ™ are manufactured by:

Manufactured by: SciCan Ltd. 1440 Don Mills Road, Toronto, ON M3B 3P9 Tel: 416-445-1600 Fax: 416-445-2727 Toll free: 1-800-667-7733 customerservice@scican.com

Vista Research Group 1244 County Road 1475 Ashland, OH 44805 USA Tel: (419) 281-3927 VistaResearchGroup.com

†  Distributed by: SciCan Ltd. 1440 Don Mills Rd., Toronto, ON M3B 3P9 / Canada Tel: 416 445 1600 Toll free: 1 800 667 7733 customerservice@scican.com

† Manufactured by: Virox Technologies Inc. 2770 Coventry Rd, Oakville, ON Canada, L6H 6R1 Tel: (905) 813-0110

www.scican.com

SD-551 CA EN R2. STAT IM , HYDR IM , and OPT IM are registered trademarks and SciCan SPEC, BRAVO, STAT CLAVE and STAT MATIC are trademarks of SciCan Ltd. VistaCool, VistaPure and DrainHub are trademarks of Vista Research Group.

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24

Made with FlippingBook interactive PDF creator