910121_PTS Brochure

ABC-170 / ABC-170 CE The ABC-170/170CE power processing system is used to meet fuel cell testing and sinking power needs. Originally developed for fuel cell testing applications and for systems that require additional sinking power, Webasto customers have also used this versatile machine to cycle hybrids and batteries.

The ABC-170 offers power from +125kW to - 170kW, with a voltage range of 8 to 445 VDC and a current range of +530ADC to - 640ADC.

Technical Specifications

ABC-170

ABC-170 CE

3 Phase, 240VAC

3 Phase, 400, 415 and 480 VAC

Input Voltage Options

340Amps

203, 195, and 170 Amps respectively

Currency Draw

60Hz (50 Hz available)

50Hz (60 Hz optional)

Frequency

Requires external isolation transformer with 225KVA, 240Vrms secondary

Internal transformer

Isolation transformer

> 99%

> 99%

Power factor

< 3% THD; IEEE 519 Compliant

< 3% THD; IEEE 519 Compliant

Harmonic distortion

Manual; Remote Operation System (ROS); DCOM Driver for LabVIEW; C++ and Visual Basic; CAN

Manual; Remote Operation System (ROS); DCOM Driver for LabVIEW; C++ and Visual Basic; CAN

Multiple User Interfaces

< 0.5Arms

< 0.5Arms

Current Ripple - Indepdendent & parallel mode

< 15Arms

< 15Arms

Current Ripple - Max ripple from load

0-35°C

0-35°C

Operating Environment - Temperature

5-90% non-condensing

5-90% non-condensing

Operating Environment - Humidity

1334 lbs (605 kg)

3925 lbs (1780 kg)

Weight

46” W x 55” H x 26” D (117cm W x 140cm H x 65cm D)

73”W x 71”H x 30”D (183cm W x 180cm H x 76cm D)

Dimensions

Operating Range Configuration

Voltage (Vdc)

Current (Adc)

Power (kW)

+8 to +420

-320 to +265

-170 to +125

Independent

+420 to +435

-160 to +160

-70 to +70

Optional Range

+435 to +445

-90 to +90

-40 to +40

+8 to +420

-640 to +530

-170 to +125

Parallel

+420 to +435

-160 to +160

-70 to +70

Optional Range

+435 to +445

-90 to +90

-40 to +40

Accuracy & Resolution Measurement

Accuracy (±)

Resolution

250mV or 0.15% of the output voltage

20mV

Voltage

100mA or 0.25% of the reading

20mA

Current Independent (2 channels)

200mA or 0.35% of the reading

40mA

Current External Parallel (1 channels)

17

Made with FlippingBook Online newsletter