Web Interface – Configuration
Security Level Set or show the security level that this entry should belong to. Possible security models are:
NoAuth, NoPriv:
No authentication and no privacy
¾
Auth, NoPriv:
Authentication and no privacy
¾
Auth, Priv:
Authentication and privacy
¾
Read View Name Set or show the name of the MIB view defining the MIB objects for which this request may request the current values. The allowed string length is 1 to 32, and the allowed content is ASCII characters from 33 to 126. Write View Name Set or sow the name of the MIB view defining the MIB objects for which this request may potentially set new values. The allowed string length is 1 to 32, and the allowed content is ASCII characters from 33 to 126.
4.23.2 Access Configuration Buttons Add New Entry:
Click to add a new access configuration
Save:
Click to save all changes
Reset:
Click to undo any changes made locally and revert to previously saved values
Confidential