Web Interface – Configuration
4.25 Security – Switch – RMON – History
The user can configure the History table on this page.
4.25.1 SNMPv3 Access Configuration
Configure RMON History table on this page. The entry index key is ID.
The History Statistics Configuration Page has the following parameters:
Delete
Check to delete the entry. It will be deleted during the next save.
Do not delete the entry. (This is the default.)
ID Indicates the index of the entry. The range is from 1 to 65535.
Data Source Indicates the port ID which wants to be monitored. If in stacking switch, the value must add 1000000*(switch ID-1), for example, if the port is switch 3 port 5, the value is 2000005. Interval Indicates the interval in seconds for sampling the history statistics data. The range is from 1 to 3600, default value is 1800 seconds.
Confidential
User Guide: CE Services
Page 183