CE Services Products - User Guide

Web Interface – Configuration

ARP/RARP frames where the HLN is equal to Ethernet (0x06) and the (PLN) is equal to IPv4 (0x04)

Any:

Any value is allowed ( “ don ’ t-care ” )

IP Specify whether frames can hit the action according to their ARP/RARP hardware address space (HRD) settings. 0: Not a Match ARP/RARP frames where the HLD is not equal to Ethernet (1) 1: Match ARP/RARP frames where the HLD is equal to Ethernet (1) Any: Any value is allowed ( “ don ’ t-care ” ) Ethernet Specify whether frames can hit the action according to their ARP/RARP protocol address space (PRO) settings. 0: Not a Match ARP/RARP frames where the PRO is not equal to IP (0x800) 1: Match ARP/RARP frames where the PRO is equal to IP (0x800) Any: Any value is allowed ( “ don ’ t-care ” )

4.32.2.5 IP Parameters

The IP parameters can be configured when Frame Type “ IPv4 ” is selected.

IP Protocol Filter Set or show the IP protocol filter for this ACE. Any:

No IP protocol filter is specified ( “ don ’ t care ” ) Specific: Filter a specific IP protocol filter with this ACE. A field for entering an IP protocol filter appears

Confidential

User Guide: CE Services

Page 218