Web Interface – Configuration
1: TCP frames where the PSH field is set must be able to match this entry Any: Any value is allowed ( “ don ’ t-care ” ) TCP ACK Set or show the TCP “ Acknowledgment field significant ” (ACK) value for this ACE. 0: TCP frames where the ACK field is set must not be able to match this entry 1: TCP frames where the ACK field is set must be able to match this entry Any: Any value is allowed ( “ don ’ t care ” ) TCP URG Set or show the TCP “ Urgent Pointer field significant ” (URG) value for this ACE. 0: TCP frames where the URG field is set must not be able to match this entry 1: TCP frames where the URG field is set must be able to match this entry Any: Any value is allowed ( “ don ’ t care ” )
4.32.2.9 Ethernet Type Parameters
The Ethernet Type parameters can be configured when Frame Type “ Ethernet Type ” is selected.
EtherType Filter Set or show the Ethernet type filter for this ACE. Any:
No EtherType filter is specified (EtherType filter status is “ don ’ t care ” ) Specific: To filter a specific EtherType filter with this ACE, the user can enter a specific EtherType value. A field for entering an EtherType value appears. Ethernet Type Value When “ Specific ” is selected for the EtherType filter, the user can enter a specific EtherType value. The allowed range is 0x600 to 0xFFFF but excluding 0x800(IPv4), 0x806(ARP) and 0x86DD(IPv6). A frame that hits this ACE matches this EtherType value.
4.32.2.10 ACE Configuration Buttons Save: Click to save all changes