RES-SCE-8MG - SMB CLI - User Manual Rev 1.01 - A TERMINER

Any: Any value is allowed (“don’t care”)

4.23.2.9

Ethernet Type Parameters The Ethernet Type parameters can be configured when Frame Type “Ethernet Type” is selected.

EtherType Filter Set or show the Ethernet type filter for this ACE. Any:

No EtherType filter is specified (EtherType filter status is “don’t care”) Specific: To filter a specific EtherType filter with this ACE, the user can enter a specific EtherType value. A field for entering an EtherType value appears. Ethernet Type Value When “Specific” is selected for the EtherType filter, the user can enter a specific EtherType value. The allowed range is 0x600 to 0xFFFF but excluding 0x800(IPv4), 0x806(ARP) and 0x86DD(IPv6). A frame that hits this ACE matches this EtherType value.

4.23.2.10

ACE Configuration Buttons Save:

Click to save all changes

Reset:

Click to undo any changes made locally and revert to previously saved values

Cancel: Return to the previous page

SMB - CLI UM

Rev: 1.1

Page 134 of 275

www.amphenol-socapex.com

Tel : +33(0)4.50.89.28.00

Made with FlippingBook interactive PDF creator