The default value is “Any”. VID Display the VLAN ID, either a specific VID or range of VIDs. VID can be in the range 1-4095 or “Any”.
PCP Display the Priority Code Point. Valid values of PCP are: Specific: (0, 1, 2, 3, 4, 5, 6, 7) Range: (0-1, 2-3, 4-5, 6-7, 0-3, 4-7) “Any”
DEI Display the Drop Eligible Indicator. Valid values of DEI are 0, 1 or “Any”. Frame Type Display the type of frame. Possible values are: Any: Match any frame type Ethernet: Match EtherType frames LLC: Match (LLC) frames SNAP: Match (SNAP) frames IPv4: Match IPv4 frames IPv6: Match IPv6 frames Action Display the classification action taken on ingress frame if parameters configured are matched with the frame’s content. Possible actions are: CoS: Classify Class of Service DPL: Classify Drop Precedence Level DSCP: Classify DSCP value PCP: Classify PCP value DEI: Classify DEI value Policy: Classify ACL Policy number Modification Buttons You can modify each QCE (QoS Control Entry) in the table using the following buttons:
: Inserts a new QCE before the current row
: Edits the QCE
: Moves the QCE up the list
: Moves the QCE down the list
: Deletes the QCE