RES-SCE-8MG - SMB CLI - User Manual Rev 1.01 - A TERMINER

2.3.13.3

green-ethernet led on-event Specifies when to turn LEDs on at 100% intensity. Syntax: green-ethernet led on-event { [ link-change <v_0_to_65535> ] [ error ] }*1 link-change: specifies how long to turn LEDs intensity to 100%, when a link changes state <v_0_to_65535>: number of seconds to set LEDs intensity to 100% at link change, values 0 to 65,535 [ error ]: set LEDs intensity to 100% if an error occurs

2.3.14

Help Description of the interactive help system Syntax: help

2.3.15

Hostname Set system's network name. Syntax: hostname <hostname>

2.3.16

Interface – Port Type Select an interface to configure. Syntax: interface ( <port_type> [ <plist> ] ) interface: <port_type>, values are: *

All switches or all ports GigabitEthernet: set specific Gigabit Ethernet Port number <plist> port list in 1/1-8

Input:

AMP8MG(config)# interface *

Or Input: AMP8MG(config)# interface gigabitethernet 1/8 Output (prompt change to interface mode – port type): AMP8MG(config-if)#

2.3.16.1

(Interface – Port Type) Access-List The following access-list options are available: Access-List Action Set the access-list action. Syntax: access-list action <deny | permit>

SMB - CLI UM

Rev: 1.1

Page 25 of 275