Oman Low-Voltage-Power-and-Control-Cables

Sl No Description

Table No Page No.

4mm 2 CU/PVC/PVC

40

33 34

12 Current Ratings of Cables:

Current Ratings & Voltage Drop Of The Cables - 600/1000 V Single Core Copper, XLPE insulated Armoured/Unarmoured Cables. Two Core Copper, XLPE insulated Armoured/Unarmoured Cables. 3 and 4 Core, Copper, XLPE insulated Armoured/Unarmoured Cables. Single Core Aluminium, XLPE insulated Armoured/Unarmoured Cables. Two Core Aluminium, XLPE insulated Armoured/Unarmoured Cables. 3 and 4 Core, Aluminium, XLPE insulated Armoured/Unarmoured Cables. Single Core Copper, PVC insulated Armoured/Unarmoured Cables. Two Core Copper, PVC insulated Armoured/Unarmoured Cables. 3 and 4 Core, Copper, PVC insulated Armoured/Unarmoured Cables. Single Core Aluminium, PVC insulated Armoured/Unarmoured Cables. 2 Core Aluminium, Copper, PVC insulated Armoured/Unarmoured Cables. 3 and 4 Core, Aluminium, PVC insulated Armoured/Unarmoured Cables. Rating Factors For Variation In Ambient Temperature For Cables Laid In Air

41 42 43 44 45 46 47 48 49 50 51 52 53

34 35 36 37 38 39 40 41 42 43 44 45 46

Rating Factors For Variation In Ambient Temperature For Cables Laid Direct In Ground Or In Ducts Rating Factors For Depth Of Laying For Cables Laid Direct In Ground Or In Ducts

54

46

55

46

Rating Factors For Variation In Thermal Resistivity Of Soil For Two Or Three Single-Core Cables Laid Direct In The Ground Rating Factors For Variation In Thermal Resistivity Of Soil For Twin Or Multi Core Cables Laid Direct In The Ground Rating Factors For Variation In Thermal Resistivity Of Soil For Three Single-Core Cables In Ducts Rating Factors For Variation In Thermal Resistivity Of Soil For Twin Or Multi-Core Cables Laid In Single-Way Ducts Group Rating Factors For More Than One Twin Or Multi-Core Armoured Or Unarmoured Cables In Horizontal Formation Laid In Direct Ground. Group Rating Factors For More Than One Circuits Of 3 Single Core Armoured Or Unarmoured Cables In Trefoil Touching,Horizontal Formation Laid In Direct Ground Group Rating Factors For More Than One Twin Or Multi-Core Armoured Or Unarmoured Cables In Horizontal Formation Laid In Single Way Ducts Group Rating Factors For More Than One Circuits Of 3 Single Core Armoured Or Unarmoured Cables In Trefoil Touching ,Horizontal Formation Laid In Single Way Ducts Group Rating Factors For Groups Of More Than One Multi-Core Cable In Air to Be Applied To The Current-Carrying Capacity For One Multi-Core Cable In Free Air Group Rating Factors For Groups Of More Than One Circuit Of Single Core Cables To Be Applied To The Current-Carrying Capacity For One Circuit Of Single-Core Cables In Free Air Maximum D.C. Resistance Of Conductor And Armour For XLPE Insulated Cables Maximum D.C. Resistance Of Conductor And Armour For PVC Insulated Cables A.C. Resistance And Reactance Values For XLPE Insulated Cables A.C. Resistance And Reactance Values For PVC Insulated Cables

56

47

57

47

58

48

59

48

60

49

61

49

62

49

63

49

64

50

65

51

66

52

67

53

68 69

54 55

Short Circuit Current Curves For Copper Conductor XLPE Insulated Cables Short Circuit Current Curves For Copper Conductor PVC Insulated Cables Short Circuit Current Curves For Aluminium Conductor XLPE Insulated Cables Short Circuit Current Curves For Aluminium Conductor PVC Insulated Cables

13

56

14

57

15

58

16

59