sd-549_569-ca-en-r2-hydrimc61g4-ss_wti-ss_web

C61W G4 Instrument Washer HYDR IM ® G4

WIFI ENABLED

Automated Instrument Washing the first step in the sterilization process

Efficient The time saved by automated washing compared to manual cleaning is approximately 1 hour of labour for every nine procedural set-ups 1 . HYDR IM C61W G4 cycle times are as fast as 40 minutes from start to dry. HYDR IM ensures that every set of instruments receives the same validated cleaning process. G4 Technology There is nothing like SciCan’s G4 Technology. The large touch screen gives in-depth cycle information and allows users to view current operations. From the networking portal, users can access cycle history and validation information. If there is ever a cycle fault, the G4 software will send an email to the office and the service technician, allowing remote troubleshooting.

Safe Avoid the many steps involved with manual washing or using ultrasonic cleaners. Steps such as pre-soaking, scrubbing and drying instruments before sterilization increase the exposure to blood and body fluids and the risk of sharps injuries. Automated instrument washing reduces physical handling of contaminated instruments. Using the HYDR IM G4 instrument washer is the safer and more effective option, decreasing the risk of exposure and injuries. HYDR IM G4 saves time and money—making it a worthy investment for today’s standard of care. Capacity HYDR IM C61W G4 has a 6 full-size cassette capacity, allowing offices to turnover 120 instruments in as little as 40 minutes, start to dry.

1 Tholen, Mark. “Increase production and decrease expenses in sterilization.” Dental Economics, Volume 99, Issue 10, October 1, 2009.

Recommended Accessories Part Number Description 01-113251 6-Cassette Rack 01-113252 4 Cassette Rack 01-113253 3-Cassette, 2-Basket Rack 01-113254 10-Tray, 2-Basket Rack 01-113257 Trolley Center Support 01-113545 Large Basket 01-113546 Hygiene Basket 01-113547 Basket with Hinged Lid CS-HIPC-U HIP ULTRA Cleaning Solution

HYDR IM C61W G4 Specifications

Unit Size

Dimensions (W x H x D):

598 x 520 x 526mm / 23.5” x 20.5” x 20.7”

Depth with Door Open:

829 mm / 32.6”

Weight:

44 kg / 97 lb

Cycle Times*

Rinse and Hold

5 min

Regular Wash + Dry

26 min + 10 min

Heavy Duty Wash + Dry

30 min + 10 min

Water Consumption Per Cycle

Rinse and Hold

7.6 L / 1.7 Gal

Regular Wash

11.5 L / 3 Gal

Heavy Duty Wash

11.5 L / 3 Gal

Electrical Connection

North America

208-240 V, 12 A, 60 Hz

Running Noise

65 dB

Water and Drain Connections Hot and Cold Water Tap Connection

3/4” Garden Hose, Male

Recommended Hot Water Temperature

60º C / 140º F

Cold Water Temperature

< 30º C / 86º F

Inlet Water Pressure

1-10 bar / 14.5-145 psi

Drain

2 cm / 3/4”

*Actual cycle times will vary with incoming water temperature and pressure.

VistaPure ™ Water Filtration

HYDR IM VistaPure Connection

Provides two grades of high- quality water for autoclaves, dental bottles, ultrasonic cleaners and the rinse cycle of instrument washers. V3000

Protect expensive instruments and equipment by using the VistaPure system’s hyperfiltered water for the final-rinse cycle of the HYDR IM for a spot-free finish. V3010

VistaPure Water Filtration shown above.

VistaPure is manufactured by: Vista Research Group 1244 County Road 1475. Ashland, OH 44805 USA Tel: (419) 281-3927 VistaResearchGroup.com

Manufactured by: SciCan Ltd. 1440 Don Mills Rd., Toronto, ON, Canada, M3B 3P9 Tel: 416-445-1600 Toll free: 1-800-667-7733 customerservice@scican.com

www.scican.com

SD-549 CA EN R2 HYDR IM is a registered trademark of SciCan Ltd. VistaCool and VistaPure are trademarks of Vista Research Group.

Monitoring Instrument Washers HYDR IM ® WASH TEST INDICATORS

THINK OF IT AS A ROUTINE CHECK UP for your washer

The HYDR IM Wash Test Indicators (WTIs) have been designed to provide two-dimensional validation of HYDR IM washing efficacy. It is a simple, easy-to-use indicator that ensures instruments are effectively and consistently cleaned with HIP Cleaning Solution.

Safe Synthetic test soil (non-toxic indicator) designed to monitor the efficacy of HYDR IM washers. Easy WTI wash off characteristics clearly indicate whether the wash cycle has passed or failed; clean indicator at the end of the cycle indicates an effective cleaning process.

Smart Design Indicators are folded “back-to-back” and placed inside the holder, monitoring spray performance from two directions. Reliable Designed to provide verification of a consistently effective cleaning process in HYDR IM washers.

THE ONLY VALIDATED AND EFFECTIVE CLEANER IN THE MARKET for use in HYDRIM units.

HIP Cleaning Solution

HIP Cleaning Solution is designed to remove any type of protein/debris from instruments. HIP is automatically added at various stages in the cycle to optimize the cleaning and protection of instruments. To maximize HYDR IM cleaning process, it is essential to use the certified and validated HIP Cleaning Solution that works for your HYDR IM unit during the wash cycle.

HIP Cleaning Solution for HYDR IM L110W

HIP Ultra Cleaning Solution for HYDR IM C61W

Designed for HYDR IM L110W, HIP Cleaning Solution box fits inside L110W, instead of taking up cabinet space. Strong, built-in tube connector prevent leaks.

Designed for HYDR IM C61W, HIP Ultra Cleaning solution pouches fit inside the C61W, instead of taking up cabinet space. Strong, built-in tube connector prevent leaks.

Part Numbers Part Number

Description

Starter Kit (One Holder and 32 Indicators)

WTI-SK

WTI-RK CS-HIPL

Refill Kit (96 Indicators) HIP Cleaning Solution HIP Ultra Solution HYDR IM C61W G4 HYDR IM L110W G4

Distributed by: SciCan Inc. 701 Technology Dr., Canonsburg, PA 15317, USA Tel: 724-820-1600 Toll Free: 1-800-572-1211 uscustomerservice@scican.com

Manufactured for: SciCan Ltd. 1440 Don Mills Rd., Toronto, ON, Canada, M3B 3P9 Tel: 416-445-1600 Toll free: 1-800-667-7733 customerservice@scican.com

CS-HIPC-U C61W-D01

L110W-D01-G4

www.scican.com