L110W G4 Instrument Washer HYDR IM ® G4
WIFI ENABLED
Automated Instrument Washing the first step in the sterilization process
Efficient The time saved by automated washing compared to manual cleaning is approximately 1 hour of labour for every nine procedural set-ups 1 . HYDR IM L110W G4 cycle times are as fast as 44 minutes from start to dry. HYDR IM ensures that every set of instruments receives the same validated cleaning process. G4 Technology There is nothing like SciCan’s G4 Technology. The large touch screen gives in-depth cycle information and allows users to view current operations. From the networking portal, users can access cycle history and validation information. If there is ever a cycle fault, the G4 software will send an email to the office and the service technician, allowing remote troubleshooting.
Safe Avoid the many steps involved with manual washing or using ultrasonic cleaners. Steps such as pre-soaking, scrubbing and drying instruments before sterilization increase the exposure to blood and body fluids and the risk of sharps injuries. Automated instrument washing reduces physical handling of contaminated instruments. Using the HYDR IM G4 instrument washer is the safer and more effective option, decreasing the risk of exposure and injuries. HYDR IM G4 saves time and money—making it a worthy investment for today’s standard of care. Capacity HYDR IM L110W G4 has a 10 full-size cassette capacity allowing offices to turn over 2500 instruments in a 10 hour day.
1 Tholen, Mark. “Increase production and decrease expenses in sterilization.” Dental Economics, Volume 99, Issue 10, October 1, 2009.
Recommended Accessories Part Number Description 01-109963S 5-Cassette Rack, Full Size 01-109964S 5-Cassette Rack, Half Size 01-109965S 4 XL Cassette Rack, Full Size 01-109967S Hygiene Basket 01-107240 STATIM 2000 Basket 01-107241 STATIM 5000 Basket 01-108232 Long Basket CS-HIPL HIP Cleaning Solution L110w
HYDR IM L110W G4 Specifications
Unit Size
Dimensions (W x H x D):
598 x 850 x 600 mm /23.54” x 33.5” x 23.75”
Depth with Door Open:
1200 mm / 47”
Weight:
80 kg / 176 lb
Cycle Times*
Rinse and Hold
17 min
Regular Wash + Dry
25 min + 10 min
Heavy Duty Wash + Dry
34 min + 10 min
Water Consumption Per Cycle
Rinse and Hold
16 L / 4.23 Gal
Regular Wash
24 L / 6.34 Gal
Heavy Duty Wash
32 L / 8.45 Gal
Electrical Connection
North America
208-240 V, 15 A, 60 Hz
Running Noise
< 78 dB (Wash)
Water and Drain Connections Hot and Cold Water Tap Connection
3/4” Garden Hose, Male
Recommended Hot Water Temperature
60º C / 140º F
Cold Water Temperature
< 30º C / 86º F
Inlet Water Pressure
1-10 bar / 14.5-145 psi
Drain
2 cm / 3/4”
*Actual cycle times will vary with incoming water temperature and pressure.
VistaPure ™ Water Filtration
HYDR IM VistaPure Connection
Provides two grades of high- quality water for autoclaves, dental bottles, ultrasonic cleaners and the rinse cycle of instrument washers. V3000
Protect expensive instruments and equipment by using the VistaPure system’s hyperfiltered water for the final-rinse cycle of the HYDR IM for a spot-free finish. V3010
VistaPure Water Filtration shown above.
Manufactured by: SciCan Ltd. 1440 Don Mills Rd., Toronto, ON, Canada, M3B 3P9 Tel: 416-445-1600 Toll free: 1-800-667-7733 customerservice@scican.com
VistaPure is manufactured by: Vista Research Group 1244 County Road 1475, Ashland, OH 44805 USA Tel: (419) 281-3927 VistaResearchGroup.com
www.scican.com
SD-550 CA EN R2 HYDR IM is a registered trademark of SciCan Ltd. VistaCool and VistaPure are trademarks of Vista Research Group.
Monitoring Instrument Washers HYDR IM ® WASH TEST INDICATORS
THINK OF IT AS A ROUTINE CHECK UP for your washer
The HYDR IM Wash Test Indicators (WTIs) have been designed to provide two-dimensional validation of HYDR IM washing efficacy. It is a simple, easy-to-use indicator that ensures instruments are effectively and consistently cleaned with HIP Cleaning Solution.
Safe Synthetic test soil (non-toxic indicator) designed to monitor the efficacy of HYDR IM washers. Easy WTI wash off characteristics clearly indicate whether the wash cycle has passed or failed; clean indicator at the end of the cycle indicates an effective cleaning process.
Smart Design Indicators are folded “back-to-back” and placed inside the holder, monitoring spray performance from two directions. Reliable Designed to provide verification of a consistently effective cleaning process in HYDR IM washers.
THE ONLY VALIDATED AND EFFECTIVE CLEANER IN THE MARKET for use in HYDRIM units.
HIP Cleaning Solution
HIP Cleaning Solution is designed to remove any type of protein/debris from instruments. HIP is automatically added at various stages in the cycle to optimize the cleaning and protection of instruments. To maximize HYDR IM cleaning process, it is essential to use the certified and validated HIP Cleaning Solution that works for your HYDR IM unit during the wash cycle.
HIP Cleaning Solution for HYDR IM L110W
HIP Ultra Cleaning Solution for HYDR IM C61W
Designed for HYDR IM L110W, HIP Cleaning Solution box fits inside L110W, instead of taking up cabinet space. Strong, built-in tube connector prevent leaks.
Designed for HYDR IM C61W, HIP Ultra Cleaning solution pouches fit inside the C61W, instead of taking up cabinet space. Strong, built-in tube connector prevent leaks.
Part Numbers Part Number
Description
Starter Kit (One Holder and 32 Indicators)
WTI-SK
WTI-RK CS-HIPL
Refill Kit (96 Indicators) HIP Cleaning Solution HIP Ultra Solution HYDR IM C61W G4 HYDR IM L110W G4
Distributed by: SciCan Inc. 701 Technology Dr., Canonsburg, PA 15317, USA Tel: 724-820-1600 Toll Free: 1-800-572-1211 uscustomerservice@scican.com
Manufactured for: SciCan Ltd. 1440 Don Mills Rd., Toronto, ON, Canada, M3B 3P9 Tel: 416-445-1600 Toll free: 1-800-667-7733 customerservice@scican.com
CS-HIPC-U C61W-D01
L110W-D01-G4
www.scican.com
Page 1 Page 2 Page 3 Page 4Made with FlippingBook interactive PDF creator