® Submersible Contractor Pumps Pump Dimensional & Specification Data
A Gorman-Rupp Company
ShipWt. (Lbs.)
Voltage @60Hz
Full Load Amps
ShipWt. (Lbs.)
Voltage @60Hz
Full Load Amps
§
Port NPT
Model
A
H
W
Port NPT Curve
HP PH
§
Model
A
H
W
Curve
HP PH
115 Voltage @ 60 Hz 1
13 Full Load Amps
53 Ship Wt. (Lbs.)
5770-95
115
2
2.8 [7.1]
19.3 [49.0]
8.3 [21.1]
A
1
5770-95
13
2
2.8 [7.1]
19.3 [49.0]
8.3 [21.1]
A
1
1
53
Model
Curve Port NPT Port NPT HP PH
A §
W
H
5771-95
7
230
2
2.8 [7.1]
19.3 [49.0]
8.3 [21.1]
A
1
1
51
5770-95 5771-95 5773-95 5777-95 577A-95 577B-95 577D-95 577E-95
115
13
53 51
5771-95
7
230
2
2.8 [7.1]
19.3 [49.0]
8.3 [21.1]
A
1
1
51
A
1
2.8 [7.1]
8.3 [21.1]
19.3 {49.0]
5773-95
11
230
2
3.2 [8.1]
25.6 [65.0]
9.0 [22.8]
B
2
1
103
2
7
5773-95
11
230
2
3.2 [8.1]
25.6 [65.0]
9.0 [22.8]
B
2
1
103
1
B C
2 3
11 18 14
25.6 [65.0] 26.4 [67.0]
103 110 110 115 172 175
5777-95
18
230
3
3.2 [8.1]
26.4 [67.0]
9.0 [22.8]
C
3
1
110
230
3.2 [8.1]
9.0 [22.8]
5777-95
18
230
3
3.2 [8.1]
26.4 [67.0]
9.0 [22.8]
C
3
1
110
577A-95
14
230
3
4.0 [10.1]
23.9 [60.7]
9.2 [23.3]
D
5
3
110
577A-95
14
230
3
4.0 [10.1]
23.9 [60.7]
9.2 [23.3]
D
5
3
110
3
D
5
4.0 [10.1]
9.2 [23.3]
23.9 [60.7]
577B-95
7
460
3
4.0 [10.1]
23.9 [60.7]
9.2 [23.3]
D
5
3
115
460 230 460
7
577B-95
7
460
3
4.0 [10.1]
23.9 [60.7]
9.2 [23.3]
D
5
3
115
3
20 11
577D-95
20
230
4
5.0 [12.7]
28.4 [72.1]
10.7 [27.2]
E
7-1/2 3
172
577D-95
20
230
4
5.0 [12.7]
28.4 [72.1]
10.7 [27.2]
E
7-1/2 3 7½
172
E
4
5.0 [12.7]
10.7 [27.2]
28.4 [72.1]
577E-95
11
460
4
5.0 [12.7]
28.4 [72.1]
10.7 [27.2]
E
7-1/2 3
175
577E-95
11
460
4
5.0 [12.7]
28.4 [72.1]
10.7 [27.2]
E
7-1/2 3
175
(*) Standard NPT (Female) Pipe Thread NOTE: Dimensions are in inches (centimeters) and have a tolerance of ± 1/8" NOTE: Electric Supply for ALL motors must be within ± 10% of nameplate voltage (Ex: 230V = 203 to 253) (§) Minimum Liquid Height (*) Standard NPT (Female) Pipe Thread NOTE: Dimensions are in inches (centimeters) and have a tolerance of ± 1/8" NOTE: Electric Supply for ALL motors must be within ± 10% of nameplate voltage (Ex: 230V = 203 to 253) (§) Minimum Liquid Height
(*) Standard NPT (Female) pipe thread. NOTE: Dimensions are in inches (centimeters) and have a tolerance of ± 1/8”. NOTE: Electric supply for ALL motors must be within ± 10% of nameplate voltage rating (e.g 230V ± 10%=207 to 253). ( § ) Minimum Liquid Height
H
H
W
W
A §
A §
§ Minimum Liquid Height
Standard Features
§ Minimum Liquid Height
• Cast Iron Construction • Hi Chromium (HCr) Impeller and Cover • Stainless Steel Motor Housing • Silicon Carbide Seal with Shaft Seal • UL/CSA Listed • 32 Ft. Cord with No Plug- (Model 5770-95 Includes 20 Ft. cord with plug.)
• Suction Screen • Carrying Handle • Maximum Temperature 104° F • Maximum Solids up to 3/8" Diameter • QSP – Quick Ship Pumps
Manufacturer of AMT & IPT Pumps 400 Spring Street • Royersford, PA 19468 USA
®
www.amtpump.com • 888-amt-pump (268-7867) The Gorman-Rupp Company reserves the right to discontinue any model or change specifications at any time without incurring any obligation. ©2012 American Machine and Tool Company. All rights reserved.
A Gorman-Rupp Company
1212 1219
SUB-12