2023 Master Catalog

temperature & humidity

Moisture Analyzers IR/Precision Thermometers

Extech Wide Range IR Thermometers

Non-contact IR thermometers measure up to 1832°F.

• Range: -58° to 1200°F (42510A), -58° to 1832°F (42545) • Laser Pointer Identifies Target Area • °F / °C Switchable

• Backlit Display • Automatic Data Hold • Three Year Warranty • Includes 9V Battery and Case

Specifications

Mfg #

42510A

42545

IR267

IR400

42570

-58° to 1200°F (-50° to 650°C)

-58° to 1832°F (-50° to 1000°C) 0.1°F / °C up to 200° ±2% of Reading up to 1000°F (538°C) ±3% of Reading >1000°F (538°C)

-58 to 1112°F (-50 to 600°C)

-4 to 630°F (-20 to 332°C)

-58 to 3992°F (-50 to 2200°C)

Range

C

0.1°F / °C up to 200°

Resolution

0.1°F / °C

0.1°F/°C

0.1°F/°C

42545

±3°F / 2.5°C 28° to 200°F (-2° to 94°C) ±1% to 2% of Reading >200°F (94°C)

±2% of Reading or ±4°F / 2°C

±2% of Reading or +4°F / 2°C

±(1% of Reading + 2°F / 1°C)

Basic Accuracy

Ordering Information

Mfg # Description

Order # Price

Emissivity Distance to Target Ratio

0.1 to 1.0 Adjustable 0.1 to 1.0 Adjustable 0.05 to 1.00 Adjustable

0.95 Fixed 0.1 to 1.00 Adjustable

$ 115 $ 346

42510A IR Thermometer, 1200°F 42545 IR Thermometer, 1832°F

42510A

12:1

50:1

12:1

8:1

50:1

42545

Hi / Low Alarm Min / Max / Avg/Difference

Yes

Yes

Yes

Yes

Thermometer IR Mini W/Type K, 1112°F

$ 92

IR267

IR267

Min. / Max. Only

Yes

Yes

Min. / Max. Only

Yes

$ 81

IR400 IR Thermometer, 630°F

IR400

3.2 x 1.6 x 6.3in (82 x 44 x 170mm)

3.9 x 2.2 x 9in (100 x 56 x 230mm)

6.0x4.7x1.7in (153 x 120 x 42mm) 5.1oz (145g) without Battery

3.2 x 1.6 x 6.3in (82x41.5x160mm)

8x6.1x2in (204x155x52mm)

Dimensions

IR Thermometer, Wide Range, 3992°F

$ 543

42570

42570

Weight

6.3oz (180g)

11.3oz (320g)

6.4oz (180g)

10.2oz (290g)

★ Recommended Transcat Calibration

PT1101-3 $ 262

High accuracy, Intrinsically Safe electronic thermometer designed to serve as a replacement for mercury-in-glass thermometers. Fluke Calibration Precision Thermometers

• Large LCD Display with Backlight • 300 Hour Battery Life • NVLAP Accredited Calibration (NIST Traceable) • Intrinsically Safe (ATEX Compliant)

• Range from -112° to 572°F • ± 0.05° C Accuracy Over Full Range (± 0.09°F) • Temperature Trend Indicator • User Selectable Resolution (0.1, 0.01, 0.001)

IS

Specifications

Mfg #

1551A

1552A

–50° to 160° C (–58° to 320° F)

–80° to 300° C (–112° to 572° F)

1552A

Temperature Range

Accuracy (Full Range) Probe Characterization Measurement Interval (Seconds) User Selectable Damping Computer Communications

± 0.05° C (± 0.09 ° F)

CVD

ITS-90

0.5, 1, 2

Each Unit Includes: NVLAP Accredited Report of Calibration, User’s Guide on CD-ROM, Three AAA Batteries.

ON/OFF, 2, 5, 10 RS-232 stereo jack

Ordering Information

3 AAA Batteries, Typical Battery Life of 200 Hours without LCD Backlight

DC Power

Mfg #

Description

Order #

Price

Electronics Head Dimensions (L X W X D)

1551A-9 Thermometer, Fixed RTD, -50° to 160°C, 3/16 x 9 1551A-9 $ 908 1551A-12 Thermometer, Fixed RTD, -50° to 160°C, 1/4 x 12 1551A-12 $ 873 1552A-12 Thermometer, Fixed RTD, -80° to 300°C, 1/4 x 12 1552A-12 $ 1,101 ★ Recommended Transcat Calibration RT0403-6 $ 354 Recommended Accessories 1551-CASE Case, 1551-2, Carrying 1551-CASE $ 126

4.5 x 2.25 x 1.0 inches (114 x 57 x 25 mm)

9 x 3/16 in. (229 x 5 mm) 12 x 1/4 in. (305 x 6.35 mm)

Probe Sheath Dimensions

12 x 1/4 in. (305 x 6.35 mm)

Weight

8 oz (0.23 kg)

Operating Range for All Specifications

13° to 40° C (55° to 104° F)

Operating Range

–10° to 50° C (14° to 122° F)

C29

phone : 800-828-1470 fax : 800-395-0543 TRANSCAT.com • TRANSCAT.ca

Made with FlippingBook Ebook Creator