Current Probes
electrical test
AEMC ® Instruments Current Probe Selection Chart Used with DMMs, Oscilloscopes, Data Loggers, Hand-Held Scopes, and Power Meters, these current probes feature ranges from 1mA to 2400 ARMS.
Five Questions for Selecting the Proper Current Measurement Probe 1. Do You Want to Measure AC, DC, or Both? 2. What Current Rating is Needed? 3. What is the Conductor Size? 4. Is the Required Output mV or mA? 5. What Test Lead Termination Do You Require?
For All Models Visit: Transcat.com/aemcprobes
*Picture Shows Certain Models Only
General Purpose Probes
Measurement Range
Output Signal
Max. Conductor Size 0 Cable Bus Bar
Output Connection
Mfg # Ratio
Order #
Price
AC
DC
Current
Voltage
$
91
Lead
2129.17
MN01
— 2A to 150A
— 1mAAC/AAC*
—
E
50mA to 100A 50mA to 90A 5mAac to10AAC 1 to 100AAC
$
162
— 1mA/A
—
Lead
2129.20
MN02 1000:1
0.39" (10mm)
1mV/A/mAac 1mVac/Aac 1mVAC/mAAC 1mVAC/AAC
$
120
Lead
2129.19
—
—
MN05
—
N/A
1 mA to 10A 1 A to 100A
$
235
Lead
MN103
—
MN103
—
0.47" (12mm)
$
225
MN114
— 1 mA to 10A
— 100mV Aac/AAC
Lead
MN114
—
50 mA to 120AAC
$
156
1mAAC/AAC
—
Jack
MN185
MN185 1,000:1
0.1A to 24A 0.1A to 240A
100mVAC/Aac 10mVAC/Aac 100mVDC/AC
$
199
Lead
MN255
MN255*
—
$ $
199 224
MN291* MN307*
— 0.5A to 240A — 10mA to 12A
Lead Lead
MN291 MN307
100mV/Aac
0.01A to 2.4A 0.1A to 200A
1000mV/mAac 10mV/Aac
$
230
Lead
MN373
MN373*
—
200mV/Aac 10mV/Aac
$
245
Lead
MN379
MN379
— 5 to 100A
1mV/mAAC/DC 10mV/AAC/DC
0.46" (11.8mm)
10 mA to 1.5A 50 mA to 60A
10 mA to 2A 50 mA to 80A
$
444
N/A
Lead
SL206
—
SL206*
—
1.18" (30mm) 2x500kcmil
2.48 x 0.20" (63 x 5mm)
$
215
Lead
MD301
MD301 1000:1 2A to 500A
—
— 1mVDC/Aac
$ $
184
Jack
SR600
SR600* 1,000:1 0.1A to 1,000A
1 mAac/Aac
225
SR604* 1,000:1 0.1A to 1,000A
1 mAac/Aac*
Lead
SR604
20 mAac/Aac* 10 mAac/Aac* 5 mAac/Aac*
1A to 250A 1A to 500A 1A to 1,000A
250:5 500:5 1,000:5
$
309
Jack
SR634
SR634*
$ $
215 309
SR651*
— 0.1A to 1,000A
— 1 mVAC/AAC
Jack Lead
SR651 SR704
2.05" (52mm)
1.96 x 0.19" (50 x 5mm)
—
SR704* 1,000:1 1 mA to 1,000A
1 mAac/Aac*
100mA to 1,000A
$
329
1 mVAC/AAC
Lead
SR752
SR752*
—
*Diode Protection for Open Secondary (Output)
1000 mVAC/AAC 100 mVAC/AAC 10 mV AC/AAC 1mVAC/AAC
1 mA to 1A 10mA to 10A 0.1A to 100A 1A to 1,000A
—
$
384
Lead
SR759
SR759*
—
$ $ $
575 540 550
Lead Jack Lead
JM810A JM813 JM830A
JM810A 2,000:2 1 to 2000A JM813 3,000:3 1A to 2,400A JM830A 3,000:1 1A to 2,400A
1 mAac/Aac 1 mAac/Aac
2.52" (64mm)
1.97 x 5.31" (50 x 135mm)
.333 mAac/Aac 5 mAac/Aac 2.5 mAac/Aac 1.67 mAac/Aac
—
—
1 A to 1,000A 1A to 2,000A 1A to 2,400A
1,000:5 2,000:5 3,000:5
$
640
Jack
JM865A
JM865A
ED0402-3 $
104
★ Recommended Transcat Calibration *Diode Protection for Open Secondary (Output)