Oscilloscopes Current Probes
electronic test
These scope probes are an easy and accurate way to add current measurement capability to your scope. AEMC ® Instruments Oscilloscope Current Probes
• Low Phase Shift • Overrange LED for
• Switch-Selectable Ranges • Direct BNC Connection to Scope • AmpFlex Measures from 0.5 ARMS to 300 ARMS (See Probe Spec) • Accuracy 1% of Reading ± 0.3A • TRMS Measurements when Connected to a TRMS Instrument • No Core Saturation or Damage if Overloaded
Measurement Circuitry • 1 Mhz Frequency Response • Ampflex Insensitive to DC, Measures Only AC Component on DC + AC Signals (See Probe Spec) • Sensor is Resistant to Oils and Aliphatic Hydrocarbons
SR661
SL261
JM861
High Frequency Oscilloscope Compatible MiniFlex ® Probe
Each Unit Includes: 9V Alkaline Battery and Instructions.
MF 300-14-1-1 MF 300-10-2-10-HF
Specifications
Mfg #
SL261
SR661
JM861
2 Ranges 3 Ranges Current Range Peak 100 mA to 100A AC/DC 0 1A to 1,200A AC, RMS 1A to 3,000A AC, RMS Frequency Range DC to 100 kHz 1 Hz to 1,000 kHz 10 to 50 kHz Max. Conductor Size 0 46" 2 05" 252" Accuracy ±2% to 4% Depending on Range Mfg # MN261 MF 300-10-2-10-HF Measurement Range 0 1 to 24A AC, 0 5 to 240A AC 30/300A AC Output Signal 100mV AC/A AC, 10mV AC/AA C 100mV/10mV/A Output Connection Lead w/BNC Sensor w/BNC Max. Conductor Size 078in 295in 3 Ranges
Ordering Information
Mfg #
Description
Order # Price
F
$ $ $ $ $
494 325 680 625 585 104
1201 51 Oscilloscope Current Probe SL261 2113 49 Oscilloscope Current Probe SR661
120151
SR661 JM861
JM861
Oscilloscope Current Probe JM861
2126 86 MiniFlex ® Probe MF 300-14-1-1 2126 84 MiniFlex ® Probe MF 300-10-2-10-HF ★ Recommended Transcat Calibration
212686 212684
ED0402-3 $
Fluke Oscilloscope Current Probes
Flexible and lightweight current probes.
i200s AC Current Clamp
i400s AC Current Clamp
i1000s AC Current Clamp
i2000s AC Current Clamp
i3000s AC Current Clamp
Specifications and Ordering Information
Mfg #
i200s
i400S
i1000s
i2000s Flex
i3000s
Nominal Current Ranges
0–20A/0–200A
05–400A
0 2–10/100/1,000A
0–2,000A 1,000 kA
1–30A/1–300A/1–3,000A
Highest AC Current
240A
1,000A
2,000A Peak
4,000A for 5 min
0 1 - 10A: 3% Rdg ± 10mV 0 1 - 100A: 2% Rdg ± 5mV 0 1 - 1,000A: 1% Rdg ± 1mV
1–30A: 2% of Reading + 0 1A 1–300A: 2% of Reading + 0 5A 1–3,000A: 2% of Reading + 2A
0 5A to 40A 2% + 0 015A 5A to 400A 2% + 0 04A
Accuracy (48–65 Hz)
±1%
≤ 3 5% + 0 5A
Useable Frequency Response Working Voltage
40 Hz–10 kHz
5 Hz to 10 kHz
5 Hz to 100 kHz
1 Hz–20 kHz
10 Hz to 100 kHz
600V
1,000 VAC 1,000 VAC
600 VAC 600 VAC
600 VAC
600 VAC 600 VAC
Common Mode Voltage Maximum Conductor Diameter
20mm ( 79in)
32mm (1 25in)
54mm (2 1in)
64mm x 100mm (2 5in x 3 9in)
Output Levels
10 mV, 100 mV/A
1 mV/A I400S $ 331
1 mV/A, 10 mV/A, 100 mV/A
10 mV/A, 1 mV/A
10 mV/A, 1 mV/A 0 1 mV/A
Order #
I-200S $ 300
I1000S $ 690
I2000 FLEX
I-3000S
Price
$ 510
$ 720 $ 104
★ Recommended Transcat Calibration ED0402-3
F11