Oscilloscopes Electronic Loads/Modules
electronic test
Keysight N3300 Series DC Electronic Loads
Electronic loads that will increase your manufacturing test throughput to maximize your production volume without increasing floor space.
• Increase Test System Throughput • Lower Cost of Ownership • D ecrease System Development Time • Increase System Reliability
• Increase System Flexibility • Stable Operation Down to Zero Volts • DC Connection Terminal for ATE Applications
Ordering Information
Mfg #
Description
Order # Price
$ 3,683 $ 3,140
N3300A N3301A
DC Electronic Load Mainframe, 1800W Max,6 Slots DC Electronic Load Mainframe 600W Max,2 Slots
N3300A N3301A
N3300A
Recommended Accessories
(N3300A) Rackmount Flange Kit 88.1 mm H (2U) – Four Brackets (4U Total); 1.75 inch Hole Spacing (N3300A) Rackmount Flange and Handle Kit 88.1 mm H (2U) – Four Brackets (4U Total); Front Handles
$
170
1CM020A
1CM020A
$
500
1CP012A
1CP012A
Each Unit Includes: Product Reference CD-ROM Including: VXIPlug&Play Drivers, User’s Guide, Programming Guide, and Application Notes.
Call
★ Recommended Transcat Calibration
Keysight N6790 Series DC Electronic Load Modules Measure More with Less. From making battery drain test analysis to measuring DC-DC converter efficiency, now you can do it with less instruments on your bench.
F
• Voltage: Up to 60V • Current: Up to 40A • Advanced Operating Modes: CV, CC, CR, CP • Arbitrary Waveform Generation • High Speed Synchronized Digitization of Voltage and Current
• Superior Command Processing Time and Current Slew Rate • USB, LAN, GPIB Interfaces Standard • N6700C Style User Interface for Ease of Use and Familiarity
• For Use with the N67XX Modular Power System Mainframes Only • Single (N6791A) or Double-Wide (N6792A) Module, 2 to 4 Modules in Mainframe (Model Dependent) • Input Power: Up to 200 Watts Sinking Power
Specifications
N6791A
N6792A
Input Ranges Current
0 - 20 A 0 - 60 V
0 - 40 A 0 - 60 V
Voltage
Maximum Power @ 40 ˚ C
100 W
200 W
Specified Current @ Low Voltage Operation: (See Output Quadrant Charismatic) 1.6 V 20 A
40 A 25 A
1 V
12.5 A 6.25 A 1.25 A
0.5 V 0.1 V
12.5 A
2.5 A
Programming Accuracy: (@ 25˚C ±5˚C After a 30 Minute Warm Up. Applies from Minimum to Maximum Programming Range at Any Load) Current High Range 20 A / 40 A 0.04% + 2.6 mA 0.04% + 5.2 mA Current Low Range 2 A / 4 A 0.04% + 0.46 mA 0.04% + 0.92 mA Voltage 60 V 0.03% + 7.2 mV 0.03% + 7.2 mV Resistance High Range 8 kOhm ± (0.1% + 0.0014) $ ± (0.1% + 0.0008) $ Resistance Medium Range 100 Ohm ± (0.1% + 0.014) $ ± (0.1% + 0.019) $ Resistance Low Range 3 Ohm ± (0.1% + 0.38) $ ± (0.1% + 0.55) $ Power High Range 100 W / 200 W 0.06% + 180 mW 0.06% + 360 mW Power Low Range 10 W / 20 W 0.06% + 30 mW 0.06% + 65 mW Measurement Accuracy: (@ 25˚C ±5˚C Applies when Measureing the Default Value of 1024 Delta Points with a 20.48 µs Time Interval) Current High Range 20 A / 40 A 0.04% + 2.4 mA 0.04% + 4.8 mA Current Low Range 2 A / 4 A 0.04% + 0.40 mA 0.04% + 0.82 mA Voltage 60 V 0.03% + 7.2 mV 0.03% + 7.2 mV Power High Range 100 W / 200 W 0.06% + 160 mW 0.06% + 320 mW Power Low Range 10 W / 20 W 0.06% + 25 mW 0.06% + 50 mW
Ordering Information
Mfg #
Description
Order # Price
$ 2,421 $ 3,073
N6791A 100 Watt Module, 60V, 20A N6792A 200 Watt Module, 60V, 40A ★ Recommended Transcat Calibration
N6791A N6792A
ED1404-2 $
333
F26
phone : 800-828-1470 fax : 800-395-0543 TRANSCAT.com • TRANSCAT.ca