2023 Master Catalog

plant maintenance & environmental EV Checker Megger ® EVCC300 Electric Vehicle Charger Checker, Type 1 & 2 Connections The new EVCC300 introduces a new and convenient way of checking Electric Vehicle charge points. A simple all in one concept provides an easy to use solution to check both the safety and operation of level 1 and two phase level 2 EV chargers.

• Checks Level 1 and Two Phase Level 2 Chargers • Checks Chargers with SAE J1772 Type 1 and Type 2 Connectors • Performs Four EV Charger Safety Checks • Performs Four EV Charger Operation Checks • Checks to See if Nuisance Tripping of GFCI is Likely to Occur • Reads Control Pilot State Response from EV Charger to IEC61851-1

NEW

Four Important Safety Checks: 1. PE Touch Pad to Check Ground Connection and Hazardous Voltages 2. PE Resistance (RPE) Test to Make Sure any Exposed Metalwork is Properly Grounded / Earthed 3. Touch Voltage Test to Ensure the Charger Ground /Earth Does Not Rise to a Hazardous Level when Charger Output is On 4. RCD / GFCI Protection Check by Timing the Device Tripping Speed. This Test Causes a Calibrated Ground / Earth Leakage Current Appropriate to the Trip Rating of the Device to Flow and Times How Long it Takes for the Device to Break the Supply. If an RCD / GFCI was to Take Too Long to Trip it Would Not Protect the Charger User from Electrocution, so it is an Important Safety Check Four Key EV Charger Operation Checks: 1. Proximity Detection Operation Check. The EVCC300 Can Check that Proximity is Detected and also Whether, when Testing a Type 1 Connection, that Latching Detection has Worked Correctly 2. Control Pilot Operation Check. Not Only Can the EVCC300 Set CP States to Operate the EV Charger, the Instrument Can Read the Response State of the Charger. The Codes A, B, C, D, E and F Can be Set by the EVCC300 and the Response of the Charger Displayed on the Instruments Color Display. The Charger PC State is Displayed Together with the Chargers Indicated Maximum Charge Current, all to IEC61851-1 Requirements 3. Control Pilot Signal Check. The EVCC300 Measures the CP Signal Voltage, Frequency and Duty Cycle. Repeated Measurements Will Highlight Instability in the Signal. 4. EV Charger Output Check. The EVCC300 Measures the Output Voltage and Frequency of the EV Charger when Charging is in Progress. When Appropriate the EVCC300 also Checks for Correct L – N Supply Polarity.

H

Supply Measurement

Voltage Range

5 V to 300 V

Each Unit Includes: Continuity/Earth Bond Lead, Blow Moulded Case, EVA-T1 Type 2 to Type 1 Connector Adaptor.

Voltage Resolution Voltage Accuracy Voltage Measurement

1 V

± 5% ± 2 Digits

L to N, L to PE and N to PE

Reverse Polarity Indication

L to N, for Single Phase Option Only

Frequency Range

45 Hz to 65 Hz

Transcat.com/megger-evcc300

Frequency Resolution Frequency Accuracy

1 Hz

± 1 Digit

H31

phone : 800-828-1470 fax : 800-395-0543 TRANSCAT.com • TRANSCAT.ca

Made with FlippingBook Ebook Creator