IR/Dry Block Calibrators
calibration instruments
Short heating and cooling times get you to temperature quickly and performs when it gets there. Fluke Calibration Portable IR Calibrators
• Certify IR Pyrometers from –30° C to 500° C (–22° F to 932° F) • Large 2.25” (57 mm) Black Body Target
• RTD Reference Well for High Precision • Small, Compact Design • Now Comes with a Radiometric Calibration
A
Specifications
Mfg #
9132
9133
Temperature Range
50°C to 500°C (122 F to 932°F) ±0.5°C at 100°C (±0.9°F at 212°F) ±0.8°C at 500°C (±1.4°F at 932°F) ±0.1°C at 100°C (±0.18°F at 212°F) ±0.3°C at 500°C (±0.54°F at 932°F)
–30°C to 150°C at 23°C Ambient (–22 to 302°F at 73°F Ambient)
Accuracy (Contact Calibration)
±0.4°C (±0.72°F)
9133
Each Unit Includes: Manufacturer’s NIST Traceable Certificate of Calibration and Instructions. The 9133 Includes a Quick-Attach Fitting on the Front Bezel for Dry Air Purging, which Eliminates Ice Buildup on the Target.
Stability
±0.1°C (±0.18°F)
Ordering Information
Target Size
2.25" (57 mm)
Mfg #
Description
Order #
Price
Target Emissivity
0.95 0.1°
$ 6,719 $ 9,497
9132 9133
Portable IR Calibrator Portable IR Calibrator
HART9132 HART9133
Resolution
Heating Time Cooling Time
30 minutes (50°C to 500°C) 30 minutes (500°C to 100°C)
15 minutes (25°C to 150°C) 15 minutes (25°C to –20°C)
★ Recommended Transcat Calibration
XX0018-6 $
354
Recommended Accessories
Computer Interface
RS-232 included with 9930 Interface-it Software
$ $
225 753
9308 9302 1523
Rugged Carrying Case for HART9132 Rugged Carrying Case for HART9133 Thermometer, Handheld, One Channel Secondary Reference PRT, 1⁄8” Diameter, -200°C to 500°C
5961T-CS HART9302
115 VAC (±10%), 3A or 230 VAC (±10%), 1.5A, Switchable, 50/60 Hz 4"H x 6"W x 7"D (102 x 152 x 178 mm)
115 VAC (±10%), 1.5A, 230 VAC (±10%), 1.0A, Switchable, 50/60 Hz
Power
$ 2,644
1523H
6"H x 11.25"W x 10.5"D (152 x 286 x 267mm)
Size
$ 1,327
5618-9-I
5618B-9
Possibly the fastest and lightest dry-block calibrator available – with the accuracy and control of a larger unit. AMETEK/JOFRA ETC Series Dry Block Calibrators
• Two Temperature Ranges and Four Models • Cooling Unit with Three Predrilled Bores and Insert Tube • Replaceable Insert Tube Adds Size Flexibility • Heating Unit with Four Predrilled Bores
• Front Panel, One Key - One Function Operation • Auto-Stepping – User Programmable • RS232 and Software • JOFRACAL – Download Routines and Results
Each Unit Includes: Dry-Block, Power Cable, Conversion Tubes (Cooling Units), Insert Removal Tool (Cooling Units), Shoulder Strap, RS232 Cable, Software for Testing and Calibration, Reference and User’s Manual and Manufacturer’s NPL Traceable Certification.
ETC
Specifications
Mfg #
ETC125A
ETC400A
Ranges @ 23°C/73°F Accuracy
-10° to 125°C, 14° to 257°F
28° to 400°C, 82° to 752°F
Ordering Information
±0.50°C / ±0.90°F ±0.05°C / ±0.09°F
±0.50°C / ±0.90°F ±0.15°C / ±0.27°F
Mfg # ETC-1 ETC-2
Description
Order #
Price
Stability
$ 4,138 $ 4,467 $ 2,870
Dry-Block Calibrator 1 x 4mm, 1 x 6mm, 1 x 8mm, 1 x 12.5mm Dry-Block Calibrator 1 x 5⁄32in, 1 x 1⁄4in, 1 x 3⁄8in, 1 x 1⁄2in
ETC125A-1 ETC125A-2
Resolution Immersion Depth
1° or 0.1°C or °F – User Selectable
110mm / 4.3in
105mm / 4.1in
ETC-11
Dry-Block Calibrator 1 x 1⁄16in, 1 x 1⁄8in, 1 x 5⁄32in, 1 x 3⁄16in, 1 x 1⁄4in
ETC400-11
Heating Time Min to Max Cooling Time Max to Min
★ Recommended Transcat Calibration
PT0904-6 $
713
21 Minutes
5 Minutes
Recommended Accessories
32 Minutes
21 Minutes
Carrying Case for ETC (Can Also Order with Unit - Use CE Instead of EX and Add $308 )
$
372
124094
124094
115 VAC or 230 VAC (60 Hz Unit) (Multiple Voltage Power Supply)
115 VAC – 230 VAC (60 Hz Unit) Available (Add -230 to Catalog Part Number)
$ $ $
177
123939 Five Pack Undrilled Insert Tubes - ETC125A 124045 3/8in Conversion Insert Tube - ETC125A 123938 8mm Conversion Insert Tube - ETC125A
123939 124045 123938
Voltage
70 70
Size/Weight
6.8 x 2.8 x 7.2”HWD / 3.9lb 6.8 x 2.8 x 7.2”HWD / 3.5lb
A20
phone : 800-828-1470 fax : 800-395-0543 TRANSCAT.com