ARFF NEWS (CONT)
STEP-BY-STEP PLAN FOR SAFE & SUSTAINABLE AVIATION
nts for
d
Analyse your emergency response plan in light of the changed use with electric aircraft. Have you informed your safety region of the changed use with electric aircraft? Based on Annex 14 Vol I Article 9.1.5 part a.
ses due to re very t of water) ings or ty of the
Analyse whether your RFFS complies with the above information. Input; at least 1,000 litres of extinguishing agent per battery pack Input; 150,000 litres per e-bus Based on Pipistrel ground information card and Netherlands Institute for Public Safety. (www.ifv.nl)
hangars e
Do you have sufficient back-up extinguishing agent for in case of a thermal runaway? And analyse if your safety region responds within 8 or 15 minutes (on average). If it is more than 8 minutes, analyse your RFFS again. Based on ICAO Annex 14 Vol I Article 9.2.25.
emely n is, to
eignition. ncidents, of ‘loose’ ehicles, an . As a imited th respect arefully parked. ay from o minimise down thought
Have you notified your safety region of the changed use with electric aircraft? Based on Annex 14 Vol I Article 9.1.5 part a.
Have you updated your task resource analysis following the changed use? Based on Annex 14 Vol I Article 9.2.45
Train your RFFS personnel for the changed use and update your training syllabus. Based on Annex 14 Vol I Article 9.2.42 and attachment A part 6.8 Annex 14 Vol I