MetLogix M2 User Manual

6 Press the Nominal button to go to the Tolerance Feature Detail screen. Tolerances from the Place Tolerance table will have been applied. 7 Press the Tolerance button to go to the Deviation Feature Detail screen and observe the results of the tolerance tests.

Place Table tolerances applied

Tolerance results

Importing Nominal Values From a DXF Drawing File (CNC systems) Nominal values for part features can be imported directly into the nominal data fields from a DXF drawing file, eliminating the need to do manual nominal data entry. Nominal values can be imported for single feature or group feature tolerancing. To import nominal values from a DXF file: 1 Press the Report button to display the Report screen and Report toolbar. System toolbar > Report button

Press the Report button

Press the Import DXF button

2 Press the Import DXF button to display the DXF Import dialog. Report toolbar > Import DXF button