HHPT
HHZ-BVT
Standard(s) IEC 60282-1
High Voltage Current-Limiting Fuses
20/36kV- Rated Voltage
without Striker For PT Transformers
Class
L = 359mm/440mm
Back-Up
Rated current
Diameter Weight
Rated Minimum breaking breaking
Power
Cold
Pre-arcing
Total I 2 t @
I 2 t
D
loss resistance
I n
0.87U n (Max)
current I 1
current I 3
>Pї@
[A 2 s]
[A 2 s]
[A 2 s]
[W]
Article Number
[in/mm]
[kg/1]
[kA]
[A]
[A]
L = 359mm
߁ ߁ ߁ ߁ ߁ ߁ ߁ ߁
߁ ߁ ߁ ߁ ߁ ߁ ߁ ߁
0.94 / 24 0.94 / 24 0.94 / 24 0.94 / 24
3.2 0.6 0.1
0.9 1.9 9.9
11 15 24 28 14 23 26 10
3038111.0.5
0.5
0.8 0.8 0.8 0.8 1.2 1.2 1.2 1.2
63 63 63 63 63 63 63 63
2.5
8
2 3038111.2 1 3038111.1 3 3038111.3
24 12
16.1
47.8
L = 440mm
3037511.1 3037511.0.5
0.5
9.9 1.9 0.9
2.5
0.6 3.2 0.1
1.56 / 39.6 1.56 / 39.6 1.56 / 39.6 1.56 / 39.6
8
1
2 3037511.2
12 24
3
3037511.3
16.1
47.8
Dimensions [mm]
20mm
14mm
Accessories
Article Description
0.94 / 24 D[in/mm]
Article Number
Page(s)
Fuse clips
9109401.3 6100201.4 6100201.3
Terminal bar for fuse clips Fuse clips Terminal bar for fuse clips
192
1.56 / 39.6
9109401.4 Contact SIBA
Fuse base
portal: www.siballc.net e-mail: info@sibafuse.com
140
Made with FlippingBook - Online magazine maker