V

V

Rated Voltage Rated Breaking Capacity

Standard(s) DIN 72581-part 2

[Un]

36V DC 80V DC

Size - Form A - Open Frame, Frame B - Enclosed Form

Current Rated

80V DC Form B

Cold Power

Form A 36V DC

Resistance Loss  [W] 1.4 1.75

Weight [kg / 100]

I n [A]

Article Number 9005409.25 9005409.30 9005409.35 9005409.40 9005409.50 9005409.63 9005409.80

Article Number

9005409 0.025 0.025 0.025 0.025

0.39 0.39 9005909

9005909.125 9005909.150 9005909.100 9005909.25 9005909.30 9005909.35 9005909.40 9005909.50 9005909.63 9005909.80

25 30 35 40 50 63 80

1.9 2.2 1.8 3.1 3.6 5 6.0 6.7 7.4

1.62 1.50 0.96 0.96 0.71 0.57 0.45 0.37 0.24

0.49 0.49 0.39 0.39 0.39 0.39 0.39 0.39

0.05 0.05 0.11

0.4 0.4 0.4

9005409.100 9005409.125 9005409.150

100 125 150

Units per Package

100

40

Time-Current Characteristics

9005409

R.M.S. Prospective Current [A]

9005909

portal: www.siballc.net e-mail: info@sibafuse.com