Catálogo fusibles SIBA 2022

GSS

Rated Breaking Test

Class

GSMB

Rated Voltage

IEC 60127-4 Standard(s)

[Un]

F

Voltage 250V AC

Capacity



250V AC

100A

Power 4.5mmx8mm - Ceramic tube w/ filler, contacts - brass - silver plated Rated Rated Voltage Pre-arcing

Approvals

Time-Current Characteristics

dissipation @ 1.25I n

current

breaking current

drop

I 2 t

I n

[A 2 s] 0.076 0.19

[A]

161000.0.630 161000.0.800 Article Number 161000.0.500

100A @ 250V AC 100A @ 250V AC 100A @ 250V AC 100A @ 250V AC 100A @ 250V AC 100A @ 250V AC 100A @ 250V AC 100A @ 250V AC 100A @ 250V AC 100A @ 250V AC 100A @ 250V AC [A] 100A @ 250V AC

200 [mV] 180

[mW]

700 600 400 400 500 300 300 300 300

1 0.800 0.630 0.500

160 140 140 120 110 100 100 100 100 100

0.38 0.71 0.94 0.56 1.1

161000.1 161000.1.25 161000.1.6 161000.2 161000.2.5 161000.3.15 161000.4 161000.5 161000.6.3

1.25

1.6

2

2.5

2.0 3.2 5.0 9.0

3.15

1 400 900 1 000

6.3 5 4m

13

Tape reel ordering, add following suffix to article number GT - (1 500 pieces on tape reel) e.g. 161000.1.6GT

I

I rat.

Dimensions

[mm]

+ 8. 0 -

0.5 0.25

9.2

2.2

4.4

4.4

5.6

2.8

2.8

Recommended pad layout

Fusing Time Limits

1.25I n

4I n

2I n

2.75I n

10I n Min Max    

Rated current

Max

Min

Min

Min Max Min

Max

Max











 



500mA - 6.3A 1h

Resistance to soldering heat, 260°C, 10s, solder bath

( to IEC 60068-2 -58)

portal: www.siballc.net e-mail: info@sibafuse.com

634

Made with FlippingBook - Online magazine maker