GSS
Rated Breaking Test
Class
GSMB
Rated Voltage
IEC 60127-4 Standard(s)
[Un]
F
Voltage 250V AC
Capacity
250V AC
100A
Power 4.5mmx8mm - Ceramic tube w/ filler, contacts - brass - silver plated Rated Rated Voltage Pre-arcing
Approvals
Time-Current Characteristics
dissipation @ 1.25I n
current
breaking current
drop
I 2 t
I n
[A 2 s] 0.076 0.19
[A]
161000.0.630 161000.0.800 Article Number 161000.0.500
100A @ 250V AC 100A @ 250V AC 100A @ 250V AC 100A @ 250V AC 100A @ 250V AC 100A @ 250V AC 100A @ 250V AC 100A @ 250V AC 100A @ 250V AC 100A @ 250V AC 100A @ 250V AC [A] 100A @ 250V AC
200 [mV] 180
[mW]
700 600 400 400 500 300 300 300 300
1 0.800 0.630 0.500
160 140 140 120 110 100 100 100 100 100
0.38 0.71 0.94 0.56 1.1
161000.1 161000.1.25 161000.1.6 161000.2 161000.2.5 161000.3.15 161000.4 161000.5 161000.6.3
1.25
1.6
2
2.5
2.0 3.2 5.0 9.0
3.15
1 400 900 1 000
6.3 5 4m
13
Tape reel ordering, add following suffix to article number GT - (1 500 pieces on tape reel) e.g. 161000.1.6GT
I
I rat.
Dimensions
[mm]
+ 8. 0 -
0.5 0.25
9.2
2.2
4.4
4.4
5.6
2.8
2.8
Recommended pad layout
Fusing Time Limits
1.25I n
4I n
2I n
2.75I n
10I n Min Max
Rated current
Max
Min
Min
Min Max Min
Max
Max
500mA - 6.3A 1h
Resistance to soldering heat, 260°C, 10s, solder bath
( to IEC 60068-2 -58)
portal: www.siballc.net e-mail: info@sibafuse.com
634
Made with FlippingBook - Online magazine maker