GSS
GZ
Rated Breaking Test
FF Class
Rated Voltage
Standard(s) Special Type
[Un]
Voltage 250V AC
Capacity
250V AC
200kA / 1.5kA
E180276
5mmx20mm - Ceramic tube w/ filler, end caps - brass, nickel plated
Power
Rated current
Rated
Voltage
Pre-arcing Approvals
Time-Current Characteristics
current breaking
drop
dissipation I 2 t
I n [A]
@ 1.0I n
UL rec
0.004 0.0024 0.0016 [A 2 s]
7000140.1.25 7000140.0.800 7000140.1 7000140.0.250 7000140.0.315 7000140.0.400 7000140.0.500 7000140.0.630 7000140.1.6 7000140.2 7000140.2.5 7000140.3.15 7000140.4 7000140.5 7000140.6.3 7000140.8 7000140.10 7000140.12.5 7000140.0.200 Article Number 7000140.0.100 7000140.0.125 7000140.0.160
200kA @ 250V AC 200kA @ 250V AC 200kA @ 250V AC 200kA @ 250V AC 200kA @ 250V AC 200kA @ 250V AC 300kA @ 250V AC 200kA @ 250V AC 200kA @ 250V AC 200kA @ 250V AC 200kA @ 250V AC 200kA @ 250V AC 1.5kA @ 250V AC 1.5kA @ 250V AC 200kA @ 250V AC 1.5kA @ 250V AC 1.5kA @ 250V AC 200kA @ 250V AC 200kA @ 250V AC 200kA @ 250V AC 200kA @ 250V AC [A] 200kA @ 250V AC
[mV] 1 000 95 0 1 300
[mW]
0. 1
0.630 0.800 0.400 0.500 0.315 0.100 0.125 0.160 0.200 0.250
0. 12
0.2 0.2 0.2 0.3
350 350 300 300 300 200 400 600 400 600 600 500 550 600 550 500 400 400 400
0.01 0.02 0.04
0.32 0.32 0.5 0.20 0.2 0.07 0.3 0.07 0.4 0.15 1.3 1.6 0.8 0.64 1.0 0.88 0.7 0.31 0.5 0.6
1
1.25
2.5 1.6 2
3.15
4
5.9 3.2
1.9 2.4 3.0 1.4 1.8 2.5
5 6.3
I
30 19 10
I rat.
8 10
115
12.5
Weight (kg per 100) 0.14 Units per package 10
For 6.3A and higher, consideration should be given to heat dissipation
e.g. 7000140.3.15IP IP - (1 000 pieces)
Dimensions
[mm]
5.2 +0.1 Ø -0.2
20
±
0.5
Fusing Time Limits
1I n
2I n
2.75I n
4I n
10I n
Rated current
Max
Min
Min
Max Min
Max
Max
Min
Min
6ms Max 3ms
60ms
100mA - 800 m A 1h 1A - 12.5A 1h
4ms 100ms
1ms
25ms
portal: www.siballc.net e-mail: info@sibafuse.com
643
Made with FlippingBook - Online magazine maker