RV_910047_Catalog

Air heaters Air Top Evo 40/55

Technical Specifications Air Top Evo 40/55

Air Top Evo 40

Air Top Evo 55

ECE approval number ECE R122 (​heating)

E1 00 0385

E1 00 0386

ECE approval number ECE R10 (EMC)

E1 04 5529

E1 04 5529

Heating capacity, control range / boost

5,100 – 12,000 / 13,650 BTU/h (1.5 – 3.5 / 4.0 kW)

5,800 – 12,000 / 13,650 BTU/h (1.7 – 3.5 / 4.0 kW)

5,100 – 17,000 / 18,800 BTU/h (1.5 – 5.0 / 5.5 kW)

5,800 – 17,000 / 18,800 BTU/h (1.7 – 5.0 / 5.5 kW)

Fuel consumption, control range/boost

0.05 – 0.11 / 0.13 gal/h (0.18 – 0.43 / 0.49 l/h)

0.07 – 0.14 / 0.15 gal/h (0.25 – 0.51 / 0.58 l/h)

0.05 – 0.16 / 0.18 gal/h (0.18 – 0.61 / 0.67 l/h)

0.07 – 0.19 / 0.21 gal/h (0.25 – 0.73 / 0.80 l/h)

Nominal voltage

12 V

24 V

12 V

12 V

24 V

12 V

Rated power consumption, control range/boost @ 12 V

1.25 –3.3 / 4.58 Amps (15 – 40 / 55 W)

1.25 –7.9 / 10.8 Amps (15 – 95 / 130 W)

Heating air volume flow against 0.5 mbar, ​ control range / boost

77.7 / 82.4 cfm (132 / 140 m 3 / h)

117 / 129.5 cfm (200 / 220 m 3 / h)

Fuels

Diesel

Gasoline

Diesel

Gasoline

Operating temperature range

–40 to +104 °F (–40 to +40 °C)

–40 to +104 °F (–40 to +40 °C)

Dimensions (L x W x H)

16.7 x 5.8 x 6.4 in (423 x 148 x 162 mm)

16.7 x 5.8 x 6.4 in (423 x 148 x 162 mm)

Weight

13 lbs (5.9 kg)

13 lbs (5.9 kg)

System Schematic Air Top Evo 40/55

Kit Components Air Top Evo 40/55: n Heater n Fuel Pump n Base Seal

n Heater Wire Harness n Fuel Pump Harness n Fuel Line

n Fuel Standpipe n Exhaust Tubing n Flexible Stainless Steel Exhaust pipe n Combustion Air Tubing n Flexible Ducting (Diesel Kits Only) n Air Outlets n Operation/Installation Manual  2 year limited warranty (2,000 hours)

1. Air Top Evo 40/55 Heater 2. Control Dial 3. Cold Air Inlet 4. Hot Air Outlet/Ducting 5. Combustion Air Inlet

6. Exhaust Outlet 7. Fuel Metering Pump 8. Fuel Filter 9. Fuel Standpipe

25