Emergency Power Supply (UPS) Section Summary Emergency power supply, or Uninterrupted Power Supply (UPS) for SDA dwellings only. SDA Power and Data Considerations Checklist: • Refer to NDIS SDA Design Standard for guidance. • UPS unit is preferred emergency power solution • Emergency power solution provides power (minimum) within each SDA dwelling to: • DGPO on either side of participant bed;
D3.05 Power and data cont... • Hallways ○ 1 DGPO.
• Kitchen ○
2 DGPOs (minimum) in kitchen: at least 1 DGPO shall be within 300mm forward reach from the front edge of the bench.
• Living ○
1 TV outlet.
○ ○
2 DGPOs on wall in likely TV location. 1 data point on wall in likely TV location.
• Any automated doors along the path of egress; and • Lighting required to facilitate safe egress from dwelling.
• Dining ○
• Emergency power solution is to provide continuous power backup (no warm-up or lag-time) to ensure essential services are continually available. • Hardware for emergency power solutions are to be discretely located, but readily accessible for servicing requirements.
1 DGPO.
• Bathroom ○
1 DGPO adjacent to vanity.
○ Power pre-wiring (capped GPO) provided adjacent to toilet to allow future bidet installation.
• Laundry ○
2 DGPOs.
• Bedroom 1 ○
2 DGPOs on either side of bed location (1x DGPO with USB outlet each side). ○ 1 DGPO on wall opposite bed location. ○ 1 GPO to bedroom ceiling. ○ 1 TV outlet on wall opposite bed location. ○ 1 data point on wall opposite bed.
Note: All GPOs to be large format (min. width 35mm) and located at an accessible height as per NDIS SDA Design Standard.
74
Housing Choices Australia | Design Guidelines