Lookout No Garage

Branch Panel:

MAIN PANEL CALCS

ELECTRICAL NOTES

Location: KITCHEN 3

Volts: 120/240 Single

Mains Type: A.I.C. Rating:

Supply From:

Wires: 3 Phases: 1

Tuscon,AZ, USA 888-864-0184 inquire@frameupnow.com www.frameupnow.com

ELECTRICAL CALCS LIGHT AND OUTLETS 895 @ 3W 2685 W 3 APPLIANCE CIRCUITS 4500 W DRYER 5000 W WASHER 1500 W WATER HEATER 5000 W REFRIG. 1500 W DISPOSAL 1500 W

1.

THIS DRAWING DEPICTS THE ELECTRICAL SYSTEM FOR THE LOOKOUT_NG_350. IT PROVIDES A VISUAL REPRESENTATION OF THE ELECTRICAL LAYOUT AND COMPONENTS, INCLUDING POWER DISTRIBUTION, LIGHTING, AND CONTROL SYSTEMS. THE ELECTRICAL SYSTEM IS DESIGNED TO MEET THE SPECIFIC REQUIREMENTS OF THE BUILDING, INCLUDING POWER DISTRIBUTION, LIGHTING, AND SPECIALIZED ELECTRICAL EQUIPMENT NEEDS, AS PER THE PROJECT SPECIFICATIONS AND APPLICABLE CODES AND STANDARDS. THE ELECTRICAL SYSTEM INSTALLATION SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE (NEC), INTERNATIONAL BUILDING CODE (IBC), AND ALL OTHER APPLICABLE LOCAL, STATE, AND NATIONAL CODES AND REGULATIONS. LOCATIONS AS NEEDED, DEVICES ARE SHOWN ON PLANS IN APPROXIMATE IDEAL LOCATIONS, UNLESS SPECIFICALLY DIMMENSIONED. OPEN WALLS AS NEEDED TO ALLOW FOR NEW ELECTRICAL INSTALLATIONS. LABEL ALL CIRCUITS ON JUNCTION BOXES, RECEPTACLES,DATA, SMOKE DETECTOR, AND EQUIPMENT IN PANEL BOX. INSTALL RACEWAY AS NEEDED FOR DDC, ACCESS CONTROL, LOW VOLTAGE WIRING & DATA. RELABEL POWER, DATA & FIRE ALARM FOR ROOM #CHANGES. VERIFY ALL CIRCUITS LABELED ON PRINT ARE CORRECT BEFORE WORKING ON THEM. NOTE ON SITE PLAN – ALL CHANGES OR MISSING DETAIL TO BE INCORPORATED INTO THE MASTER PLAN. DRAWINGS ARE DIAGRAMMATIC ONLY FOR THE PURPOSE OF SHOWING FIXTURE AND OUTLET LOCATIONS. ELECTRICAL CONTRACTOR TO VERIFY SERVICE SIZE BY CALCULATION BASED UPON ACTUAL NAME PLATE RATINGS OF SELECTED EQUIPMENT. VERIFY LOCATION OF SERVICE ENTRANCE WITH POWER COMPANY. PROVIDE UFER GROUND IN BUILDING FOUNDATION AT SERVICE ENTRANCE LOCATION. PROVIDE A MIN. OF 20 FEET OF ONE *4 BARE COPPER UFER WIRE EMBEDDED IN CONCRETE FOOTING AT THE SERVICE ENTRANCE LOCATION WHERE APPROVED BY LOCAL SERVICE PROVIDER. PROVIDE WATERPROOF FIXTURES IN ALL HIGH MOISTURE AREAS (EXTERIOR, SHOWER AND TUB CEILINGS ETC.) PROVIDE DEDICATED CIRCUITS TO EACH BATH, DEN, FAMILY ROOM, BEDROOM, LOFT, KITCHEN REFRIGERATOR, KITCHEN FREEZER DISHWASHER, AND ANY AREA/ITEM SPECIFIED BY OWNER. INCANDESCENT FIXTURES WITH OPEN OR PARTIALLY ENCLOSED LAMPS, PENDANT FIXTURES, AND LAMP HOLDERS ARE NOT PERMITTED IN CLOSETS. ALL WORKMANSHIP AND MATERIALS TO CONFORM WITH THE 2015 IRC. PROVIDE A MIN. OF 20 FEET OF ONE *4 BARE COPPER UFER WIRE EMBEDDED IN CONCRETE FOOTING AT THE SERVICE ENTRANCE LOCATION WHERE APPROVED BY LOCAL SERVICE PROVIDER. PROVIDE A BONDING CONDUCTOR CONSISTING OF A MINIMUM OF ONE *4 BARE COPPER WIRE CONNECTING THE BUILDING'S METAL WATER PIPING SYSTEM TO THE SERVICE EQUIPMENT ENCLOSURE GROUNDING.

Enclosure: Type 1 Mounting: Recessed

MCB Rating: 1 A Mains Rating: 200 A

2.

Notes:

3.

Circu it Nu...

Circu it Nu...

Length Wire Size

Wire Size Length

Circuit Description

Circuit Description

Number of Elements Rating

Number of Elements

AA, Ethiopia Info@housedocs.store www.housedocs.store

A

B

C

Rating

4. 5. 6. 7. 8. 9.

1-#4, 1-#4, 1-#4

1-#12, 1-#12, 1-#12

720 VA

1

5

20 A 39' - 11 23/32"

7500 VA

45' - 6 7/32"

20 A

4

2

RECEPTACLE

OUTDOOR GFCI

2-#8, 1-#8, 1-#10 1-#12, 1-#12, 1-#12

1-#4, 1-#4, 1-#4

1500 VA

6000 VA

3

1

20 A 26' - 7 11/32"

57' - 2 3/32"

20 A

4

4

REFRIGIRATOR

Receptacle

KEY PLAN

2-#10, 1-#10, 1-#10 1-#14, 1-#14, 1-#14 1-#12, 1-#12, 1-#12

923 VA

5

1

40 A 20' - 8 5/32"

2500 VA

57' - 6 15/16"

15 A

9

6

RANGE

LIGHTS

10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20.

2500 VA

LIGHTING - DWELLING UNIT

TOTAL

21,685 W

7

--

--

--

--

399 VA

51' - 0 3/32"

15 A

12

8

--

2-#10, 1-#10, 1-#10 1-#12, 1-#12, 1-#12

WASHING MACHINE

2500 VA

9

1

20 A 13' - 1 19/32"

1500 VA

11' - 0 25/32"

30 A

1

10

DRYER

FRIST 10,000 @ 100% REMAINDER @ 40% MINI. SPLIT UNITS

10,000 W 4,674 W 10,000 W

2500 VA

2500 VA

11 WATER HEATER

1

30 A 34' - 7 21/32"

--

--

--

--

12

--

2-#10, 1-#10, 1-#10 1-#12, 1-#12, 1-#12 1-#12, 1-#12, 1-#12

720 VA

KITCHEN RECEPTACLE

13 --

--

--

--

--

2500 VA

24' - 3 1/2"

20 A

4

14

TOTAL

24,674 W

2-#6, 1-#6, 1-#10 1-#12, 1-#12, 1-#12

NO.

DESCRIPTION

DATE

KITCHEN LIGHTING

15 BATH GFCI

7

20 A 51' - 10"

319 VA 240 VA

35' - 2 3/8"

20 A

4

16

24,674 W DIVIDED BY 240V = 103 AMPS TOTAL

2500 VA

17 CONDENSER

1

60 A 28' - 1 7/32"

750 VA

18' - 9 1/2"

30 A

1 AIR HANDLER 18

(USE 200 AMP SERVICE)

2500 VA

19 --

--

--

--

--

750 VA

--

--

--

--

--

20

21

22

23

24

NOTE:

25

26

ELECTRICAL ABBREVIATIONS LIST

22105 VA

19180 VA

0 VA

184 A

160 A

0 A

Legend:

1P A AC ACLG ADO AF

1 POLE (2P, 3P, 4P, ETC.) AMPERE ABOVE COUNTER OR AIR CONDITIONER ABOVE CEILING AUTOMATIC DOOR OPENER AMP FRAME ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ARC FAULT CIRCUIT INTERRUPTER AIR HANDLING UNIT ALUMINUM ALTERNATE AMPERE AMPLIFIER ANNUNCIATOR APPROX APPROXIMATELY AQUASTAT ARCHITECT, ARCHITECTURAL AMP SWITCH AMP TRIP AUTOMATIC TRANSFER SWITCH AUTOMATIC AUXILIARY AUDIO VISUAL AMERICAN WIRE GAUGE BATTERY BOARD BUILDING BUILDING MANAGEMENT SYSTEM

CTR CU DCP DEPT DET DIA DISC DIST DN DPR DS DT DWG DDC EC ELEC ELEV EM EMS EMT EP EQUIP EWC EXIST

CENTER COPPER DOMESTIC WATER CIRCULATING PUMP DEPARTMENT DETAIL DIAMETER DISCONNECT DISTRIBUTION DOWN DAMPER SAFETY DISCONNECT SWITCH DOUBLE THROW DRAWING DIRECT DIGITAL CONTROL ELECTRICAL CONTRACTOR ELECTRIC, ELECTRICAL ELEVATOR EMERGENCY ENERGY MANAGEMENT SYSTEM ELECTRICAL METALLIC TUBING ELECTRIC PNEUMATIC EQUIPMENT ELECTRIC WATER COOLER EXISTING EXHAUST EXPLOSION PROOF FIRE ALARM FIRE ALARM BOOSTER POWER SUPPLY PANEL FIRE ALARM CONTROL PANEL FAN COIL UNIT FIXTURE FLOOR FLUORESCENT FUSE FUSED SAFETY DISCONNECT SWITCH GAUGE GALLON GALVANIZED GENERAL CONTRACTOR GENERATOR GROUND FAULT CIRCUIT INTERRUPTER GROUND FAULT PROTECTOR GROUND GALVANIZED RIGID STEEL (CONDUIT) GYPSUM BOARD

HT HTG HTR HV HVAC CONDITIONING HWP

HEIGHT HEATING HEATER HIGH VOLTAGE HEATING, VENTILATING AND AIR CONDITIONING HYDRONIC WATER PUMP INTERRUPTING CAPACITY ISOLATED GROUND INTERMEDIATE METAL CONDUIT INCANDESCENT INFRARED INTERLOCK WITH JUNCTION BOX KILOVOLT KILOVOLT-AMPERE KILOVOLT-AMPERE REACTIVE KILOWATT KILOWATT HOUR LOCATE OR LOCATION LIGHT LIGHTING LIGHTNING LOW VOLTAGE MAXIMUM MAGNETIC STARTER MOMENTARY CONTACT MECHANICAL CONTRACTOR MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MAIN DISTRIBUTION CENTER MAIN DISTRIBUTION PANEL MANUFACTURERMAIN FUSED DISCONNECT SWITCH MANHOLE MICROPHONE MINIMUM MANUAL MOTOR STARTER MULTIOUTLET ASSEMBLY MOTOR STARTER PANELBOARD MAIN SWITCHBOARD MOUNT EMPTY CONDUIT UNDERWRITERS LABORATORIES MISCELLANEOUS MAIN LUGS ONLY

Lighting - Dwelling Unit Load Classification

Connected Load Demand Factor Demand Factor Estimated Demand Estimated Demand

Panel Totals

724 VA

100.00% 100.00% 100.00% 80.00% 100.00% 100.00% 100.00% 83.07% 100.00% 125.00% 100.00%

724 VA

1500 VA 5000 VA 5000 VA 5000 VA 5000 VA 1500 VA 300 VA 15120 VA 690 VA 1500 VA

1500 VA 5000 VA 5000 VA 4000 VA 5000 VA 1500 VA 300 VA 12560 VA 690 VA 1875 VA

Total Est. Demand: 38099 VA Total Conn. Load: 41284 VA

Other Motor

LEGEND:

Total Conn.: 172 A

Receptacle

Total Est. Demand: 159 A

Lighting

AFF AFG AFI AHU AL ALT AMP AMPL ANNUN AQ-STAT ARCH

CONDENSER

IC IG IMC INCAND IR I/W J-BOX KV KVA KVAR KW KWH LOC LT LTG LTNG LV MAX MAG.S M/C MC

WATER HEATER

DRYER RANGE

Notes: REFRIGERATOR AIR HANDLER

AS AT ATS AUTO AUX AV AWG BATT BD BLDG BMS C CAB CAT CATV CB CCTV

PROJECT

EXH EXP FA FABP SUPPLY PANEL FACP

LOOKOUT_NG_350

CONDUIT CABINET CATALOG

MCB MCC MDC MDP MFR MH MIC MIN MISC MLO MMS MOA MSP MSBD MT MT.C UL

FCU FIXT FLR FLUOR FU FUDS GA GAL GALV GC GEN GFI GFP GND GRS GYP BD

CABLE TELEVISION CIRCUIT BREAKER CLOSED CIRCUIT TELEVISION

DRAWING NAME

SCHEDULE

CKT CLG

CIRCUIT CEILING

COMB CMPR CONN CONST CONT CONTR CONV CP CRT CT

COMBINATION COMPRESSOR CONNECTION CONSTRUCTION CONTINUATION OR CONTINUOUS CONTRACTOR CONVECTOR CIRCULATING PUMP CATHODE-RAY TUBE CURRENT TRANSFORMER

Owner 0021_15

DATE: PROJECT NUMBER: DESIGNED BY: CLIENT NAME:

7/30/2024 3:49:38 AM

Designer Author Checker

CHECKED BY: DRAWN BY:

E101

SCALE:

1/4" = 1'-0"

© [2024] [FrameUpNow] [HouseDocs]. All rights reserved