Lookout No Garage

RCA 223

RCA 223

350S 33mil 50ksi TRUSS

TIE PLATE

350S 33mil 50ksi

SHEATHING MATERIAL 1/2" OSB

2X6 RAFTERS @ 2' O.C. W/ 1/2" OSB W/ 1/2" MOISTURE RESISITANT DRYWALL

TRUSS

350S 33mil 50ksi

TRUSS

350S 33mil 50ksi LE BLOCKING

SOFFIT

350S 33mil 50ksi SHEET ROCK

(RECOM) RCA 223 RIGID CONNECTOR (OPTIONAL) S/H2.5 CONNECTOR WITH #10 SCREWS

STAGGER FASTENERS IN 2 ROWS

LAG SCREW OR BLOT

SHEATHING MATERIAL 1/2" OSB

LEDGER

2X6 LE RAF.

350S 43mil 50ksi Beam

PANEL FIELD SCREW AT 1'-0" O.C. EA. STUD #6 SCREW MIN.

SOFFIT BOARD

DRIP PROFILE 2X6 FASCIA

18 Ga

2X6 FASCIA

TIE PLATE CONNECTOR WITH #10 SCREWS

350 S 33mil 50ksi CEILING FRAMING

SOFFIT

350S 33mil 50ksi LE BLOCKING

3

6ft Plus

(RECOM) RCA 223 RIGID CONNECTOR (OPTIONAL) S/H2.5 CONNECTOR WITH #10 SCREWS

4X6 POST

END STUD

2-#8 AT 2'-0" O.C. SCREW

(RECOM) RCA 223 RIGID CONNECTOR (OPTIONAL) S/H2.5 CONNECTOR WITH #10 SCREWS

DISTANCE SHALL BE PERMITTED TO BE REDUCED TO 4.5" IF LAG SCREWS ARE USED OR BOLT SPACING IS REDUCED TO THAT OF LAG SCREWS TO ATTACH METAL LEDGERS TO METAL BAND JOISTS.

10 BEAM / RAFTER CONN.

11

12

13

14

LEDGER

SOFFIT / FASCIA BOARD CONNECTION

BEAM / TRUSS CONN.

STUD BRACING WITH SHEATHING

TIE PLATE

TIE PLATE

RCA 223

RCA 223

TIE PLATE

S/LS50 CONNECTOR

TIE PLATE

RCA 223

550S 43mil 50ksi HORIZONTAL MEMBER

(RECOM) RCA 223 RIGID CONNECTOR WITH #10 SCREWS

350S/550S 33mil 50ksi DIAGONAL MEMBER

(RECOM) RCA 223 RIGID CONNECTOR WITH #10 SCREWS

TIE PLATE CONNECTOR WITH #10 SCREWS

10g-19mm X-Drive SCREWS

(RECOM) RCA 223 RIGID CONNECTOR WITH #10 SCREWS

550S 43mil 50ksi DIAGONAL MEMBER

550S 43mil 50ksi DIAGONAL MEMBER

TIE PLATE CONNECTOR WITH #10 SCREWS

350S/550S 33mil 50ksi DIAGONAL MEMBER

S/LS CONNECTOR WITH #10 SCREWS

550S 43mil 50ksi VERTICAL MEMBER

550S 43mil 50ksi DIAGONAL MEMBER

TIE PLATE CONNECTOR WITH #10 SCREWS

550S 43mil 50ksi VERTICAL MEMBER

550S 43mil 50ksi HORIZONTAL MEMBER

CEILING

S/LS CONNECTOR WITH #10 SCREWS

VERTICAL POST

(RECOM) RCA 223 RIGID CONNECTOR (OPTIONAL) S/H2.5 CONNECTOR WITH #10 SCREWS

10g-19mm X-Drive SCREWS

TIE PLATE CONNECTOR WITH #10 SCREWS

4x6 POST

TIE PLATE CONNECTOR WITH #10 SCREWS

CEILING BORED

(RECOM) RCA 223 RIGID CONNECTOR WITH #10 SCREWS

350S/550S 33mil 50ksi VERTICAL MEMBER

TIE PLATE CONNECTOR WITH #10 SCREWS

(RECOM) RCA 223 RIGID CONNECTOR (OPTIONAL) S/H2.5 CONNECTOR WITH #10 SCREWS

4x6 POST

FC 32-5/97 CONNECTOR WITH #10 SCREWS

350S/550S 33mil 50ksi VERTICAL MEMBER

FC 32-5/97 CONNECTOR WITH #10 SCREWS

TIE PLATE CONNECTOR WITH #10 SCREWS

550S 43mil 50ksi VERTICAL MEMBER

350S/550S 33mil 50ksi HORIZONTAL MEMBER

TIE PLATE CONNECTOR WITH #10 SCREWS

350S/550S 33mil 50ksi HORIZONTAL MEMBER

4x6 POST

T CONNECTION WITHOUT POST

15

16

17

18

19

BEAM TO BEAM CORNER CONNECTION

BEAM TO BEAM L-CONNECTION

BEAM OVER BEAM CONNECTION

BEAM TO BEAM T-CONNECTION

ADJACENT BEAM TO POST CONNECTION

TIE PLATE

TIE PLATE

TIE PLATE

RCA 223

Truss

8 3 16 "

8 3 16 "

STC Connector

LAPPED ASSEMBLY BEAM

TIE PLATE CONNECTOR WITH #10 SCREWS

550 S 43mil 50ksi

Truss

LAPPED ASSEMBLY BEAM

Tolerance Of 1/2" for non load bearing effect

10g-19mm XDrive SCREWS

TIE PLATE CONNECTOR WITH #10 SCREWS

STC CONNECTOR

Top Chord

TIE PLATE CONNECTOR WITH #10 SCREWS

Ceiling Panel

(RECOM) RCA 223 RIGID CONNECTOR (OPTIONAL) S/H2.5 CONNECTOR WITH #10 SCREWS

Wall Panel

Pre-Manufactured BEAM 550S 162 43mil 50ksi

Non Load Bearing Wall

LAPPED ASSEMBLY BEAM

550 S 43mil 50ksi

Connector STC

BEAM ASSEMBLY 550 S 43mil 50ksi

FASTENERS IN THE CEILING ARE HELD BACK 8" TO 12" FROM THE NEAREST CORNER

TIE PLATE CONNECTOR WITH #10 SCREWS

WALL PANEL

Truss Bottom Chord STC CONNECTOR Ceiling Panel

1/2" CORNER BACK CLIP

TIE PLATE CONNECTOR WITH #10 SCREWS

WALL PANEL

1/2" CORNER BACK CLIP

To allow for vertical truss movement,screws into the truss or raftershould not be driven completelyflush against the connector

Wall Panel

Non Load Bearing Wall

WALL PANEL

Load Bearing Wall

Non Load Bearing Wall

WALL PANEL

WALL PANEL

20

21

22

23

24

DRYWALL CLIP/CEILING BOARD CONNECTION

ADJACENT WALL TO BEAM CONNECTION

WALL TO BEAM L- CONNECTION

WALL TO BEAM T- CONNECTION

TRUSS TO NON LOAD-BEARING WALL CONNECTION

LOOKOUT_07-20-23

SCALE

DRAWN

DATE DRAWN 01-27-2024

JOB REFERENCE

REVISION

JOB DETAILS

A1

1/4" : 1'-0"

BA

ADDRESS

DWG FILE

VIEW NAME 12 of 17

ON

The_Lookout_350_8-7-24_4.6_ES

36 x 24

COLD FORMED STEEL SKELETON ONLY

Made with FlippingBook Online newsletter maker