Lookout No Garage

ROOF BRACING NOTES

2- ROOF TRUSS BRACINGS MADE UP OF 350 S 18 G FLAT STRAP 1- ALL DIMENTIONS ARE IN INCHE, DIMENTIONS TO BE VERTIFIED W/ARCH. DRAWINGS

LEGEND;-

-ROOF TRUSS BARCE -ROOF TRUSS

TRUSS BRACING TRUE LENGTH

TRUSS HEIGHT EXCLUDING HEEL HEIGHT

1/2 HALF OF THE TRUSS WIDTH XX'-YY"

ST-1

TRUSS BRACING SCHEDULE

ST-1

ST-1

QTY

ST-7 ST-6 ST-5 ST-4 ST-3 ST-2 ST-1 STRAP NO

STRAP LENGH (inche)

2 4

29' 3-5/16"

17' 10-13/16"

1 1 1 1

25' 3-7/8" 8' 11-4/16" 11' 2-1/4" 11' 2-3/4" 8' 5-15/16"

2

ST-2

ST-1

ST-1

ST-2

ST-3

ST-4

ST-7

ST-7

ST-5

ST-6

Roof Bracing Scale- 1/4": 1'-0"

LOOKOUT_07-20-23

SCALE

DRAWN

DATE DRAWN 01-27-2024

JOB REFERENCE

REVISION

JOB DETAILS

S11

1/4" : 1'-0"

BA

ADDRESS

DWG FILE

VIEW NAME 16 of 17

ON

The_Lookout_350_8-7-24_4.6_ES

36 x 24

COLD FORMED STEEL SKELETON ONLY