Lookout No Garage

HVAC Color scheme

SUPPLY AIR SYSTEM RETURN AIR SYSTEM EXHAUST AIR SYSTEM

GENERAL NOTES

Tuscon,AZ, USA 888-864-0184 inquire@frameupnow.com www.frameupnow.com

1. THIS DRAWING DEPICTS THE HVAC (HEATING, VENTILATION, AND AIR CONDITIONING) SYSTEM FOR THE LOOKOUT_NG. IT PROVIDES A VISUAL REPRESENTATION OF THE SYSTEM LAYOUT AND COMPONENTS. 2.THE HVAC SYSTEM IS DESIGNED TO MEET THE SPECIFIC REQUIREMENTS OF THE BUILDING, INCLUDING HEATING, COOLING, AND VENTILATION NEEDS, AS PER THE PROJECT SPECIFICATIONS AND APPLICABLE CODES AND STANDARDS. 3. THE HVAC SYSTEM INSTALLATION SHALL COMPLY WITH THE LATEST EDITION OF THE INTERNATIONAL MECHANICAL CODE (IMC), INTERNATIONAL RESIDENTIAL CODE (IRC), AND ALL OTHER APPLICABLE LOCAL, STATE, AND NATIONAL CODES AND REGULATIONS. 4. THE EQUIPMENT SHOWN ON THIS DRAWING INCLUDES BUT IS NOT LIMITED TO AIR HANDLING UNITS (AHUS), CHILLERS, BOILERS, COOLING TOWERS, PUMPS, DUCTWORK, DIFFUSERS, GRILLES, AND CONTROL DEVICES. 5. ALL EQUIPMENT, DUCTWORK, AND PIPING SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS, LOCAL CODES, AND INDUSTRY BEST PRACTICES. 6. ALL DUCTWORK SHALL BE SIZED, FABRICATED, AND INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE ACCA MANUAL D AND THE SMACNA HVAC DUCT CONSTRUCTION STANDARDS. DUCTWORK SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, PROPERLY SUPPORTED AND BRACED TO PREVENT SAGGING, AIR LEAKAGE, OR VIBRATION. 7. CONDENSATE DRAINAGE PIPING SHALL BE PROPERLY PITCHED TO ENSURE POSITIVE DRAINAGE TO AN APPROVED DISPOSAL LOCATION, SUCH AS A FLOOR DRAIN, SUMP PUMP, OR EXTERIOR GRADE. CONDENSATE LINES SHALL BE INSULATED TO PREVENT SWEATING. 8. THE LOCATION OF CONTROL PANELS AND SENSORS INDICATED ON THIS DRAWING CAN BE MODIFIEDwith THE SPECIFIC LOCATIONS AND WIRING DETAILS WILL BE DETERMINED DURING THE CONTROL SYSTEM DESIGN AND INSTALLATION. 9. THE HVAC SYSTEM DESIGN CONSIDER ENERGY EFFICIENCY, INDOOR AIR QUALITY, OCCUPANT COMFORT, AND NOISE CONTROL, FOLLOWING APPLICABLE GUIDELINES AND REGULATIONS. 10. COORDINATION WITH OTHER TREADS HAS BEEN DONE ON A DESIGN LEVEL. THIS DRAWING SHALL BE READ TOGETHER WITH THE AR, EL AND SN DESIGN DRAWINGS TO ENSURE PROPER INSTALLATION AND INTEGRATION OF THE HVAC SYSTEMS. 11. THE HVAC CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS AND LICENSES, AND FOR SCHEDULING AND COORDINATING WITH THE LOCAL BUILDING DEPARTMENT AND UTILITY PROVIDERS TO ENSURE A TIMELY AND COMPLIANT INSTALLATION. 12. ALL DUCTWORK PENETRATIONS THROUGH WALLS, FLOORS, OR CEILINGS SHALL BE PROPERLY SEALED AND FIRE-STOPPED USING APPROVED METHODS AND MATERIALS TO MAINTAIN THE INTEGRITY OF THE BUILDING'S FIRE-RESISTANCE RATINGS. 13. HVAC EQUIPMENT SHALL BE INSTALLED LEVEL AND PLUMB, AND IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND RECOMMENDATIONS. PROVIDE ADEQUATE CLEARANCES AROUND EQUIPMENT FOR PROPER AIRFLOW, SERVICE ACCESS, AND CODE COMPLIANCE. 14. ALL HVAC EQUIPMENT AND COMPONENTS, INCLUDING THERMOSTATS, DAMPERS, AND ACCESS PANELS, SHALL BE LOCATED IN ACCESSIBLE AREAS FOR EASY SERVICING AND MAINTENANCE. PROVIDE ADEQUATE SPACE AROUND EQUIPMENT FOR PROPER AIRFLOW AND SERVICE ACCESS. 15. THE HVAC SYSTEM SHALL BE BALANCED AND ADJUSTED TO ENSURE PROPER AIRFLOW, TEMPERATURE DISTRIBUTION, AND SYSTEM PERFORMANCE THROUGHOUT THE RESIDENCE. PROVIDE A WRITTEN REPORT DOCUMENTING THE FINAL SYSTEM BALANCE. 16. ANY DEVIATIONS OR MODIFICATIONS TO THE HVAC SYSTEM DESIGN SHALL BE REVIEWED AND APPROVED BY THE RESPONSIBLE DESIGN PROFESSIONALS AND COMMUNICATED TO ALL RELEVANT PARTIES INVOLVED IN THE CONSTRUCTION PROCESS. 17. FOR ANY INQUIRIES OR CLARIFICATIONS REGARDING THE HVAC SYSTEM DESIGN, PLEASE CONSULT THE RESPONSIBLE DESIGN PROFESSIONALS OR THE PROJECT MANAGEMENT TEAM.

EXHAUST FAN

10"x10" SUPPLY DIFFUSER 78 CFM 5' - 10"

4' - 1 1/2"

1' - 0"

5' - 6"

4 1/12'"- 9 1/2" 8" 2' - 5 1/2"6 1/2" 3' - 11 1/2"

1' - 0"

10"x10"

4"x4"

SUPPLY DIFFUSER 78 CFM

SUPPLY DIFFUSER 17 CFM

AA, Ethiopia Info@housedocs.store www.housedocs.store

RECTANGULAR TEE

RECTANGULAR TEE

BEDROOM #1

8"x10"

8"x10"

10"x10"

12"x10"

TRANSITION

RECTANGULAR TEE

2' - 10"

1' - 8"7 1/2"

12"x12"

RETURN DIFFUSER 578 CFM

14"x10"

5"ø

9"ø

12"ø

KITCHEN

1 M102

6"ø

KEY PLAN

NO.

DESCRIPTION

DATE

6"x6"

LIVING ROOM

SUPPLY DIFFUSER 41 CFM

10"x10"

SUPPLY DIFFUSER 294 CFM

6"x6"

EXHAUST FAN

SUPPLY DIFFUSER 70 CFM

NOTE:

4' - 1 1/2"

1' - 0"

13' - 1 1/2"

1' - 0" 2' - 6 1/2"

2' - 1" 9" 2' - 3"

ENTRY

SYMBOLS

VAINED ELBOW; TYPICAL AT ALL SQUARE AND RECTANGULAR ELBOWS

SUPPLY DIFFUSER

LEGEND:

VAINED ELBOW; SHORT RADIUS

STANDARD RADIUS ELBOW

RETURN DIFFUSER

2 M102

1/4" = 1'-0" 1 HVAC Plan

Supply DUCT

AIR TERMINAL SCHEDULE

REFRIGERANT LINE SCHEDULE

CATAGORY

DESCRIPTION

Count

CATAGORY

DESCRIPTION

DIAMETER

LENGTH

RETURN DUCT

EXHAUST DIFFUSER

RETURN DIFFUSER SUPPLY DIFFUSER SUPPLY DIFFUSER SUPPLY DIFFUSER SUPPLY DIFFUSER Grand total: 7

RETURN DIFFUSER: 18 x 18 Face 12 x 12 Connection SUPPLY DIFFUSER: 8 x 8 Face 4 x 4 Connection SUPPLY DIFFUSER: 12 x 12 Face 6 x 6 Connection SUPPLY DIFFUSER: 12 x 12 Face 8 x 8 Connection SUPPLY DIFFUSER: 12 x 12 Face 6 x 6 Connection

1 1 1 3 1 7

Pipe Types Pipe Types Pipe Types

Copper Copper Copper

1/4" 1/2" 3/4"

0' - 4 13/32" 8' - 6 29/32" 8' - 3 15/16"

PROJECT

LOOKOUT NG

RETURN DUCT

SIDEWALL SUPPLY DIFFUSER

REFRIGERANT LINE FITTING SCHEDULE

MECHANICAL EQUIPMENT SCHEDULE

CATAGORY

DESCRIPTION

Count

FLEXIBLE CONNECTION ELEVATION INCLINE - RISE; IN DIRECTION OF FLOW ELEVATION INCLINE - DROP; IN DIRECTION OF FLOW

CATAGORY

DESCRIPTION

COUNT

RETURN DUCT

FC

Elbow - Generic Elbow - Generic

Elbow - Generic: Standard 7

Condenser Exhaust Fan Heat Pump

CONDENSER FOR VPAC - AIR COOLED - 3-7.5 TONS: 3 Tons

1 2

DRAWING NAME

Elbow - Generic: Standard/HVAC

3

EXHAUST FAN: 75 CFM

R

HVAC PLAN

WSHP - VERTICAL - HIGH EFFICIENCY - 2-5 TONS - LEFT RETURN - TOP DISCHARGE: 3 Tons 1

Transition - Generic

Transition - Generic: Standard 4

RETURN DUCT

D

DUCT FITTING SCHEDULE

DUCT ACCESSORY SCHEDULE

CATAGORY

DESCRIPTION

COUNT

RETURN DUCT

CATAGORY

DESCRIPTION

COUNT

CONNECT NEW DUCT TO EXISTING DUCT

E

N

RECTANGULAR ELBOW- RADIUS 1.5 W

2

DUCT HANGER

RECTANGULAR DUCT HANGER

3 4

TRANSITION

45 DEGREE 45 DEGREE 45 Degree STANDARD STANDARD

15

Owner 15_0001

DATE: PROJECT NUMBER: DESIGNED BY: CLIENT NAME:

ROOF VENT

3'' DIAMETER

TRANSITION_ANGLE

5 2 8 5

Round Transition - Angle

ABBREVIATIONS

RECTANGULAR ELBOW RECTANGULAR TEE

8/8/2024 6:41:41 AM

DUCT SCHEDULE

Designer Author Checker

AC ACC ACCU AHU

AIR CONDITIONING UNIT AIR COOLED CONDENSER AIR COOLED CONDENSING UNIT AIR HANDLING UNIT COOLING COIL CEILING DIFFUSER Cubic Feet Per Minute

IV

INLET VANES

E/A EF ET EX F. C

EXHAUST AIR EXHAUST FAN EXPANSION TANK EXISTIN G FLEXIBLE CONNECTION FAN COIL UNIT FLOOR HEATING COIL

CATAGORY

DESCRIPTION

LENGTH SIZE COUNT

CHECKED BY: DRAWN BY:

MECHANICAL ROOM MAXIMU M MINIMU M RETURN AIR RECIPROCATING CHILLER UNIT RETURN FAN SUPPLY AIR SMOKE CONTROL DAMPER STATIC PRESSURE

ME R MAX .MIN R. /A RCU RF S/A SCD SP

FLEX DUCT SCHEDULE

Rectangular Duct Rectangular Duct: Radius Elbows / Tees 1' - 0 3/4" Rectangular Duct Rectangular Duct: Radius Elbows / Tees 0' - 1" Rectangular Duct Rectangular Duct: Radius Elbows / Tees 12' - 5 3/4" Rectangular Duct Rectangular Duct: Radius Elbows / Tees 1' - 7 1/4" Rectangular Duct Rectangular Duct: Radius Elbows / Tees 6' - 8 1/2" Rectangular Duct Rectangular Duct: Radius Elbows / Tees 0' - 4" Rectangular Duct Rectangular Duct: Radius Elbows / Tees 2' - 9 1/2" Rectangular Duct Rectangular Duct: Radius Elbows / Tees 22' - 7 1/2"

4"x4"

1 1 2

DESCRIPTION DESCRIPTION

LENGTH

DIAMETER COUNT

6"x10" 8"x10"

CC CD CFM

10"x10" 2 10"x14" 1 10"x18" 1 12"x10" 1 14"x10" 6

Flex Duct Round FLEX-ROUND Flex Duct Round FLEX-ROUND Flex Duct Round FLEX-ROUND Flex Duct Round FLEX-ROUND Flex Duct Round FLEX-ROUND Flex Duct Round FLEX-ROUND

18' - 5 5/8" 10' - 5 3/32" 23' - 2 7/32" 11' - 11 9/16" 22' - 9 27/32" 87' - 1 1/16" 0' - 2 3/4"

4" 5" 6" 9"

4 1 3 1 1 2

FCU FLR.

M101

HC HE HV

CEILING REGISTER CONDENSING UNIT COLD WATER

CR CU CW

10" 12"

AIR TO AIR HEAT EXCHANGER HEATING AND VENTILATING UNIT

Round Duct

Round Duct: Tees

10' - 3 1/4"

6"ø

1

Grand total: 12

SCALE:

As indicated

© [2024] [FrameUpNow] [HouseDocs]. All rights reserved