Lookout No Garage

CONDUIT COLOR SCHEME

INTERMIDIATE METAL CONDUIT ELECTRICAL METAL TUBING CONDUIT

Tuscon,AZ, USA 888-864-0184 inquire@frameupnow.com www.frameupnow.com

NOTES: CONDUIT, CABLE AND WIRING

AA, Ethiopia Info@housedocs.store www.housedocs.store

1. 2. 3. 4. 5. 6. 7.

USE METALIC CONDUITS (IMC) FOR CABLES RUNNING UNDER CONCRETE SLABS. USE IMC FOR CIRCUITS WITH HIGH VOLTAGE APPLIANCES (240 VOLTS AND ABOVE) FOR CIRCUITS WITH 120 VOLTS CONSIDER USING EMT OR PVC CONDUITS IF NEEDED. FOR LOW VOLTAGE APPLICATIONS UP TO 50 VOLTS CONSIDER USING NON METALIC CONDUITS. ALL CONDUITS TO BE USED IN THE PROJECT MUST CONFORM TO THE LATEST NATIONAL ELECTRICAL CODE (NEC), 2015. ALL WIRING AND CABLES TO BE USED IN THE PROJECT MUST ALSO CONFORM TO THE LATEST NATIONAL ELECTRICAL CODE (NEC), 2015. ALL CABLES AND WIRES USED SHOULD BE RATED FOR THEIR RESPECTIVE LOADING AND SHOULD BE GAUGED AND CONFORM TO THE NEC.

KEY PLAN

3

1

Conduit Schedule

3

Ref

Type

Length

Size

NO.

DESCRIPTION

DATE

Electrical Metallic Tubing (EMT) Intermidate Metal Conduit (IMC)

817' - 7 11/32"

1/2"ø

147' - 6 3/16"

1/2"ø

NOTE:

LEGEND:

#1/4 pullbox

3 E103

PROJECT

LOOKOUT_NG_350

GFCI Kitchen

GFCI Kitchen

Lighting and Appliance Panelboard- 240v

DRAWING NAME

POWER

3/8" = 1'-0" 2 POWER PLAN

#1/4 pullbox

#1/4 pullbox

#1/4 pullbox

1/2"ø

1/2"ø

1/2"ø

1/2"ø

Owner 0021_15

DATE: PROJECT NUMBER: DESIGNED BY: CLIENT NAME:

7/30/2024 3:50:10 AM

GFCI WASHER

Designer Author Checker

CHECKED BY: DRAWN BY:

Standard Living RM

Standard Living RM

Standard bed room

Standard bed room

1/2"ø

1/2"ø

1/2"ø

?

E103

1 3D-KITCHEN

1/4" = 1'-0" 3 SECTION

SCALE:

As indicated

© [2024] [FrameUpNow] [HouseDocs]. All rights reserved