CONDUIT COLOR SCHEME
INTERMIDIATE METAL CONDUIT ELECTRICAL METAL TUBING CONDUIT
Tuscon,AZ, USA 888-864-0184 inquire@frameupnow.com www.frameupnow.com
NOTES: CONDUIT, CABLE AND WIRING
AA, Ethiopia Info@housedocs.store www.housedocs.store
1. 2. 3. 4. 5. 6. 7.
USE METALIC CONDUITS (IMC) FOR CABLES RUNNING UNDER CONCRETE SLABS. USE IMC FOR CIRCUITS WITH HIGH VOLTAGE APPLIANCES (240 VOLTS AND ABOVE) FOR CIRCUITS WITH 120 VOLTS CONSIDER USING EMT OR PVC CONDUITS IF NEEDED. FOR LOW VOLTAGE APPLICATIONS UP TO 50 VOLTS CONSIDER USING NON METALIC CONDUITS. ALL CONDUITS TO BE USED IN THE PROJECT MUST CONFORM TO THE LATEST NATIONAL ELECTRICAL CODE (NEC), 2015. ALL WIRING AND CABLES TO BE USED IN THE PROJECT MUST ALSO CONFORM TO THE LATEST NATIONAL ELECTRICAL CODE (NEC), 2015. ALL CABLES AND WIRES USED SHOULD BE RATED FOR THEIR RESPECTIVE LOADING AND SHOULD BE GAUGED AND CONFORM TO THE NEC.
KEY PLAN
3
1
Conduit Schedule
3
Ref
Type
Length
Size
NO.
DESCRIPTION
DATE
Electrical Metallic Tubing (EMT) Intermidate Metal Conduit (IMC)
817' - 7 11/32"
1/2"ø
147' - 6 3/16"
1/2"ø
NOTE:
LEGEND:
#1/4 pullbox
3 E103
PROJECT
LOOKOUT_NG_350
GFCI Kitchen
GFCI Kitchen
Lighting and Appliance Panelboard- 240v
DRAWING NAME
POWER
3/8" = 1'-0" 2 POWER PLAN
#1/4 pullbox
#1/4 pullbox
#1/4 pullbox
1/2"ø
1/2"ø
1/2"ø
1/2"ø
Owner 0021_15
DATE: PROJECT NUMBER: DESIGNED BY: CLIENT NAME:
7/30/2024 3:50:10 AM
GFCI WASHER
Designer Author Checker
CHECKED BY: DRAWN BY:
Standard Living RM
Standard Living RM
Standard bed room
Standard bed room
1/2"ø
1/2"ø
1/2"ø
?
E103
1 3D-KITCHEN
1/4" = 1'-0" 3 SECTION
SCALE:
As indicated
© [2024] [FrameUpNow] [HouseDocs]. All rights reserved