CONDUIT COLOR SCHEME
INTERMIDIATE METAL CONDUIT ELECTRICAL METAL TUBING CONDUIT
Tuscon,AZ, USA 888-864-0184 inquire@frameupnow.com www.frameupnow.com
NOTES: LIGHT
AA, Ethiopia Info@housedocs.store www.housedocs.store
1. 2.
LIGHT FIXTURES AND LUMINARIES SHALL CONFORM TO THE NEC, THE IRC AND LOCAL SAFETY & BUILDING CODE. ALL LIGHTING FIXTURES SHOULD CONFORM TO THE DESIGN ELECTRICAL LOAD AND SHALL BE PROPERLY WIRED AND MOUNTED BY QUALIFIED ELECTRICIAN FOLLOWING MANUFACTURERS SPECIFICATIONS. CEILING FANS AND FANS WITH LIGHT WITH WEIGHT EXCEEDING 35 LBS SHOULD BE PROVIDED WITH STRUCTURAL BACKING FOR SUPPORT AND SHALL BE FIXED AS PER MANUFACTURERS SPECIFICATIONS. EXTERIOR LIGHTS SHALL CONFORM TO LOCAL BUILDING CODE AND GUIDELINES.
KEY PLAN
3.
4.
8' - 10"
4' - 11"
4' - 11"
8' - 7"
NOTES: SWITCH JUNCTION BOX
Ref
NO.
DESCRIPTION
DATE
1. 2. 3. THE MINIMUM SIZE OF JUCTION BOX TO BE USED IS 2''X4''X(1.5'' OR 3.5'' DEEP) THIS ARE TO BE USED FOR SINGLE GANG SWITCH OR OUTLETS. FOR DOUBLE GANG (2 GANG) OUTLETS AND SWITCHS THE MINIMUM SIZE OF THE JUCTION BOX TO BE PROVIDED SHALL NOT BE LESS THAN 4''X4"X(1.5'' OR 3.5'' DEEP) FOR THREE GANG (3 GANG) OUTLETS AND SWITCHS THE MINIMUM SIZE OF THE JUCTION BOX SHALL NOT BE LESS THAN 6''X4"X(1.5'' OR 3.5'' DEEP).
10' - 1"
6' - 8"
Conduit Fitting Schedule(junction box) Family Count
NOTE:
Description
Conduit Junction Box - Cross - Aluminum Conduit Junction Box - Tee - PVC
1
4
T way
pullbox1
22
#1/4 pullbox
Electrical Fixture Schedule (SWITCH BOX) Type Count
LEGEND:
Double Gang Switch Box Single Gang Switch Box Triple Gang Switch Box
3 5 3
2' - 1 15/32"
14' - 9 1/4"
7' - 8 9/16"
2' - 8 7/32"
Lighting Device
Type
Count
Fan switch Single Pole Three Way
5 7 8
PROJECT
3 E103
LOOKOUT_NG_350
Lighting Fixture
Lighting Fixture Type
Voltage
Electrical Load
Count
Ceiling Light - Flat Round
120 V/1-60 VA
200 A, 120 V/240 V, Single Phase, 3 Wires 200 A, 120 V/240 V, Single Phase, 3 Wires 200 A, 120 V/240 V, Single Phase, 3 Wires 200 A, 120 V/240 V, Single Phase, 3 Wires 200 A, 120 V/240 V, Single Phase, 3 Wires 200 A, 120 V/240 V, Single Phase, 3 Wires
10
Downlight - Round - LED 120 V/1-15 VA
3
DRAWING NAME
DIMENSION PLAN FOR LIGHT FIXTURES
Electrical_Lights_Fan- Light1 Floor Lamp - Standup Pendant Light - Linear - 2 Lamp
120 V/1-100 VA- 120 V/1-100 VA
3
1 1
120 V/1-64 VA
9' - 4"
9' - 4"
9' - 4"
Standalone Linear 120 V/1-100 VA
1
WATERPROOF RECESSED CEILING LIGHT
120 V/1-15 VA
1
Owner 0021_15
DATE: PROJECT NUMBER: DESIGNED BY: CLIENT NAME:
7/30/2024 3:50:13 AM
3/8" = 1'-0" 1 DIMENSION FOR LIGHT FIXTURES
Designer Author Checker
CHECKED BY: DRAWN BY:
E104
SCALE:
As indicated
© [2024] [FrameUpNow] [HouseDocs]. All rights reserved
Made with FlippingBook Online newsletter maker