Lookout No Garage

CONDUIT COLOR SCHEME

INTERMIDIATE METAL CONDUIT ELECTRICAL METAL TUBING CONDUIT

Tuscon,AZ, USA 888-864-0184 inquire@frameupnow.com www.frameupnow.com

NOTES;

1. 2. 3. 4. VERIFY EQUIPMENT PLUG CONFIGURATION BEFORE PURCHASING RECEPTACLES FOR ALL EQUIPMENT. COORDINATE EXACT LOCATION OF LIGHT FIXTURES, WALL SWITCHES, RECEPTACLES AND OTHER DEVICES WITH ARCHITECTURAL DRAWINGS. USE METALLIC JUNCTION BOX WITH THE GFCI RECEPTACLES, WITH HIGHT VOLTAGE.

5' - 0 15/16"

16' - 4"

5' - 10 17/32"

AA, Ethiopia Info@housedocs.store www.housedocs.store

KEY PLAN

Electrical Fixture Schedule (Receptacle) Type Count

AIR HANDLER CONDENSER

1 1 1 1 4 4 1 1 1 2 1

4' - 7"

17' - 3"

5' - 5"

DRYER

GFCI BATH ROOM GFCI Kitchen GFCI OUT DOOR GFCI WASHER

NO.

DESCRIPTION

DATE

3' - 0"

3' - 11"

Ref

7' - 1"

8' - 2"

3' - 7"

RANGE

1' - 8"

REFRIGERATOR

Standard bed room Standard Living RM

12

water heater

NOTE:

Electrical Outlet Schedule

Type

Circuit Number Electrical Data Electrical Data

Count

<varies>

11

Standard bed room

1

120 V/1-1500 VA

5

LEGEND:

GFCI OUT DOOR 2 REFRIGERATOR 3

120 V/1-180 VA 120 V/1-1500 VA 120 V/1-1500 VA 240 V/2-5000 VA 120 V/1-1500 VA 240 V/2-5000 VA 240 V/2-5000 VA 120 V/1-180 VA 120 V/1-180 VA 240 V/2-1500 VA 240 V/2-5000 VA 120 V/1-1500 VA

4 1 4 1 1 1 1 4 1 1 1 5

Standard bed room

4

RANGE

5,7

GFCI WASHER 9

DRYER

10,12

water heater 11,13 GFCI Kitchen 14 GFCI BATH ROOM 15 CONDENSER 17,19 AIR HANDLER 18,20

5' - 10"

7' - 8"

8' - 7"

5' - 3"

<varies>

<unnamed>

3' - 8"

10' - 4"

14' - 5"

PROJECT

LOOKOUT_NG_350

3 E103

DRAWING NAME

DIMENSION PLAN FOR FITTINGS

Owner 0021_15

DATE: PROJECT NUMBER: DESIGNED BY: CLIENT NAME:

3/8" = 1'-0" 1 DIMENSION FOR FITTINGS

7/30/2024 3:50:17 AM

Designer Author Checker

CHECKED BY: DRAWN BY:

E105

SCALE:

As indicated

© [2024] [FrameUpNow] [HouseDocs]. All rights reserved