Lookout No Garage

WATER FIXTURE UNIT SCHEDULE

PLUMBING SCHEDULE

SHEET LIST

PIPe Color SCHEME

DOMESTIC COLD WATER DOMESTIC HOT WATER SANITARY VENT

Fixture

QTY.

Unit Value

TOTAL

FIXTURE

Trap

Waste

Vent

C.W

H.W

Sheet Number

Sheet Name

Tuscon,AZ, USA 888-864-0184 inquire@frameupnow.com www.frameupnow.com

BATH TUB HOSE BIB

1 3 1 1 1 1

1.4 2.5 1.4 0.7 2.2

1.4 7.5 1.4 0.7 2.2

BATH TUB

1-1/2"

2"

1-1/2"

1/2" N/A 1/2" 1/2" 1/2" 1/2" 1/2"

1/2" N/A 1/2" 1/2" 1/2" 1/2" 1/2"

P101 P102 P103

Notes and Schedules WATER SUPPLY SYSTEM

SANITARY SEWER STORM DRAINAGE

DRYER

N/A

N/A

N/A

KITCHEN SINK Vanity Sink Water Closet Water Heater

KITCHEN SINK Vanity Sink

1-1/2" 1-1/2"

2" 2" 2" 3"

1-1/2" 1-1/2" 1-1/2"

SEWAGE SYSTEM

WASHER

2" 3"

Water Closet Water Heater

2"

PLUMBING NOTES

N/A

N/A

N/A

AA, Ethiopia Info@housedocs.store www.housedocs.store

WASTE FIXTURE UNIT SCHEDULE

1.

The plumbing system is designed to meet the building's domestic water supply, sanitary drainage, and storm drainage requirements, as per project specifications and applicable codes. The system installation shall comply with the latest International Plumbing Code (IPC), International Residential Code (IRC), and all other relevant local, state, and national regulations. ALL PLUMBING WORK SHALL COMPLY WITH THE LATEST EDITION OF THE INTERNATIONAL PLUMBING CODE (IPC) AND THE LOCAL PLUMBING CODE. PLUMBING SYSTEMS SHALL BE TESTED AND INSPECTED IN ACCORDANCE WITH THE LOCAL PLUMBING CODE REQUIREMENTS. PLUMBING FIXTURES SHALL BE INSTALLED WITH THE APPROPRIATE TRIM, FITTINGS, AND ACCESSORIES, AS RECOMMENDED BY THE MANUFACTURER. PIPING SHALL BE PROPERLY SUPPORTED AND SECURED TO PREVENT SAGGING, MOVEMENT, AND VIBRATION. SHUT-OFF VALVES SHALL BE PROVIDED AT ALL BRANCH CONNECTIONS AND AT THE INLET AND OUTLET OF EACH PIECE OF EQUIPMENT. BACKFLOW PREVENTION DEVICES SHALL BE INSTALLED AS REQUIRED BY THE LOCAL PLUMBING CODE TO PROTECT THE POTABLE WATER SYSTEM. PLUMBING FIXTURES AND EQUIPMENT SHALL BE ACCESSIBLE FOR MAINTENANCE AND SERVICING. EXPOSED PLUMBING PIPING AND FIXTURES SHALL BE INSULATED TO PREVENT CONDENSATION AND ENERGY LOSS. DEAD ENDS IN THE DRAINAGE SYSTEM MUST BE AVOIDED, EXCEPT WHERE NECESSARY TO INSTALL A CLEANOUT IN AN ACCESSIBLE LOCATION, AND MUST HAVE A VENTED CONNECTION TO THE OUTSIDE ATMOSPHERE. THE VERTICAL DEFLECTION OF PVC PIPE MUST NOT EXCEED 5%, AND NO DEFLECTION IS PERMITTED FOR IRON PIPE. WORK MUST BE PROPERLY COORDINATED WITH OTHER TRADES TO AVOID CONFLICTS, REFERRING TO THE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR INFORMATION REGARDING CEILING ELEVATIONS, SPACE CLEARANCES, WALL AND PARTITION LOCATIONS, ETC. ALL FIXTURES SHALL HAVE ACCESSIBLE STOPS. DOMESTIC WATER PIPING SHALL BE PEX, AND PVC PIPING IS NOT ACCEPTABLE FOR INTERIOR USE. VENT TERMINATIONS SHALL BE LOCATED AT LEAST 10 FEET FROM OR 3 FEET ABOVE ANY OPERABLE WINDOW, DOOR OPENING, AIR INTAKE, OR VENT SHAFT, AND AT LEAST 3 FEET IN EVERY DIRECTION FROM ANY LOT LINE, ALLEY, OR STREET. PIPE AND FITTINGS UTILIZED IN THE WATER SUPPLY SYSTEM SHALL HAVE A MAXIMUM OF 8 PERCENT LEAD. ACRYLONITRILE BUTADIENE STYRENE (ABS) SHALL BE USED FOR THE SEWERAGE AND VENTILATION SYSTEM. CROSS-LINKED POLYETHYLENE (PEX) SHALL BE USED FOR THE WATER SUPPLY SYSTEM. POLYVINYL CHLORIDE (PVC) SHALL BE USED FOR THE RAIN WATER SYSTEM. THE MIMIMUM WATER SUPPLY DEPTH UNDER FLOOR FINISH SHOUD BE 1/2". ANY PIPE INSTALLED UNDERGROUND MUST HAVE AT LEAST 12 INCHES OF CLEARANCE BETWEEN THE OUTSIDE OF THE PIPE AND ANY OTHER UNDERGROUND STRUCTURE. THE MINIMUM CLEARANCE BETWEEN COLD AND HOT WATER LINES IN RESIDENTIAL HOMES MAINTAIN A MINIMUM DISTANCE OF 6 INCHES. HORIZONTAL SEPARATION BETWEEN WATER AND SEWER LINES : A MINIMUM OF 12 INCHES BETWEEN POTABLE WATER SUPPLY LINES (COLD AND HOT WATER) AND SANITARY SEWER LINES.

Fixture

QTY.

DFU VALUE

DFU TOTAL

2.

BATH TUB

1 1 1 1 1

2 2 1 3

2 2 1 3

KEY PLAN

KITCHEN SINK Vanity Sink Water Closet Water Heater

3. 4. 5. 6. 7. 8. 9.

-

FITTING SCHEDULE

FITTING

Size

QTY

Domestic Cold Water PEX 90 Deg Elbow

1/2"ø-1/2"ø 3/4"ø-3/4"ø

15

PEX 90 Deg Elbow PEX Tee Elbow PEX Tee Elbow

1 5 3 6

NO.

DESCRIPTION

DATE

1/2"ø-1/2"ø-1/2"ø 3/4"ø-3/4"ø-3/4"ø

10. 11.

PEX Transition Elbow

3/4"ø-1/2"ø

Domestic Hot Water PEX 90 Deg Elbow PEX 90 Deg Elbow

1/2"ø-1/2"ø 1/2"ø-1/2"ø

3 8 3

12. 13.

PEX Tee Elbow

1/2"ø-1/2"ø-1/2"ø

Rain Water PVC Sch. 80 90 Deg Bend Elbow Sewage ABS 90 Deg Bend Elbow ABS 90 Deg Bend Elbow ABS 90 Deg Bend Elbow ABS CLOSET BEND REDUCER

2"ø-2"ø

23

14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24.

NOTE:

1 1/2"ø-1 1/2"ø

1 4 1 1 2 3 3 1 1 3 1 1 1 2

2"ø-2"ø 3"ø-3"ø 4"ø-3"ø

ABS Reducer Elbow ABS Reducer Elbow

2"ø-1 1/2"ø

3"ø-2"ø

ABS Tee Elbow ABS Tee Elbow

1 1/2"ø-1 1/2"ø-1 1/2"ø

3"ø-3"ø-3"ø 2"ø-2"ø-2"ø

ABS Tee Reducer Elbow

ABS Trap P ABS Trap P

1 1/2"ø-1 1/2"ø

LEGEND:

2"ø-2"ø

ABS Wye 45 Deg

2"ø-2"ø-2"ø

ABS Wye Combination ABS Wye Combination

3"ø-3"ø-1 1/2"ø

3"ø-3"ø-3"ø

Undefined Closet Flange

4"ø-3"ø

1

Vent ABS 90 Deg Bend Elbow ABS 90 Deg Bend Elbow ABS Tee Reducer Elbow ABS Tee Reducer Elbow

1 1/2"ø-1 1/2"ø

1 1 1 1 1 1

2"ø-2"ø

2"ø-1 1/2"ø-1 1/2"ø

ABBREVIATIONS

PLUMBING LEGEND

2"ø-2"ø-1 1/2"ø

ABS Vent Cap ABS Vent Cap

1 1/2"ø

Ø ABS ABV AD AFF ALT BFF BLW CO CW D DFU DIA DN FCO FD FL FS FT HB HW IN MIN NO NTS PEX PLBG RM RW SF V VTR W WCO WSFU PVC QTY RD RED

Diameter ACRYLONITRILE BUTADIENE STYRENE ABOVE AREA DRAIN ABOVE FINISHED FLOOR ALTERNATE BELOW FINISHED FLOOR BELOW CLEAN OUT COLD WATER DEGREE Dranage FIXTURE UNIT DIAMETER DOWN FLOOR CLEAN OUT FLOOR DRAIN FLOOR

2"ø

Cap

Bend 45 Deg

PROJECT

FIXTURE SCHEDULE

Bend 90 Deg

FIXTURE

QTY

Description

Lookout_NG_350

Tee Reducing

BATH TUB

1 1 1 1 1 1 1

Tee

DRYER

KITCHEN SINK Vanity Sink

Clean Two-Way

WASHER

Water Closet Water Heater

DRAWING NAME

Wye 45 Deg

Notes and Schedules

Wye 45 Deg Double

FLOOR SINK FOOT/FEET HOSE BIB HOT WATER INCH

ACCESSORIES & Fitting SCHEDULE

Family

Count

Descriptions

Wye Combination

Hanging pipes clamp

18

MINIMUM NUMBER NOT TO SCALE CROSS-LINKED POLYETHYLENE PLUMBING POLYVINYL CHLORIDE Quantity ROOF DRAIN REDUCER ROOM RAIN WATER SQUARE FOOT VENT VENT THROUGH ROOF WASTE WALL CLEAN OUT WATER SUPPLY FIXTURE UNIT

HOSE BIB

3 1 4 2

P-Trap

Owner 0021_15

DATE: PROJECT NUMBER: DESIGNED BY: CLIENT NAME:

LAUNDRY SWEAT CONNECTOR

Shutoff Valve Shutoff Valve

9/7/2024 3:14:34 PM

Designer Author Checker

CHECKED BY: DRAWN BY:

PIPE SCHEDULE

Material

Diameter

Length

Acrylonitrile Butadiene Styrene (ABS) Acrylonitrile Butadiene Styrene (ABS) Acrylonitrile Butadiene Styrene (ABS) Cross-linked polyethylene (PEX) Cross-linked polyethylene (PEX)

1 1/2"

25 ft 37 ft 33 ft

2" 3"

P101

1/2" 3/4"

125 ft 21 ft 74 ft

Polyvinyl Chloride - Rigid

2"

SCALE:

1/2" = 1'-0"

Made with FlippingBook Online newsletter maker