ENDOTRACHEAL TUBES
9
• Silicone Material - MRI Compatible • Reusable • Ethylene Oxide Sterilization Recommended • Low Pressure, High Volume Cuff
Cuffed
Atomizer/Throat Sprayer
DESCRIPTION
ITEM # ETC20
PRICE $42.00
Deliver topical anesthetic to the nose, throat, hypopharynx, vocal cords, larynx and trachea prior to airway manipulation such as intubation, endoscopy, rhinoscopy and soft palate exam. The benefit is a reduced gag and sensation, reduced pulse and blood pressure response to intubation. • Atomize medication into a fine mist of particles 50-80 microns. • 15Fr (4.7mm) tip x 6.5 inch (15cm) malleable, conformable tube for targeted deposition of medication. • 5cc syringe is recommended for accurate dosing and proper pressure. • Priming volume is 0.2ml. • Use a 3ml syringe for a minimum forecast distance of 100mm upon exiting the sprayer tip under 25Kpa pressure to form an area of diameter of no less than 70mm. ITEM #5380 $4.75
2mm ID, 4.0mmOD - 12Fr x 14cm (5.5in)
Reinforced Endotracheal Tubes with Malleable Stylet • R einforced with embedded wire coils to provide safe, NON-KINKING airway regardless of patient position. • Constructed of medical grade, non-toxic PVC material allowing for thinner walls. • Malleable stylet included for increased rigidity and variable shape. • Latex free. • High volume, low pressure cuff. • Radiopaque. • Fully transparent. • Atraumatic bevel tip with lateral Murphy eye. • 15mm connector included. DESCRIPTION ITEM # PRICE 2.5mm ID, 4.5mmOD - 13Fr x 19.5cm (7.6in) ETC25R $18.00 3.0mm ID, 5.0mmOD - 15Fr x 20.5cm (8.1in) ETC30R $18.00 3.5mm ID, 5.7mmOD - 17Fr x 22cm (8.7in) ETC35R $18.00
“The device makes endoscopy work within the nasal cavity, soft palate, larynx and pharnyx much easier by distributing a fine mist of lidocaine or lidocaine/phenylephrine.” “We also use the device to distribute same mixture in hard to reach surgical areas such as otic canals, wound flaps, urogenital tracts, and to atomize topical local anesthetics and hemostatic agents to bleeding tumors and derm biopsy sites.”
Andrea Looney, DVM, DACVAA, DACVSMR Anesthesia Services, IVG Hospitals, Woburn, MA
Double Swivel Tracheal Tube Connector with Capped Port, 15mm
N E W
Designed to facilitate introduction of fiber optic bronchoscope during mechanical ventilation. • Silicone port with cap allows easy passage of fiber optic scope for bronchoscopy. • Allows for suction catheter without disconnecting from ventilator. • Maintains seal around scope during bronchoscopy procedure. Seal accepts bronchoscope diameters from 3.4 to 5.9mm. • 360º Double Swivel Feature: Both the male and female 15mm connectors allow greater patient maneuverability between endotracheal tube and anesthesia circuit.
Port for Bronchoscope
Connect to Anesthesia Circuit
Connect to Endotracheal Tube
ITEM #SC15MM
$7.00
www.milaint.com
Made with FlippingBook Online newsletter maker