Consumables Digital Catalogue

Browse Shimadzu consumables products easily right from your computer, tablet or phone. Designed to be user friendly, easy-to-navigate contents page with a click, you can promptly and easily source the right product for customer's application. What you can do with our interactive consumables catalog: Option to print specific page(s). Download entire catalogue or specific page(s). URL link for a specific page for you to send to your customer. Bookmark function that allows you to easily access your favorite pages on the eCatalogue. We trust you will find our catalog informative and convenient.

For over 140 years, Shimadzu has continued

to be your trusted partner by providing

leading-edge analytical instruments.

Now we further support your success

through borderless delivery of the high quality

consumable products that solve everyday

challenges. All this is for the pursuit of our

corporate philosophy “Contributing to Society

through Science and Technology”.

Table of Contents HPLC COLUMNS

METAL FREE COLUMNS Scepter Series............................................................................................A-86 G Series......................................................................................................A-87 Mastro™ Series.........................................................................................A-88

Column Selection Guide.............................................................................A-2 Selection by USP Code................................................................................A-7

CORESHELL COLUMN VELOX SERIES Velox C18...................................................................................................A-10 Velox SP-C18..............................................................................................A-10 Velox Biphenyl..........................................................................................A-12 Velox PFPP.................................................................................................A-12 Velox HILIC................................................................................................A-13 ORGANIC SILICA HYBRID SCEPTER SERIES Scepter C18...............................................................................................A-16 Scepter HD-C18.........................................................................................A-17 Scepter C8.................................................................................................A-18 Scepter PFPP..............................................................................................A-19 Scepter Pheny I.........................................................................................A-20 Scepter Diol-HILIC.....................................................................................A-21 Scepter C4.................................................................................................A-22 ARATA SERIES Arata C18..................................................................................................A-25 Arata Peptide C18.....................................................................................A-26

SFC COLUMNS UC Series....................................................................................................A-90

DEDICATED COLUMNS Cannabis Analysis.....................................................................................A-94 Analysis of Amino Acids...........................................................................A-95 Analysis of Sugar and Organic Acid........................................................A-96 Analysis of Organic Acids.........................................................................A-98 Analysis of Nucleotides, Oligonucleotides and Proteins........................A-99 Intact Amino Acid Analysis....................................................................A-100 ION CHROMATOGRAPHY COLUMNS IC Series...................................................................................................A-101 Ultron PS-80H..........................................................................................A-105 PRETREATMENT COLUMNS MAYI Series.............................................................................................A-106 SPC Series................................................................................................A-108 CHIRAL COLUMNS ULTRON SERIES Ultron ES-OVM........................................................................................A-110 Ultron ES-OVM-C....................................................................................A-110 Ultron ES-OVM-3....................................................................................A-110 Ultron ES-PEPSIN.....................................................................................A-111 Ultron ES-BSA..........................................................................................A-111 Ultron ES-CD...........................................................................................A-112 Ultron ES-PhCD.......................................................................................A-112 LIGAND EXCHANGE COLUMNS ULTRON SERIES Ultron PS-80N..........................................................................................A-113 Ultron PS-80C..........................................................................................A-113 Ultron PS-80P..........................................................................................A-113 Ultron CI..................................................................................................A-114 Ultron CL.................................................................................................A-114 ULTRON SERIES Ultron VX-SIL...........................................................................................A-115 Ultron VX-ODS........................................................................................A-116 Ultron VX-Octyl.......................................................................................A-117 Ultron AF-HILIC-DA.................................................................................A-118 STR-ODS SERIES STR-ODS-II. ..............................................................................................A-119 STR ODS-M..............................................................................................A-120 MOBILE PHASE CLEANER FOR UHPLC/HPLC Ghost Trap DS/DS-HP..............................................................................A-121 GLC Suction Filter 2................................................................................A-122

GENERAL PURPOSE COLUMNS XR-ODS SERIES

XR-ODS......................................................................................................A-28 XR-C8.........................................................................................................A-28 XR-Phenyl..................................................................................................A-28 XR SIL........................................................................................................ A-28 XR-ODS II...................................................................................................A-30 XR-ODS III..................................................................................................A-30 VP SERIES VP-ODS..................................................................................................... A-32 VP-C8........................................................................................................ A-32 VP-Phenyl................................................................................................. A-32

MAqC-ODS ................................................................................................A-36

G SERIES GIST C18................................................................................................... A-38 GIST C18-AQ............................................................................................. A-40 GISS C18.................................................................................................... A-42 GIS C18..................................................................................................... A-44 GIS C18-P.................................................................................................. A-46 GIS RP-Shield............................................................................................ A-48 GWS C18................................................................................................... A-49 GIST C8..................................................................................................... A-50 GIST Phenyl.............................................................................................. A-52 GIST Phenyl-Hexyl.................................................................................... A-54 GIST PFPP...................................................................................................A-56 GIS HILIC....................................................................................................A-58 GIST NH2...................................................................................................A-60 GIST Amide................................................................................................A-62 GIS CN........................................................................................................A-64 Solar C18...................................................................................................A-66 Solar C8.................................................................................................... A-66 FC-ODS.......................................................................................................A-67 PREPARATIVE COLUMNS PREP Series............................................................................................... A-69 G Series..................................................................................................... A-69 UC Series....................................................................................................A-71 Ultron VX Series........................................................................................A-72 STR-ODS Series..........................................................................................A-72

FITTINGS ..................................................................................................A-123

VIALS AND ACCESSORIES VIALS ........................................................................................................... B-2 SOLVENT KITS . .......................................................................................... B-19 SAMPLE PREPARATION ............................................................................. B-21 GC COLUMNS AND ACCESSORIES GC COLUMN CROSS-REFERENCE . .............................................................. C-4 GC CAPILLARY COLUMNS . ......................................................................... C-6 GC PACKED COLUMNS . ............................................................................ C-51 SYRINGES .................................................................................................. C-57 GLASS INSERT . .......................................................................................... C-67 FERRULES . ................................................................................................. C-70 SEPTUMS ................................................................................................... C-72 SPME ARROW ........................................................................................... C-73 SPME FIBER . .............................................................................................. C-74

MIXED-MODE COLUMNS Shimadzu Redual™ Columns...................................................................A-73

BIO LC COLUMNS Scepter C4.................................................................................................A-74 Bio Series...................................................................................................A-76 Arata Peptide C18.....................................................................................A-77 Bio HIC--Butyl............................................................................................A-78 MICROSCALE COLUMNS MC C18......................................................................................................A-79 MC PLONAS Series....................................................................................A-80 Trap Columns............................................................................................A-82 SIZE EXCLUSION CHROMATOGRAPHY COLUMNS GPC Series..................................................................................................A-83 Diol Series..................................................................................................A-85

GAS FLTRATION . ..............................................................................D-1

SPECTRUM CONSUMABLES .................................................... E-1

APPENDIX I..................................................................................................F-1

UHPLC/HPLC Columns and LC Accessories

Column Selection Guide

Selection by Support Materials

Shim-pack XR, VP, MAqC-ODS, G Series, FC-ODS, Velox Series, Arata C18 Shim-pack UC Series Shim-pack Diol Series Shim-pack WAX/WCX Series

Silica Gel Type

Packing Materials

Organic Silica Hybrid

Shim-pack Scepter Series

Shim-pack GPC Series Shim-pack IC Series Shim-pack Amino, SCR, ISA/ISC Series

Polymer Type

Selection by Separation Modes

ODS/C18 (Shim-pack XR, VP, MAqC, G, FC Series, Velox, Scepter) Shim-pack GIST C18-AQ Shim-pack GIS C18-P Shim-pack GIS RP-Shield C8 (Shim-pack XR, VP, G Series) Phenyl (Shim-pack XR, VP, G Series) Shim-pack GIST Phenyl-Hexyl Shim-pack Velox Biphenyl Shim-pack Velox PFPP, Shim-pack Scepter PFPP

Low molecular- weight compounds

Reversed Phase

Shim-pack GIS CN.........................................................................Steroid hormones Shim-pack XR-SIL................................................................................Phospholipids Shim-pack GIST NH2.........................................................Saccharides, tocopherols

Normal Phase

Silica Gel Type

HILIC Mode

Shim-pack GIS HILIC, Velox HILIC, Scepter HILIC.........................Polar compounds

Shim-pack WAX (weakly basic anion exchange)..................Nucleotides, proteins Shim-pack WCX (weakly acidic cation exchange).......................................Proteins

Ion Exchange

Shim-pack Diol Series...................................................................................Proteins Shim-pack Bio Diol Series...........MAb, oligonuclestides, carbonydrates, proteins

Gel Filtration

Shim-pack IC Series.............................................................................Inorganic ions Shim-pack Amino, ISC Series............................................Amino acids, guanidines Shim-pack ISA Series...............................................................................Saccharides Shim-pack Bio IEX..........................Peptides, oligonuclestides, biopharmaceutical, proteins, nucleic acids

Ion Exchange

Polymer Type

Shim-pack SCR-101H, SCR-102H......................................................... Organic acids Shim-pack Fast-OA...............................................................................Organic acids

Ion Exclusion

GPC

Shim-pack GPC Series....................................................... Synthetic high polymers

Pg A-2

Selection by Column Particle Sizes

1.6 µm, 2.2 µm

Shim-pack XR-ODS III, Arata C18

High-Speed Analysis

1.8 µm, 2.7 µm

Shim-pack Velox Series

1.9 µm, 2 µm, 2.2 µm, 3 µm

Analytical Columns

Shim-pack G, XR Series, Scepter Series

Conventional Analysis

Shim-pack VP, MAqC-ODS, G Series, FC-ODS, Arata C18, Velox Series, Scepter Series

≥ 3 µm

HPLC Columns

5 µm, 10 µm

Shim-pack G Series, Scepter Series

Preparative Columns

15 µm

Shim-pack PREP Series

Selection of ODS columns

Shim-pack XR-ODS (Pressure tolerance: 35MPa)..................A-28 Shim-pack XR-ODS II (Pressure tolerance: 60MPa)...............A-30 Shim-pack XR-ODS III (Pressure tolerance: 100MPa)............A-30

With Certificate of Compliance for Validation

Shim-pack Scepter C18 / HD-C18 (pH range: 1 - 12).............A-16 Shim-pack GIST/GIST-HP C18 (pH range: 1 - 10)....................A-38

Wider pH Range

Rapid Separation and Wider pH Range

High-Speed Analysis

Shim-pack GISS/GISS-HP C18 (pH range: 1 - 10)....................A-42

Shim-pack Scepter C18 / HD-C18............................................A-16 Shim-pack GIS/GIS-HP C18......................................................A-44

Stronger Retentivity

Strong Retentivity of Highly Polar Compounds

Shim-pack GIST/GIST-HP C18-AQ............................................A-38

With Certificate of Compliance for Validation

Shim-pack VP-ODS..................................................................A-32

Shim-pack Scepter C18 / HD-C18 (pH range: 1 - 12).............A-16 Shim-pack GIST C18 (pH range: 1 - 10)..................................A-38

Wider pH Range

Shim-pack GIS C18..................................................................A-44 Shim-pack FC-ODS (pH range: 1.5 - 9)...................................A-67 Shim-pack Scepter HD C18.....................................................A-17

Stronger Retentivity

Conventional Analysis

Higher Steric Selectivity

Shim-pack GIS C18-P...............................................................A-46

Different Elution Pattern

Shim-pack GIS RP-Shield.........................................................A-48

Higher Cost-Performance

Shim-pack GWS C18................................................................A-49

Strong Retentivity of Basic Compounds

Shim-pack MAqC-ODS............................................................A-36

Pg A-3

Column Selection Guide

Column Selection by Target Compounds

Anion Exchange

High Polar Acid Compounds

Ion Exclusion

High Polar Neutral Compounds

Insoluble in Ethanol

Normal Phase

High Polar Basic Compounds

Cation Exchange

Soluble in Water

Mid-Polar Neutral Compounds

Soluble in Ethanol

Insoluble in Acid Water

Low Polar Acid Salts

Low Polar Basic Salts

Insoluble in Basic Water

Target Compounds

Reversed Phase

Low Polar Basic Compounds

Soluble in Acid Water

Low Polar Acid Compounds

Soluble in Basic Water

Insoluble in Water

Mid-Polar Neutral Compounds

Soluble in Ethanol

Normal Phase

Insoluble in Ethanol

Polymer Compounds

Size Exclusion

Column Selection by Target Compounds

Saturation Aliphatic Carboxylic Acids

Shim-pack Velox C18.......A-10 Shim-pack Scepter C18....A-16 Shim-pack GIST C18.........A.38

Reversed Phase

Non-saturation Aliphatic Carboxylic Acids

Aliphatic Carboxylic Acids

Shim-pack SCR-101H........A-96 Shim-pack SCR-102H........A-96

Ion Exclusion

Hydroxy and Keto Carboxylic Acids

Carboxylic Acids

Shim-pack IC-A1.............A-104 Shim-pack WAX-1............A-99

Anion Exchange

Shim-pack Velox C18.......A-10 Shim-pack Scepter C18....A-16 Shim-pack GIST C18.........A-38

Aromatic Carboxylic Acids

Reversed Phase

Pg A-4

Column Selection by Target Compounds

Shim-pack Scepter Dio-HILIC.................................A-21

HILIC Mode

Free Amino Acids

Shim-pack AMINO-LI.............................................A-95 (Post-column derivation fluorescing with OPA)

Cation Exchange

Shim-pack AMINO-NA...........................................A-95 (Post-column derivation fluorescing with OPA)

Cation Exchange

Amino Acids

Shim-pack Velox C18.............................................A-10 Shim-pack Scepter C18..........................................A-16 Shim-pack GIST C18...............................................A-38

Reversed Phase (Pre-column derivatization)

Protein-hydrolyzed Amino Acids

Shim-pack Velox C18.............................................A-10 Shim-pack Scepter C18..........................................A-16 Shim-pack GIST C18...............................................A-38

Reversed Phase + Ion Pair

Shim-pack Velox C18.............................................A-10 Shim-pack Scepter C18..........................................A-16 Shim-pack Arata Peptide C18...............................A-27 Shim-pack GIST C18...............................................A-38 Shim-pack GISS C18...............................................A-42

Peptides

Reversed Phase

Peptides Proteins

Shim-pack Scepter C4............................................A-22

Reversed Phase

Shim-pack Diol Series............................................A-85 Shim-pack Bio Diol.................................................A-77

Gel Filtration

Shim-pack Bio IEX SP/SP-NP...................................A-77 Shim-pack WCX-1..................................................A-99

Cation Exchange

Proteins

Shim-pack Bio IEX Q/Q-NP.....................................A-77 Shim-pack WAX-2..................................................A-99

Anion Exchange

Hydrophobic Interaction

Shim-pack Bio HIC................................................A-133

Shim-pack GIST NH2..............................................A-60

HILIC Mode

Monosaccharides

Gel Filtration + Ligand Exchange

Shim-pack SCR-101N/C/P........................................A-96

Mono- to tri-saccharides

Shim-pack ISA-07...................................................A-97

Anion Exchange

Sugars

Oligosaccharides

Shim-pack GIST NH2..............................................A-60

HILIC Mode

Shim-pack Velox C18.............................................A-10 Shim-pack Scepter C18..........................................A-16 Shim-pack GIST C18...............................................A-38

Derivatized Sugars

Reversed Phase

Pg A-5

Column Selection Guide

Column Selection by Target Compounds

Shim-pack Velox C18/SP-C18......A-10 Shim-pack Scepter......................A-16 Shim-pack GIST C18....................A-38

Mixture of Water-soluble / Fat-soluble vitamins

Reversed Phase

Vitamin C

Shim-pack GIST NH2...................A-60

HILIC Mode

Water-soluble Vitamins

Shim-pack Scepter C18...............A-16 Shim-pack MAqC-ODS................A-36

Reversed Phase

Vitamins

Others

HILIC Mode

Shim-pack Scepter Dio-HILIC......A-21

Shim-pack Velox..........................A-10 Shim-pack Scepter C18...............A-16 Shim-pack GIST C18....................A-38

Vitamin A, K

Reversed Phase

Fat-soluble Vitamins

Shim-pack GIST NH2...................A-60

Vitamin D, E

Normal Phase

Fat-soluble Vitamins

Water-soluble Vitamins

UV (325 nm) RF (Ex. 340 nm, Em. 460 nm)

UV (270 nm) RF (Post-column derivatization) UV (270 nm) RF (Post-column derivatization)

Vitamin A (retinol)

Vitamin B1 (thiamin)

Vitamin D

UV (265 nm)

Vitamin B2 (riboflavin)

UV (295 nm) RF (Ex. 295 nm, Em. 325 nm) UV (250 nm) RF (Post-column derivatization)

Vitamin E (tocopherol)

Vitamin B3 (niacin)

UV (260 nm) UV (205 nm) UV (290 nm) UV (280 nm) UV (210 nm) RI UV (245 nm) UV (210 nm) UV (280 nm) UV (265 nm)

Vitamin B5 (pantothenic acid)

Vitamin K

Vitamin B6 (pyridoxine)

Vitamin B12 (cyanocobalamine)

Vitamin BT (carnitine)

Vitamin C (ascorbic acid)

Vitamin H (biotin)

Vitamin M (folic acid) Vitamin P (hesperidin)

* The above wavelength values are approximate values. It is possible to be influenced by the state of mobile phase.

Shim-pack Bio IEX SP-NP/SP........A-77 Shim-pack WCX-1.......................A-99

Cation Exchange

Shim-pack Velox C18/SP-C18......A-10 Shim-pack Scepter C18/HD-C18..A-16 Shim-pack GIST C18....................A-38 Shim-pack Velox HILIC................A-13 Shim-pack Scepter Diol HILIC.....A-21 Shim-pack GIS HILIC....................A-58

Reversed Phase

Nucleic Acid Bases and Nucleosides

HILIC Mode

Shim-pack Bio IEX Q/Q-NP..........A-77 Shim-pack WAX-1.......................A-99

Anion Exchange

Nucleic Acids

Nucleotides

Shim-pack Velox..........................A-10 Shim-pack Scepter C18...............A-16 Shim-pack GIST C18....................A-38

Reversed Phase

Gel Filtration

Shim-pack Bio Diol......................A-77 Shim-pack Diol Series.................A-85

DNA and RNA

Shim-pack Bio IEX Q/Q-NP..........A-77 Shim-pack WAX-2.......................A-99

Anion Exchange

Pg A-6

Selection by USP

USP Code

Shim-pack HPLC Columns

Packing

Page

A-10 A-11 A-16 A-17 A-25 A-28 A-30 A-30 A-32 A-38 A-40 A-42 A-44 A-46 A-48 A-49 A-66 A-67 A-90 A-88

Shim-pack Velox C18 Shim-pack Velox SP-C18 Shim-pack Scepter C18 Shim-pack Scepter HD-C18 Shim-pack Arata C18 Shim-pack XR-ODS Shim-pack XR-ODS II Shim-pack XR-ODS III Shim-pack VP-ODS Shim-pack GIST C18 Shim-pack GIST C18-AQ

L1 Octadecyl silane chemically bonded to porous or non-porous silica or ceramic micro-particles, 1.5 to 10 µm in diameter, or a monolithic rod.

Shim-pack GISS C18 Shim-pack GIS C18

Shim-pack GIS C18-P Shim-pack GIS RP-Shield Shim-pack GWS C18 Shim-pack Solar C18

Shim-pack FC-ODS Shim-pack UC GIS II Mastro2™ C18 ULTRON VX-ODS

A-116 A-119 A-120

STR ODS-II STR ODS-M

A-13 A-28 A-90 A-91

Shim-pack Velox HILIC

Shim-pack XR-SIL Shim-pack UC Sil Shim-pack UC Sil II

L3

Porous silica particles, 1.5 to 10 µm in diameter, or a monolithic silica rod.

A-115

ULTRON VX-SIL

A-18 A-28 A-33 A-50 A-66

Shim-pack Scepter C8 Shim-pack XR-C8 Shim-pack VP-C8 Shim-pack GIST C8 Shim-pack Solar C8 ULTRON VX-Octyl Shim-pack GIST NH2 Shim-pack UC NH2 Shim-pack GIS CN Shim-pack UC CN

L7 Octylsilane chemically bonded to totally or superficially porous silica particles, 1.5 to 10 µm in diameter, or a monolithic silica rod.

A-117

A-60 A-90 A-64 A-90 A-12 A-20 A-28 A-32 A-52 A-54 A-90 A-96

L8 An essentially monomolecular layer of aminopropylsilane chemically bonded to totally porous silica gel support, 1.5 to 10 µm in diameter, or a monolithic silica rod.

L10 Nitrile groups chemically bonded to porous silica particles, 1.5 to 10 µm in diameter, or a monolithic silica rod.

Shim-pack Velox Biphenyl Shim-pack Scepter Phenyl Shim-pack XR-Phenyl Shim-pack VP-Phenyl Shim-pack GIST Phenyl Shim-pack GIST Phenyl-Hexyl

L11 Phenyl groups chemically bonded to porous silica particles, 1.5 to 10 µm in diameter, or a monolithic silica rod.

Shim-pack UC Phenyl Shim-pack SCR-101H

L17 Strong cation-exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the hydrogen form, 6 to 12 µm in diameter. L19 Strong cation-exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the calcium form, 5 - 15 µm in diameter.

A-105

ULTRON PS-80H

A-96

Shim-pack SCR-101C

A-113

ULTRON PS-80C

Shim-pack Scepter Diol-HILIC A-21 Shim-pack GIS HILIC A-58 Shim-pack UC Diol A-90 Shim-pack UC Diol II A-91 Shim-pack Diol-150 A-85 Shim-pack Diol-300 A-85 Shim-pack Bio Diol A-77

L20 Dihydroxypropane groups chemically bonded to porous silica or hybrid particles, 1.5 to 10 µm in diameter, or a monolithic silica rod.

A rigid, spherical styrene-divinylbenzene copolymer, 3 to 30 µm in diameter.

A-83

L21

Shim-pack GPC Series

A-101

Shim-pack IC-C1

A-95 A-95 A-97

Shim-pack AMINO-LI Shim-pack AMINO-NA

L22 A cation-exchange resin made of porous polystyrene gel with sulfonic acid groups, 5 - 15 µm in diameter.

Shim-pack ISC Shim-pack IC-A1

L23 An anion-exchange resin made of porous polymethacrylate or polyacrylate gel with quartenary ammonium groups, 7 - 12 µm in size.

A-104

Butyl silane chemically bonded to totally porous silica particles, 1.5 to 10 μm in diameter.

A-22

L26

Shim-pack Scepter C4

L33 Packing having the capacity to separate dextrans by molecular size over a range of 4,000 to 500,000 Da. It is spherical, silica-based, and processed to provide pH stability. L34 Strong cation exchange resin consisting of sulfonated crosslinked styrene-divinylbenzene copolymer in the lead form, 9μm in diameter.

A-77

Shim-pack Bio Diol

A-113

ULTRON PS-80P

A-12 A-19 A-56 A-88

Shim-pack Velox PFPP Shim-pack Scepter PFPP Shim-pack GIST PFPP Mastro2™ PFP ULTRON ES-CD ULTRON ES-PhCD ULTRON ES-OVM Shim-pack SCR-101N

L43 Pentafluorophenyl groups chemically bonded to silica particles by a propyl spacer, 1.5 to 10 μm in diameter.

A-112 A-112 A-110

Beta cyclodextrin bonded to porous silica particles, 5 to 10 μm in diameter.

L45

L57 A chiral-recognition protein, ovomucoid, chemically bonded to silica particles, about 5 μm in diameter, with a pore size of 120 Å.

A-96

L58 Strong cation-exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the sodium form, about 6 to 30 µm diameter.

A-113

ULTRON PS-80N

A-85 A-85 A-77

Shim-pack Diol-150 Shim-pack Diol-300 Shim-pack Bio Diol

L59 Packing for the size-exclusion separations of proteins (separation by molecular weight) over the range of 5 to 7000 kDa. The packing is spherical 1.5 - 10 µm, silica or hybrid packing with a hydrophilic coating. L68 Spherical, porous silica, 10 μm or less in diameter, the surface of which has been covalently modified with alkyl amide groups and not endcapped. L101 Cholesteryl groups bonded to porous or non-porous silica or ceramic micro-particles, 1.5 to 10 μm in diameter, or a monolithic rod.

A-62

Shim-pack GIST Amide

A-91 A-91

Shim-pack UC-Choles Shim-pack UC-Triazole

Triazole groups chemically bonded to porous silica particles, 1.5 to 10 μm in diameter.

L104

Pg A-7

Core Shell Columns

Maximize LC Separation Performance with Core Shell Technology

Designed to maximize performance of LC systems, Shimadzu’s Shim-pack Velox columns with core shell technology enable you to achieve increased separations and faster analysis times on any LC platform. Whether developing a high efficiency LC separation method, transferring an existing method for increased throughput while maintaining resolution, or are trying to improve the resolution of a complex separation, Shim-pack Velox columns will satisfy your needs. Column ruggedness is critical to any LC analysis and Shim-pack Velox core-shell columns deliver excellent column lifetime for even the most challenging sample matrices.

Shim-pack Velox column will deliver Increased resolution with maximum efficiency g improving separation and detection Faster separation without sacrificing performance g maximizing laboratory productivity and reducing cost of analysis Increased sample throughput g reducing overall analysis time Superior ruggedness g reducing cost of analysis Excellent reproducibility g maintaining analysis and data integrity Column Selection Guide for Different LC Platforms Column particle sizes and column volumes affect chromatography results significantly if the column configuration does not match the LC system. As column particle size is reduced, or the column volume (ID and/or the length of the columns) decreases, the necessity for a lower dispersion system is increased. Choosing the optimal column configuration for your LC system allows you to achieve improved chromatography. The following table summarizes the starting recommendations of column configuration for each LC system.

Prominence

Prominence-i plus

Nexera XR

Nexera-i plus

Nexera X2

LC System

HPLC

UHPLC-like

UHPLC

Particle size Column I.D.

2.7 µm & 5 µm

2.7 µm

1.8 µm & 2.7 µm

4.6 mm (3.0 mm)

3.0 mm (2.1 mm)

2.1 mm 150 mm

Column Length

100-250 mm

50-100 mm

Pg A-8

Column Chemistries Combining highly efficient core shell particle technology with a wide range of surface chemistries provides you with the best opportunity for optimal resolution. With different chemistry characteristics, Shim-pack Velox columns are suitable for use in a wide variety of applications and challenging separations.

SP-C18

C18

Biphenyl

PFPP

HILIC

USP Classification

L1

L1

L11

L43

L3

Sterically protected C18

Pentafluorophenyl propyl

Ligand type

C18

Biphenyl

None

Particle Size (µm)

1.8, 2.7, 5

1.8, 2.7, 5

1.8, 2.7, 5

1.8, 2.7, 5

2.7

Pore size (Å)

90

90

90

90

90

125 m 2 /g 130 m 2 /g 100 m 2 /g

125 m 2 /g 130 m 2 /g 100 m 2 /g

125 m 2 /g 130 m 2 /g 100 m 2 /g

125 m 2 /g 130 m 2 /g 100 m 2 /g

-

1.8 µm 2.7 µm

130 m 2 /g

Suraface Area

- -

5 µm

1.8 µm 2.7 µm

7 % 7 % 5 %

9 % 7 % 5 % YES

7 % 7 % 5 % YES

4 % 4 % 3 %

Carbon Load

NA

5 µm

-

End-Cap

No

No

No

pH range

1.0-8.0

2.0-8.0

1.5-8.0

2.0-8.0

2.0-8.0

1.8 µm 2.7 µm

100 MPa*

100 MPa*

100 MPa*

100 MPa*

-

Max Pressure

60 MPa 40 MPa

60 MPa 40 MPa

60 MPa 40 MPa

60 MPa 40 MPa

60 MPa

5 µm

-

* For maximum lifetime, recommended maximum pressure for 1.8 µm particles is 80MPa.

Lot to Lot Reproducibility We understand that lot to lot consistent performance of columns is required to maximize your laboratory performance. From one lot to the next, every Shim-pack Velox column you purchase will perform consistently.

Compounds (50 ng/mL) 1. Cortisol 2. 11-Deoxycortisol 3. Estradiol 4. Boldenone 5. Testosterone 6. Androstenedione 7. Progesterone

Conditions

Column

: Shim-pack Velox Biphenyl 2.7 µm, 3.0×100 mm (P/N: 227-32016-03 )

Flow Rate

: 0.7 mL/min

Column Temp. : 30 °C Sample Dilulent : Initial mobile phase Injection Volume : 5 µL Mobile Phase A

: 0.1 % formic acid in water

Mobile Phase B

: 0.1 % formic acid in acetonitrile Gradient: 40 % B (0 min) 80 % B (3 min)

Pg A-9

Core Shell Columns

Shim-pack Velox SP-C18 Designed and intended specifically for use under low pH condition, Shim-pack Velox SP (Sterically Protected)-C18 offers a well balanced retention profile with a long life time even under harsh, acidic condition needed for LC/MS(/MS) analysis.

Sterically protected to resist strongly acidic (pH 1-8) mobile phase condition Well balanced retention profile Suitable for LC/MS(/MS) analysis

Low pH Stability Sterically protected ligand provides extended low pH stability for the core shell particle. Shim-pack Velox SP-C18 columns maintain a stable retention profile under strongly acidic mobile phase condition (pH1) .

Conditions

Flow Rate

: 0.6 mL/min

Column Temp. Mobile Phase A Mobile Phase B

: 60 °C

: 0.1 % TFA in water

: Acetonitrile

: 45 % B (0 min – 7.5 min) g 5 % B (7.51 min – 50 min) 100 % B (55 min ) g 45 % B (55.01 min g 60 min)

Gradient

Shim-pack Velox SP-C18 Brand A FPP C18 Brand B FPP C18 Brand C FPP C18

Brand D Core-shell C18 Brand E Core-shell C18 Brand F Core-shell C18

Simultaneous Analysis of 22 Preservative Agents More than 20 compounds used as the preservative agent for industrial products like foods and cosmetics can can be separated by Shim-pack Velox SP-C18. The simultaneous determination and quantitation of multiple target compounds are possible in a wide range of commercial product within acceptable analytical times.

Preservative agents 1. 2-methyl-4-Isothiazolin-3-one 2. 2-Bromo-2-Nitro-1,3-propanediol 3. Salicylic Acid 4. Isothiazolinones 5. Benzoic Acid 6. Benzyl Alcohol 7. Sorbic Acid 8. 2-Phenoxyethanol 9. Methyl Paraben 10. Ethyl Paraben 11. Methyl Benzoate

12. Isopropyl Paraben 13. Propyl Paraben 14. 4-Chloro-3-Methylphenol 15. Ethyl Benzoate 16. Isobutyl 4-Hydroxybenzoate

17. Butyl Paraben 18. Chloroxylenol 19. Phenyl Benzoate 20. Clorofene 21. Triclocarban 22. Triclosan

LC Conditions

Column

: Shim-pack Velox SP-C18, 2.7 µm, 3.0×100 mm (PN: 227-32004-03)

Flow Rate

: 1.0 mL/min

Column Temp. Mobile Phase A Mobile Phase B

: 45 °C

: NaH2PO4 aq. (25 mM, pH3.8)

: MeOH/ACN = 9/1

: 8 %B (0 min ) g 30 % B (0.7 min – 2.7 min) 47 % B (2.71 min – 5min ) g 52 % B (6 min) 80 %B (7 min – 8 min) g 8 %B (9.01 min -10 min)

Gradient

Injection Volume : 1 µL Conc.

: 50 mg/L

Pg A-10

Shim-pack Velox SP-C18 Shim-pack Velox C18 is a traditional end-capped C18-bonded phase which offers the highest hydrophobic retention of any Shim-pack Velox phases and is applicable to a wide range of applications such as pharmaceutical, food, environmental and clinical and neutrals at moderately low and mid-range pH.

General purpose column for reversed-phase chromatography Highest hydrophobic retention among Shim-pack Velox series Compatible with moderately acidic to neutral mobile phases (pH 2-8)

Method Transfer for Cyanocobalamin Analysis within the USP Allowable Adjustment The assay of cyanocobalamin (a synthetic form of vitamin B12) with 5 µm fully-porous ODS column described in the USP monograph is transferred to a new method with Shim-pack Velox C18 2.7 µm column, within USP allowable adjustments. Analytical time and solvent consumption can be saved with transferred methods while meeting the requirements of system suitability.

USP requirement of Chromatography <621> When the column size is changed, the following conditions should be met; 1) L/dp ratio : within -25 % to +50 % or

Number of theoretical plates (N): within -25 % to +50 % (For SPP)

2) Flow rate : *Based on particle size and internal diameter and ±50% L : Column length dp : Particle size F : Flow rate dc : Internal diameter of the column * F 2 = F 1 × dc 2 2 × dp 1 dc 1 2 × dp 2

Original Method

Column

: Shim-pack VP-ODS (5 µm, 4.6×150 mm)

Flow rate

: 0.5 mL/min

Injection Volume : 100 µL Column temp. : 25 °C Detection

: UV 361 nm

Faster Method

Column

: Shim-pack Velox C18 (2.7 µm, 4.6×100 mm)

Flow rate

: 0.50 mL/min

Injection Volume : 67 µL Column temp. : 25 °C Detection

: UV 361 nm

Optimized Method Column

: Shim-pack Velox C18 (2.7 µm, 4.6×100 mm)

Flow rate

: 0.93 mL/min

Injection Volume : 67 µL Column temp. : 25 °C Detection

: UV 361 nm

System suitability test result (Requirement: %RSD < 2.0 %) tR: 0.025 % Area: 0.175 % (n=6) tR: 0.035 % Area: 0.103 % (n=6) tR: 0.084 % Area: 0.220 % (n=6)

Column

L/dp

Flow rate (mL/min)

N

VP-ODS (5 µm, 4.6×150 mm)

30,000

0.50

5,244

9,497 (+81 %) 4,466 (-15 %)

0.50

Velox C18 (2.7 µm, 4.6×100 mm)

37,037 (+23 %)

0.93

Pg A-11

Core Shell Columns

Shim-pack Velox Biphenyl Shim-pack Velox Biphenyl provides enhanced retention of aromatic compounds. It is useful for fast separations in bioanalytical applications due to the increased retention of early eluting analytes such as dipolar, unsaturated and conjugated analytes.

Complementary selectivity to alkyl phases Enhanced separation of aromatic compounds Ideal for increasing sensitivity and selectivity in LC/MS(/MS) analysis

Separating the Structural Isomers Even under the condition where 56 drugs of abuse and metabolites in human urine are quantitated within 10 minutes, two structural isomers, amobarmital and pentobarbital, which have been historically difficult to separate due to their similarity in chemical structures, could be relatively well resolved with shim-pack Velox Biphenyl column.

Amobarbital 5-ethyl-5-(3-methylbutyl)- 1,3-diazinane-2,4,6-trione

Pentobarbital 5-ethyl-5-pentan-2-yl-1,3- diazinane-2,4,6-trione

Conditions

System Column

: Nexera UHPLC System / LCMS-8050 : Shim-pack Velox Biphenyl 2.7 µm, 2.1 mm × 100 mm (PN: 227-32015-03)

Column Temp.

: 30 °C

Flow Rate

: 0.5 mL/min

Mobile Phase A Mobile Phase B

: 0.15 mM ammonium fluoride in water

: Methanol

Gradient : 20 % B (0 min) g 48 % B (1.5 min) g 53 % B (4 min) 100 %B (6 min - 7.5 min) g 20 % B (7.51 min - 9.5 min) Sample preparation : Enzymatically hydrolyzed human urine

was spiked with target compounds between 10 - 1000 % of the required cut off concentration. Samples were subsequently diluted 5x with 0.1 % formic acid.

Shim-pack Velox PFPP Shim-pack Velox PFPP (Pentafluorophenylpropyl) provides an alternative selectivity to C18 columns and is suitable for the analysis of halogenated compounds, positional isomers and charged bases.

Alternative selectivity to C18 columns Suitable for positional isomers and halogenated compounds Offers increased retention for charged bases

Good Separation of Cis / Trans Stilbene Cis and trans isomers of stilbene that are difficult to resolve with an ODS column due to their similarity in hydrophobicity can be well separated with Shim-pack Velox PFPP column.

1. cis-Stilbene

2. trans-Stilbene

LC Conditions

Column

: Shim-pack Velox PFPP, 2.7 µm, 3.0×100 mm (PN: 227-32022-04)

Column Temp.

: 40 °C

Flow Rate

: 0.4 mL/min

Mobile Phase

: Methanol/Water = 9/1

Detection

: UV 254 nm

Sample

: 1. cis-Stilbene, 2. trans-Stilbene

Injection Volume

: 1 µL

Pg A-12

Shim-pack Velox HILIC Hydrophilic interaction chromatography (HILIC) is an increasingly popular separation mode that can be used to improve the retention of challenging polar analytes. Shim-pack Velox HILIC using unbonded core shell particles is specifically designed for this application.

Orthogonal selectivity to reversed phase chromatography Increased retention of polar analytes Increased MS sensitivity Direct compatibility with sample preparation eluates

Retention of Nucleosides Nucleosides are polar molecules that are not well retained on reversed phase LC columns due to their hydrophilic nature are well retained and separated with Shim-pack Velox HILIC column.

1. Toluene 2. Uracil 3. Uridine 4. Adenosine 5. Guanosine 6. Cytidine

LC Conditions

Column

: Shim-pack Velox HILIC, 2.7 µm, 3.0×100 mm (PN: 227-32026-02)

Column Temp.

: 30 ºC

Flow Rate

: 0.4 mL/min

Mobile Phase

: Acetonitrile/20mM AcONH4aq.=9/1

Detection

: UV 254 nm

Sample

: 1. Toluene, 2. Uracil, 3. Uridine, 4. Adenosine, 5. Guanosine, 6. Cytidine

Injection Volume

: 1 µL

Shim-pack Velox 1.8 µm Columns

Chemistry

SP-C18

C18

Biphenyl

PFPP

I.D. (mm)

2.1

3.0

2.1

3.0

2.1

3.0

2.1

3.0

Length (mm)

30

227-32001-01

-

227-32007-01

-

227-32013-01

-

227-32019-01

-

50 227-32001-02 227-32002-01 227-32007-02 227-32008-01 227-32013-02 227-32014-01 227-32019-02 227-32020-01 100 227-32001-03 227-32002-02 227-32007-03 227-32008-02 227-32013-03 227-32014-02 227-32019-03 227-32020-02 150 227-32001-04 - 227-32007-04 - 227-32013-04 - 227-32019-04 -

Shim-pack Velox 2.7 µm Columns

Chemistry

SP-C18

C18

Biphenyl

I.D. (mm)

2.1

3.0

4.6

2.1

3.0

4.6

2.1

3.0

4.6

Length (mm)

30 227-32003-01 227-32004-01 227-32005-01 227-32009-01 227-32010-01 227-32011-01 227-32015-01 227-32016-01 227-32017-01 50 227-32003-02 227-32004-02 227-32005-02 227-32009-02 227-32010-02 227-32011-02 227-32015-02 227-32016-02 227-32017-02 100 227-32003-03 227-32004-03 227-32005-03 227-32009-03 227-32010-03 227-32011-03 227-32015-03 227-32016-03 227-32017-03 150 227-32003-04 227-32004-04 227-32005-04 227-32009-04 227-32010-04 227-32011-04 227-32015-04 227-32016-04 227-32017-04

Chemistry

PFPP

HILIC

I.D. (mm)

2.1

3.0

4.6

2.1

3.0

4.6

Length (mm)

30 50

227-32021-01 227-32022-01 227-32023-01 227-32025-01

-

-

227-32021-02 227-32022-02 227-32023-02 227-32025-02 227-32026-01 227-32027-01 227-32021-03 227-32022-03 227-32023-03 227-32025-03 227-32026-02 227-32027-02 227-32021-04 227-32022-04 227-32023-04 227-32025-04 227-32026-03 227-32027-03

100 150

Pg A-13

Core Shell Columns

Shim-pack Velox 5 µm Columns

Chemistry

SP-C18

C18

Biphenyl

PFPP

I.D. (mm)

4.6

Length (mm)

30 50

227-32006-01 227-32012-01 227-32018-01 227-32024-01 227-32006-02 227-32012-02 227-32018-02 227-32024-02 227-32006-03 227-32012-03 227-32018-03 227-32024-03 227-32006-04 227-32012-04 227-32018-04 227-32024-04

100 150

Shim-pack Velox EXP Guard Column Cartridge (3 pk)

Type

1.8 µm

2.7 µm

I.D. x L (mm)

SP-C18

C18

Biphenyl

PFPP

SP-C18

C18

Biphenyl

PFPP

HILIC

2.1 x 5 227-32028-01 227-32031-01 227-32034-01 227-32037-01 227-32029-01 227-32032-01 227-32035-01 227-32038-01 227-32040-01 3.0 x 5 227-32028-02 227-32031-02 227-32034-02 227-32037-02 227-32029-02 227-32032-02 227-32035-02 227-32038-02 227-32040-02 4.6 x 5 - - - - 227-32029-03 227-32032-03 227-32035-03 227-32038-03 227-32040-03

Type

5 μm

I.D. x L (mm)

SP-C18

C18

Biphenyl

PFPP

4.6 x 5

227-32030-01 227-32033-01 227-32036-01 227-32039-01

*Shim-pack Velox EXP Direct Connect Holder : 227-32041-01

Shim-pack Velox UHPLC Pre-column (0.2 μm)

1pc

227-32042-01

5pcs

227-32042-02

10pcs 227-32042-03 *For more pre-column options, please refer to page 110

Shim-pack Velox EXP Guard Column Free-turning architecture lets you change cartridges by hand without breaking inlet / outlet fluid connections — no tools needed. Guard column cartridges require Shim-pack Velox EXP Direct Connect Holder (227-32041-01)

Shim-pack Velox UHPLC Precolumn Filter (0.2 µm) To minimize extra column volume and maximize UHPLC sample throughput with SPE, SLE, or other sample preparation techniques, pair 1.8 µm Shim-pack Velox UHPLC columns with an Shim-pack Velox UHPLC Precolumn filter instead of a guard cartridge.

Pg A-14

UHPLC/HPLC Columns

Shim-pack Scepter LC Columns

Excellent stability & performance could be achieved under a wide range of LC conditions Excellent stability and performance could be achieved under a wide range of LC conditions with Shim-pack Scepter LC columns, which are the next generation organic silica hybrid based columns. With different chemistry characteristics, Shim-pack Scepter columns are effective for method development/scouting with suitability for use in a wide variety of applications. With different particle sizes (1.9 µm, 3 µm, 5 µm) and different column dimensions, Shim-pack Scepter LC columns are fully scalable between UHPLC, HPLC and preparative LC making method transfer seamless between different laboratory instrumentation.

Shim-pack Scepter Chemistries

Reversed Phase

HILIC

Shim-pack Scepter

C18

HD-C18

C8

Pheny

PFPP

C4

Diol-HILIC

Trifunctional C18 Trifunctional C18

Trifunctional Phenylbutyl

Trifunctional Pentafluorophenylpropyl

Trifunctional Dihydroxypropyl

Ligand Type

Trifunctional C8

Butyl group

Generic Purpose Type

High Density Type

Particle

Organic Silica Hybrid

Particle Size

1.9 μm, 3 μm, 5 μm

Pore Size

12 nm

8 nm

12 nm

30 nm

12 nm

End Capping

Proprietary

None

Proprietary

None

pH Range

1 - 12

1 - 10

1 - 8

1 - 10

2 - 10

100% aqueous condition

Yes

No

No

Yes

Yes

No

N/A

USP Classification

L1

L1

L7

L11

L43

L26

L20

Method Scouting Utilize excellent stability & performance under a wide range of LC conditions

With excellent stability under a wide range of LC conditions, Shim-pack Scepter LC columns are effective for method scouting combining mobile phase pH and organic modifier.

Comparison of Chromatograms using Gradient condition with Acetonitrile

Analytes 1. Saccharin (pKa = 2.2) 2. Dextromethorphan (pKa = 8.3) 3. Amitriptyline (pKa = 9.4) 4. N-Butyl paraben (pKa = 8.3) 5. Ibupurofen (pKa = 4.4)

For Shim-pack Scepter C4, please refer to page A-22

Pg A-15

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42 Page 43 Page 44 Page 45 Page 46 Page 47 Page 48 Page 49 Page 50 Page 51 Page 52 Page 53 Page 54 Page 55 Page 56 Page 57 Page 58 Page 59 Page 60 Page 61 Page 62 Page 63 Page 64 Page 65 Page 66 Page 67 Page 68 Page 69 Page 70 Page 71 Page 72 Page 73 Page 74 Page 75 Page 76 Page 77 Page 78 Page 79 Page 80 Page 81 Page 82 Page 83 Page 84 Page 85 Page 86 Page 87 Page 88 Page 89 Page 90 Page 91 Page 92 Page 93 Page 94 Page 95 Page 96 Page 97 Page 98 Page 99 Page 100 Page 101 Page 102 Page 103 Page 104 Page 105 Page 106 Page 107 Page 108 Page 109 Page 110 Page 111 Page 112 Page 113 Page 114 Page 115 Page 116 Page 117 Page 118 Page 119 Page 120 Page 121 Page 122 Page 123 Page 124 Page 125 Page 126 Page 127 Page 128 Page 129 Page 130 Page 131 Page 132 Page 133 Page 134 Page 135 Page 136 Page 137 Page 138 Page 139 Page 140 Page 141 Page 142 Page 143 Page 144 Page 145 Page 146 Page 147 Page 148 Page 149 Page 150 Page 151 Page 152 Page 153 Page 154 Page 155 Page 156 Page 157 Page 158 Page 159 Page 160 Page 161 Page 162 Page 163 Page 164 Page 165 Page 166 Page 167 Page 168 Page 169 Page 170 Page 171 Page 172 Page 173 Page 174 Page 175 Page 176 Page 177 Page 178 Page 179 Page 180 Page 181 Page 182 Page 183 Page 184 Page 185 Page 186 Page 187 Page 188 Page 189 Page 190 Page 191 Page 192 Page 193 Page 194 Page 195 Page 196 Page 197 Page 198 Page 199 Page 200

www.shopshimadzu.com

Made with FlippingBook Digital Proposal Creator