Consumables Digital Catalogue

Septums

Injection Port Septum

Description

P/N

Color

Description

Standard type (20 pcs)

• General-purpose septum • Maximum temperature (INJ setting temperature): 250 °C

201-35584

White

Provides signi cant durability improvements compared to a conventional low-bleed septum, offering both low bleed and long life. The problem of sticking to the vaporizing chamber during continuous use at high temperatures experienced with a conventional septum has also been eliminated. • Suitable for high-sensitivity analysis • Maximum temperature (INJ setting temperature): 450°C Using this septum alleviates the problem of reduced durability when the vaporizing chamber is used continuously at 450°C. Compared to the LL septum, the increase in bleed when used at high temperatures is kept at a lower level. The problem of sticking to the vaporizing chamber during continuous use at high temperatures experienced with a conventional septum has also been eliminated. • Suitable for high-sensitivity analysis at high temperatures • Maximum temperature (INJ setting temperature): 450°C

LL Septum (long life type, 20 pcs)

221-48972-91

Blue

HT Septum (high temp type, 20 pcs)

221-48398-91

Brown

Low-bleed Septum (25 pcs)

This septum is least in uenced by a plasticizer. Better prevents septum coring &

221-76650-01

Green

• Low-bleed, suitable for high-sensitivity analysis • Maximum temperature (INJ setting temperature): 340°C

Enduro Blue Septum (50 pcs)

• Low-bleed, suitable for high-sensitivity analysis at high temperatures • Maximum temperature (INJ setting temperature): 350°C

221-75180

Light Blue

Premium Green Septa (50 pcs)

• Low bleed, highly robust (max. usable temp. 350 °C ) • High durability, proper sealing and good resistance to most chemical solvents. • Useful for trace analysis and other applications where high sensitivity is critical

227-35004-01

Light green

Perforated septum for HS-10

• For HS-10 only • To ensure cleanliness and inertness • Maximum temperature (INJ setting temperature): 250 °C

221-76863-96

White

Low-bleed septum is not completely free of bleeding. The type of bleeding that occurs varies with the septum, and results in different patterns on chromatograms. In the case of high-sensitivity analysis, it is necessary to select a septum whose bleeding will not occur at a point that interferes with the peak of the target compound. Conditioning for several hours between 200°C and 250°C after extraction with hexane may help to reduce bleeding.

In the case of using a syringe for AOC, it is recommended to exchange the septum after about 100 injections. If the outside diameter of a needle of a gastight syringe is thick, it is recommended to exchange after about 50 injections.

Pg C-72