Manual Hydramax

STEP 3 Depending on the type you ordered, the bracket (listed as part 1 in the drawing below) will be included seperately in the set or already welded to the mounting plates of the roof. If you are using your own mounting plates, you need to weld these to the bracket (listed as part 1 in the drawing below) .

When assembling, please pay attention to the remarks in the frame below!

If you need to shorten the sliding bar, please make sure that the minimum distance between the bottom adapter and the tube is still larger than the lifting height of your lifting system! A

The spring-type pin (listed as part 2 in the drawing below) will block the hinge when installed, so please note the following:

B

ONLY mount the spring-type pin (listed as part 2 in the drawing below) if the structure is flexible and can move when lifting the roof, for example in case of lifting systems mounted in back pillars. These pillars can bend slightly when lifting the roof because the back doors are open. In this case, the hinges need to be blocked because otherwise there will be too much flexibility in the system. NEVER mount the spring-type pin (listed as part 2 in the drawing below) on the hinges of lifting systems that are fitted to fixed structures which can’t move when lifting the roof. This is for example the case with lifting systems installed to the front wall; since the front wall is not flexible, the hinges MUST NOT be blocked to prevent putting too much stress on the mechanical parts.

A

B

10

Made with FlippingBook - PDF hosting