S HUTDOWN PROCEDURES
Proper BRAHM ™ Collector shutdown is one of the key factors to achieving maximum filter cartridge
life.
To properly shutdown the BRAHM ™ Collector, simply depress the red “STOP” button.
If the BRAHM ™ Collector has reached a high enough pressure drop, the unit will begin to
cycle through its offline cleaning process. If the default settings are being used, this will take
about 3 to 14 minutes depending on the unit.
Always wait for the offline cleaning process to finish before disengaging the Power
Disconnect switch.
The blower will not stop immediately, and may take several minutes to fully stop.
The automatic cleaning system will continue to operate even if the red "STOP" button has
been depressed. This is normal and desirable; the offline cleaning is the most efficient
cleaning method.
Do NOT use the Power Disconnect switch to deactivate the unit unless it is an emergency
situation.
NOTE:
Do NOT shut down the Brahm™ Collector by disengaging the Power
Disconnect. If the Brahm™ Collector is shut down in this manner, it will
NOT perform offline cleaning and will diminish the life of the filter
cartridges.